We investigated the influence of the state of wear of Charpy machine anvils on test results by performing impact tests on NIST specimens of three energy levels with a machine equipped with new anvils (compliant with both ASTM E23 and ISO 148-2) and worn anvils (anvil corner radii and distance outside ASTM tolerances, but within ISO tolerances).
About this Dataset
| Title | Influence of machine anvil wear on Charpy test results |
|---|---|
| Description | We investigated the influence of the state of wear of Charpy machine anvils on test results by performing impact tests on NIST specimens of three energy levels with a machine equipped with new anvils (compliant with both ASTM E23 and ISO 148-2) and worn anvils (anvil corner radii and distance outside ASTM tolerances, but within ISO tolerances). |
| Modified | 2020-01-24 00:00:00 |
| Publisher Name | National Institute of Standards and Technology |
| Contact | mailto:[email protected] |
| Keywords | Absorbed energy , ASTM E23 , Charpy , ISO 148 , machine anvils , span , wear |
{
"identifier": "ark:\/88434\/mds2-2224",
"accessLevel": "public",
"contactPoint": {
"hasEmail": "mailto:[email protected]",
"fn": "Enrico Lucon"
},
"programCode": [
"006:045"
],
"landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-2224",
"title": "Influence of machine anvil wear on Charpy test results",
"description": "We investigated the influence of the state of wear of Charpy machine anvils on test results by performing impact tests on NIST specimens of three energy levels with a machine equipped with new anvils (compliant with both ASTM E23 and ISO 148-2) and worn anvils (anvil corner radii and distance outside ASTM tolerances, but within ISO tolerances).",
"language": [
"en"
],
"distribution": [
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20Low%20energy.csv.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for Data for low-energy specimens"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20High%20energy.csv.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for Data for high-energy specimens"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20Super-High%20energy.csv.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for Test results for super-high-energy specimens"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20Low%20energy.csv",
"format": "CSV file",
"description": "Test results for low-energy specimens, plus statistical analyses for the significance of the differences between new and worn anvils.",
"mediaType": "text\/csv",
"title": "Data for low-energy specimens"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20High%20energy.csv",
"format": "CSV file",
"description": "Test results for high-energy specimens, plus statistical analyses for the significance of the differences between new and worn anvils.",
"mediaType": "text\/csv",
"title": "Data for high-energy specimens"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20Super-High%20energy.csv",
"format": "CSV file",
"description": "Test results for super-high-energy specimens, plus statistical analyses for the significance of the differences between new and worn anvils.",
"mediaType": "text\/csv",
"title": "Test results for super-high-energy specimens"
},
{
"accessURL": "https:\/\/doi.org\/10.18434\/M32224",
"title": "DOI Access for Influence of machine anvil wear on Charpy test results"
}
],
"bureauCode": [
"006:55"
],
"modified": "2020-01-24 00:00:00",
"publisher": {
"@type": "org:Organization",
"name": "National Institute of Standards and Technology"
},
"theme": [
"Infrastructure",
"Materials:Metals",
"Materials:Materials characterization"
],
"keyword": [
"Absorbed energy",
"ASTM E23",
"Charpy",
"ISO 148",
"machine anvils",
"span",
"wear"
]
}