U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Diffraction Data for SRM 660c

The data from this instrument consists of sets of measurements of Xray intensity as a function of diffraction angle. Almost all of it is collected using scintillator point detector with a graphite analyzer, and is stored in CIF format.

About this Dataset

Updated: 2024-02-22
Metadata Last Updated: 2020-10-29 00:00:00
Date Created: N/A
Views:
Data Provided by:
Xray Powder Diffraction; Diverging Beam Diffractometer; Powder Diffraction SRM
Dataset Owner: N/A

Access this data

Contact dataset owner Download URL
Table representation of structured data
Title Diffraction Data for SRM 660c
Description The data from this instrument consists of sets of measurements of Xray intensity as a function of diffraction angle. Almost all of it is collected using scintillator point detector with a graphite analyzer, and is stored in CIF format.
Modified 2020-10-29 00:00:00
Publisher Name National Institute of Standards and Technology
Contact mailto:[email protected]
Keywords Xray Powder Diffraction; Diverging Beam Diffractometer; Powder Diffraction SRM
{
    "identifier": "ark:\/88434\/mds2-2315",
    "accessLevel": "public",
    "references": [
        "https:\/\/doi.org\/10.1017\/S0885715620000068"
    ],
    "contactPoint": {
        "hasEmail": "mailto:[email protected]",
        "fn": "David R. Black"
    },
    "programCode": [
        "006:045"
    ],
    "@type": "dcat:Dataset",
    "description": "The data from this instrument consists of sets of measurements of Xray intensity as a function of diffraction angle.  Almost all of it is collected using scintillator point detector with a graphite analyzer, and is stored in CIF format.",
    "language": [
        "en"
    ],
    "title": "Diffraction Data for SRM 660c",
    "distribution": [
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2315\/srm_660c_cifs_20201029_081700.zip.sha256",
            "mediaType": "text\/plain",
            "title": "SHA256 File for zip archive of CIF datasets from the SRM 660c certification"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2315\/srm_660c_cifs_20201029_081700.zip",
            "format": "zip file of IUCr Crystallographic Information File (CIF) datasets",
            "description": "These CIFs have the original data used to certify SRM660c, along with fits to the data indicative of how we processed it.  The fits are not the fits actually used in certification, since the models have been updated since then, but give essentially the same results.",
            "mediaType": "application\/zip",
            "title": "zip archive of CIF datasets from the SRM 660c certification"
        }
    ],
    "license": "https:\/\/www.nist.gov\/open\/license",
    "bureauCode": [
        "006:55"
    ],
    "modified": "2020-10-29 00:00:00",
    "publisher": {
        "@type": "org:Organization",
        "name": "National Institute of Standards and Technology"
    },
    "theme": [
        "Materials:Materials characterization"
    ],
    "issued": "2022-03-16",
    "keyword": [
        "Xray Powder Diffraction; Diverging Beam Diffractometer; Powder Diffraction SRM"
    ]
}

Was this page helpful?