Six 2.7 m by 3.7 m shear wall specimens were fabricated consisting of 150 mm wide CFS framing sheathed on one side with sheet steel adhered to Type X gypsum board and on the opposite side with Type X gypsum board. The specimens were subjected sequentially to varied combinations of mechanical (shear) deformation and thermal (fire) loading. Specimen 1 (CFS01) was used to establish the monotonic 'pushover' load-displacement capacity of the wall system and subsequently to shake down the fire test setup. Specimen 2 (CFS02) was loaded by symmetric-amplitude reverse-cyclic shear deformation to destruction (defined here as 2.8 % drift ratio) to establish the cyclic load-displacement response. Specimen 3 and 4 (CFS03 and CFS04) were cycled to deformations just before and after the peak load was achieved, respectively, burned for 13 min and 20 s and then cycling was continued until destruction of the wall. For Specimen 5 (CFS05), an undamaged wall was exposed to fire for 13 min and 20 s and then cycled to destruction. Specimen 6 (CFS06) was tested similarly to Specimen 3, however, the burn duration was doubled.
The datasets include measured force, displacement and temperature data, as well as select videos.
About this Dataset
| Title | Data from Influence of Fire on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase I |
|---|---|
| Description | Six 2.7 m by 3.7 m shear wall specimens were fabricated consisting of 150 mm wide CFS framing sheathed on one side with sheet steel adhered to Type X gypsum board and on the opposite side with Type X gypsum board. The specimens were subjected sequentially to varied combinations of mechanical (shear) deformation and thermal (fire) loading. Specimen 1 (CFS01) was used to establish the monotonic 'pushover' load-displacement capacity of the wall system and subsequently to shake down the fire test setup. Specimen 2 (CFS02) was loaded by symmetric-amplitude reverse-cyclic shear deformation to destruction (defined here as 2.8 % drift ratio) to establish the cyclic load-displacement response. Specimen 3 and 4 (CFS03 and CFS04) were cycled to deformations just before and after the peak load was achieved, respectively, burned for 13 min and 20 s and then cycling was continued until destruction of the wall. For Specimen 5 (CFS05), an undamaged wall was exposed to fire for 13 min and 20 s and then cycled to destruction. Specimen 6 (CFS06) was tested similarly to Specimen 3, however, the burn duration was doubled. The datasets include measured force, displacement and temperature data, as well as select videos. |
| Modified | 2018-02-22 00:00:00 |
| Publisher Name | National Institute of Standards and Technology |
| Contact | mailto:[email protected] |
| Keywords | cold-formed steel; shear walls; earthquake; fire; fire following earthquake |
{
"identifier": "41709F592F4059B4E0531A570681F8C01510",
"accessLevel": "public",
"contactPoint": {
"hasEmail": "mailto:[email protected]",
"fn": "Matthew Hoehler"
},
"programCode": [
"006:045"
],
"landingPage": "https:\/\/data.nist.gov\/od\/id\/41709F592F4059B4E0531A570681F8C01510",
"title": "Data from Influence of Fire on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase I",
"description": "Six 2.7 m by 3.7 m shear wall specimens were fabricated consisting of 150 mm wide CFS framing sheathed on one side with sheet steel adhered to Type X gypsum board and on the opposite side with Type X gypsum board. The specimens were subjected sequentially to varied combinations of mechanical (shear) deformation and thermal (fire) loading. Specimen 1 (CFS01) was used to establish the monotonic 'pushover' load-displacement capacity of the wall system and subsequently to shake down the fire test setup. Specimen 2 (CFS02) was loaded by symmetric-amplitude reverse-cyclic shear deformation to destruction (defined here as 2.8 % drift ratio) to establish the cyclic load-displacement response. Specimen 3 and 4 (CFS03 and CFS04) were cycled to deformations just before and after the peak load was achieved, respectively, burned for 13 min and 20 s and then cycling was continued until destruction of the wall. For Specimen 5 (CFS05), an undamaged wall was exposed to fire for 13 min and 20 s and then cycled to destruction. Specimen 6 (CFS06) was tested similarly to Specimen 3, however, the burn duration was doubled. \n\nThe datasets include measured force, displacement and temperature data, as well as select videos.",
"language": [
"en"
],
"distribution": [
{
"accessURL": "https:\/\/doi.org\/10.18434\/T4\/1422515",
"format": "text\/html",
"description": "DOI Access for Influence of FIre on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase 1",
"title": "DOI Access for Influence of FIre on the Lateral Resistance of Cold-Formed Steel Shear Walls - Phase 1"
}
],
"bureauCode": [
"006:55"
],
"modified": "2018-02-22 00:00:00",
"publisher": {
"@type": "org:Organization",
"name": "National Institute of Standards and Technology"
},
"theme": [
"Buildings and Construction:Structural engineering",
"Fire:Structural fire resistance",
"Buildings and Construction:Building materials"
],
"keyword": [
"cold-formed steel; shear walls; earthquake; fire; fire following earthquake"
]
}