Data from Influence of Fire on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase I

Six 2.7 m by 3.7 m shear wall specimens were fabricated consisting of 150 mm wide CFS framing sheathed on one side with sheet steel adhered to Type X gypsum board and on the opposite side with Type X gypsum board. The specimens were subjected sequentially to varied combinations of mechanical (shear) deformation and thermal (fire) loading. Specimen 1 (CFS01) was used to establish the monotonic 'pushover' load-displacement capacity of the wall system and subsequently to shake down the fire test setup. Specimen 2 (CFS02) was loaded by symmetric-amplitude reverse-cyclic shear deformation to destruction (defined here as 2.8 % drift ratio) to establish the cyclic load-displacement response. Specimen 3 and 4 (CFS03 and CFS04) were cycled to deformations just before and after the peak load was achieved, respectively, burned for 13 min and 20 s and then cycling was continued until destruction of the wall. For Specimen 5 (CFS05), an undamaged wall was exposed to fire for 13 min and 20 s and then cycled to destruction. Specimen 6 (CFS06) was tested similarly to Specimen 3, however, the burn duration was doubled.

The datasets include measured force, displacement and temperature data, as well as select videos.

About this Dataset

Updated: 2026-09-19
Metadata Last Updated: 2018-02-22 00:00:00
Date Created: N/A
Data Provided by:
Dataset Owner: N/A

Access this data

Contact dataset owner Access URL
Landing Page URL
Table representation of structured data
Title Data from Influence of Fire on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase I
Description Six 2.7 m by 3.7 m shear wall specimens were fabricated consisting of 150 mm wide CFS framing sheathed on one side with sheet steel adhered to Type X gypsum board and on the opposite side with Type X gypsum board. The specimens were subjected sequentially to varied combinations of mechanical (shear) deformation and thermal (fire) loading. Specimen 1 (CFS01) was used to establish the monotonic 'pushover' load-displacement capacity of the wall system and subsequently to shake down the fire test setup. Specimen 2 (CFS02) was loaded by symmetric-amplitude reverse-cyclic shear deformation to destruction (defined here as 2.8 % drift ratio) to establish the cyclic load-displacement response. Specimen 3 and 4 (CFS03 and CFS04) were cycled to deformations just before and after the peak load was achieved, respectively, burned for 13 min and 20 s and then cycling was continued until destruction of the wall. For Specimen 5 (CFS05), an undamaged wall was exposed to fire for 13 min and 20 s and then cycled to destruction. Specimen 6 (CFS06) was tested similarly to Specimen 3, however, the burn duration was doubled. The datasets include measured force, displacement and temperature data, as well as select videos.
Modified 2018-02-22 00:00:00
Publisher Name National Institute of Standards and Technology
Contact mailto:[email protected]
Keywords cold-formed steel; shear walls; earthquake; fire; fire following earthquake
{
    "identifier": "41709F592F4059B4E0531A570681F8C01510",
    "accessLevel": "public",
    "contactPoint": {
        "hasEmail": "mailto:[email protected]",
        "fn": "Matthew Hoehler"
    },
    "programCode": [
        "006:045"
    ],
    "landingPage": "https:\/\/data.nist.gov\/od\/id\/41709F592F4059B4E0531A570681F8C01510",
    "title": "Data from Influence of Fire on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase I",
    "description": "Six 2.7 m by 3.7 m shear wall specimens were fabricated consisting of 150 mm wide CFS framing sheathed on one side with sheet steel adhered to Type X gypsum board and on the opposite side with Type X gypsum board. The specimens were subjected sequentially to varied combinations of mechanical (shear) deformation and thermal (fire) loading. Specimen 1 (CFS01) was used to establish the monotonic 'pushover' load-displacement capacity of the wall system and subsequently to shake down the fire test setup. Specimen 2 (CFS02) was loaded by symmetric-amplitude reverse-cyclic shear deformation to destruction (defined here as 2.8 % drift ratio) to establish the cyclic load-displacement response. Specimen 3 and 4 (CFS03 and CFS04) were cycled to deformations just before and after the peak load was achieved, respectively, burned for 13 min and 20 s and then cycling was continued until destruction of the wall. For Specimen 5 (CFS05), an undamaged wall was exposed to fire for 13 min and 20 s and then cycled to destruction. Specimen 6 (CFS06) was tested similarly to Specimen 3, however, the burn duration was doubled. \n\nThe datasets include measured force, displacement and temperature data, as well as select videos.",
    "language": [
        "en"
    ],
    "distribution": [
        {
            "accessURL": "https:\/\/doi.org\/10.18434\/T4\/1422515",
            "format": "text\/html",
            "description": "DOI Access for Influence of FIre on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase 1",
            "title": "DOI Access for Influence of FIre on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase 1"
        }
    ],
    "bureauCode": [
        "006:55"
    ],
    "modified": "2018-02-22 00:00:00",
    "publisher": {
        "@type": "org:Organization",
        "name": "National Institute of Standards and Technology"
    },
    "theme": [
        "Buildings and Construction:Structural engineering",
        "Fire:Structural fire resistance",
        "Buildings and Construction:Building materials"
    ],
    "keyword": [
        "cold-formed steel; shear walls; earthquake; fire; fire following earthquake"
    ]
}