NIST Infiltration Correlations for DOE Prototype Commercial Buildings

This workbook accompanies two publications [1] Evaluating Potential Benefits of Air Barriers in Commercial Buildings using NIST Infiltration Correlations in EnergyPlus DOI: 10.1016/j.buildenv.2021.107783 and [2] Implementing NIST Correlations: https://doi.org/10.6028/NIST.TN.2221-upd1

About this Dataset

Updated: 2024-02-22
Metadata Last Updated: 2022-04-01 00:00:00
Date Created: N/A
Views:
Data Provided by:
CONTAM
Dataset Owner: N/A

Access this data

Contact dataset owner Landing Page URL
Download URL
Table representation of structured data
Title NIST Infiltration Correlations for DOE Prototype Commercial Buildings
Description This workbook accompanies two publications [1] Evaluating Potential Benefits of Air Barriers in Commercial Buildings using NIST Infiltration Correlations in EnergyPlus DOI: 10.1016/j.buildenv.2021.107783 and [2] Implementing NIST Correlations: https://doi.org/10.6028/NIST.TN.2221-upd1
Modified 2022-04-01 00:00:00
Publisher Name National Institute of Standards and Technology
Contact mailto:[email protected]
Keywords CONTAM , EnergyPlus , airflow modeling , building envelope airtightness , commercial buildings , energy modeling , infiltration
{
    "identifier": "ark:\/88434\/mds2-2598",
    "accessLevel": "public",
    "references": [
        "https:\/\/doi.org\/10.1016\/j.buildenv.2021.107783",
        "https:\/\/doi.org\/10.6028\/NIST.TN.2221-upd1"
    ],
    "contactPoint": {
        "hasEmail": "mailto:[email protected]",
        "fn": "Lisa Ng"
    },
    "programCode": [
        "006:045"
    ],
    "@type": "dcat:Dataset",
    "replaces": "ark:\/88434\/mds2-2598",
    "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-3046",
    "description": "This workbook accompanies two publications [1] Evaluating Potential Benefits of Air Barriers in Commercial Buildings using NIST Infiltration Correlations in EnergyPlus DOI: 10.1016\/j.buildenv.2021.107783 and [2] Implementing NIST Correlations: https:\/\/doi.org\/10.6028\/NIST.TN.2221-upd1",
    "language": [
        "en"
    ],
    "title": "NIST Infiltration Correlations for DOE Prototype Commercial Buildings",
    "distribution": [
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2598\/Data-InfiltrationInputs(FINAL).xlsx",
            "mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
            "title": "Data-InfiltrationInputs(FINAL)"
        }
    ],
    "license": "https:\/\/www.nist.gov\/open\/license",
    "bureauCode": [
        "006:55"
    ],
    "modified": "2022-04-01 00:00:00",
    "publisher": {
        "@type": "org:Organization",
        "name": "National Institute of Standards and Technology"
    },
    "accrualPeriodicity": "irregular",
    "theme": [
        "Buildings and Construction:Air conditioning and heating equipment",
        "Buildings and Construction:Indoor air quality",
        "Buildings and Construction:Building materials",
        "Environment:Environmental health",
        "Energy:Energy efficiency"
    ],
    "keyword": [
        "CONTAM",
        "EnergyPlus",
        "airflow modeling",
        "building envelope airtightness",
        "commercial buildings",
        "energy modeling",
        "infiltration"
    ]
}