This dataset includes a Microsoft Excel spreadsheet (*.xlsx file) provided as supplemental material for the NIST Technical Note (TN-2099) publication titled "Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed". The file contains two tabs, titled "Pre-Compensation" and "Post-Compensation", which provides example measurement data and calculations pertaining to the calibration procedures described in the publication. The spreadsheets also include multiple plots that are used to calculate fit lines, calibration constants, and calibration errors.
About this Dataset
Title | Calculation Sheet for Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed |
---|---|
Description | This dataset includes a Microsoft Excel spreadsheet (*.xlsx file) provided as supplemental material for the NIST Technical Note (TN-2099) publication titled "Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed". The file contains two tabs, titled "Pre-Compensation" and "Post-Compensation", which provides example measurement data and calculations pertaining to the calibration procedures described in the publication. The spreadsheets also include multiple plots that are used to calculate fit lines, calibration constants, and calibration errors. |
Modified | 2020-06-17 00:00:00 |
Publisher Name | National Institute of Standards and Technology |
Contact | mailto:[email protected] |
Keywords | Additive Manufacturing , Calibration , Galvanometer , Laser Powder Bed Fusion |
{ "identifier": "ark:\/88434\/mds2-2257", "accessLevel": "public", "contactPoint": { "hasEmail": "mailto:[email protected]", "fn": "Brandon Lane" }, "programCode": [ "006:045" ], "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-2257", "title": "Calculation Sheet for Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed", "description": "This dataset includes a Microsoft Excel spreadsheet (*.xlsx file) provided as supplemental material for the NIST Technical Note (TN-2099) publication titled \"Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed\". The file contains two tabs, titled \"Pre-Compensation\" and \"Post-Compensation\", which provides example measurement data and calculations pertaining to the calibration procedures described in the publication. The spreadsheets also include multiple plots that are used to calculate fit lines, calibration constants, and calibration errors.", "language": [ "en" ], "distribution": [ { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2257\/GalvoCalibrationCalculationSheet.xlsx.sha256", "mediaType": "text\/plain", "title": "SHA256 File for Calculation Sheet for Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2257\/GalvoCalibrationCalculationSheet.xlsx", "format": "Microsoft Excel Workbook (*.xlsx)", "description": "This dataset includes a Microsoft Excel spreadsheet (*.xlsx file) provided as supplemental material for the NIST Technical Note (TN-2099) publication titled \"Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed\". The file contains two tabs, titled \"Pre-Compensation\" and \"Post-Compensation\", which provides example measurement data and calculations pertaining to the calibration procedures described in the publication. The spreadsheets also include multiple plots that are used to calculate fit lines, calibration constants, and calibration errors.", "mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet", "title": "Calculation Sheet for Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed" }, { "accessURL": "https:\/\/doi.org\/10.18434\/M32257", "title": "DOI Access for Calculation Sheet for Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed" } ], "bureauCode": [ "006:55" ], "modified": "2020-06-17 00:00:00", "publisher": { "@type": "org:Organization", "name": "National Institute of Standards and Technology" }, "theme": [ "Manufacturing:Additive manufacturing" ], "keyword": [ "Additive Manufacturing", "Calibration", "Galvanometer", "Laser Powder Bed Fusion" ] }