Electromagnetic simulations of Parylene C devices, described in "The influence of intrinsic water and ion permeation of the dielectric properties of Parylene C films". We simulated various geometries of the device with different fluids inside and calculated S-parameters from extracted RLCG results. We also provide scripts to work up the simulation results into S-parameter plots.
About this Dataset
| Title | Electromagnetic simulations of Parylene C devices |
|---|---|
| Description | Electromagnetic simulations of Parylene C devices, described in "The influence of intrinsic water and ion permeation of the dielectric properties of Parylene C films". We simulated various geometries of the device with different fluids inside and calculated S-parameters from extracted RLCG results. We also provide scripts to work up the simulation results into S-parameter plots. |
| Modified | 2022-10-13 00:00:00 |
| Publisher Name | National Institute of Standards and Technology |
| Contact | mailto:[email protected] |
| Keywords | Parylene C , Microwave microfluidic spectroscopy , S-parameters , dielectric spectroscopy , profilometry , biomedical devices , implantable devices |
{
"identifier": "ark:\/88434\/mds2-2817",
"accessLevel": "public",
"contactPoint": {
"hasEmail": "mailto:[email protected]",
"fn": "Jacob Pawlik"
},
"programCode": [
"006:045"
],
"landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-2817",
"title": "Electromagnetic simulations of Parylene C devices",
"description": "Electromagnetic simulations of Parylene C devices, described in \"The influence of intrinsic water and ion permeation of the dielectric properties of Parylene C films\". We simulated various geometries of the device with different fluids inside and calculated S-parameters from extracted RLCG results. We also provide scripts to work up the simulation results into S-parameter plots.",
"language": [
"en"
],
"distribution": [
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2817\/Parylene%20C%20CPW%20Simulation%20resources%20for%20MIDAS.zip",
"mediaType": "application\/x-zip-compressed",
"title": "Electromagnetic simulations of Parylene C devices"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2817\/2817_README_edit.txt",
"description": "Added line in \"data use\" to indicate which programs are required to open the data",
"mediaType": "text\/plain",
"title": "README_edit"
}
],
"bureauCode": [
"006:55"
],
"modified": "2022-10-13 00:00:00",
"publisher": {
"@type": "org:Organization",
"name": "National Institute of Standards and Technology"
},
"theme": [
"Bioscience:Biomaterials",
"Electronics:Electromagnetics",
"Materials:Materials characterization",
"Physics:Spectroscopy"
],
"keyword": [
"Parylene C",
"Microwave microfluidic spectroscopy",
"S-parameters",
"dielectric spectroscopy",
"profilometry",
"biomedical devices",
"implantable devices"
]
}