The H3O+ PTR-MS PID Library is a collection of product ion distributions (PID) from volatile organic compounds measured from proton-transfer-reaction mass spectrometers (PTR-MS). This library contains PID measurements that PTR-MS users can use to understand possible measurement interferences. This library is intended to be updated with continued input from users. This library is a supplementary document to the manuscript "Product Ion Distributions using H3O+ PTR-ToF-MS: Mechanisms, Transmission Effects, and Instrument-to-Instrument Variability".
About this Dataset
Title | H3O+ PTR-MS PID Library |
---|---|
Description | The H3O+ PTR-MS PID Library is a collection of product ion distributions (PID) from volatile organic compounds measured from proton-transfer-reaction mass spectrometers (PTR-MS). This library contains PID measurements that PTR-MS users can use to understand possible measurement interferences. This library is intended to be updated with continued input from users. This library is a supplementary document to the manuscript "Product Ion Distributions using H3O+ PTR-ToF-MS: Mechanisms, Transmission Effects, and Instrument-to-Instrument Variability". |
Modified | 2024-10-02 00:00:00 |
Publisher Name | National Institute of Standards and Technology |
Contact | mailto:[email protected] |
Keywords | proton-transfer-reaction mass spectrometry , volatile organic compounds , product ion distributions , indoor air quality |
{ "identifier": "ark:\/88434\/mds2-3582", "accessLevel": "public", "contactPoint": { "hasEmail": "mailto:[email protected]", "fn": "Michael F. Link" }, "programCode": [ "006:045" ], "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-3582", "title": "H3O+ PTR-MS PID Library", "description": "The H3O+ PTR-MS PID Library is a collection of product ion distributions (PID) from volatile organic compounds measured from proton-transfer-reaction mass spectrometers (PTR-MS). This library contains PID measurements that PTR-MS users can use to understand possible measurement interferences. This library is intended to be updated with continued input from users. This library is a supplementary document to the manuscript \"Product Ion Distributions using H3O+ PTR-ToF-MS: Mechanisms, Transmission Effects, and Instrument-to-Instrument Variability\".", "language": [ "en" ], "distribution": [ { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3582\/H3O_PID_Library_V7.xlsx", "format": "Excel Spreadsheet", "mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet", "title": "H3O_PID_Library_V7" } ], "bureauCode": [ "006:55" ], "modified": "2024-10-02 00:00:00", "publisher": { "@type": "org:Organization", "name": "National Institute of Standards and Technology" }, "theme": [ "Chemistry:Analytical chemistry" ], "keyword": [ "proton-transfer-reaction mass spectrometry", "volatile organic compounds", "product ion distributions", "indoor air quality" ] }