This atlas presents observations of the infra-red (IR) spectrum of a low current Th-Ar hollow cathode lamp with the 2-m Fourier transform spectrometer (FTS) at NIST. These observations establish more than 2400 lines that are suitable for use as wavelength standards in the range 691 nm to 5804 nm. The observations were made in collaboration with the European Southern Observatory (ESO), in order to provide calibration reference data for new high-resolution Echelle spectrographs, such as the Cryogenic High-Resolution IR Echelle Spectrograph ([CRIRES]), ESO's new IR spectrograph at the Very Large Telescope in Chile.
About this Dataset
Title | NIST The Spectrum of Th-Ar Hollow Cathode Lamps - SRD 161 |
---|---|
Description | This atlas presents observations of the infra-red (IR) spectrum of a low current Th-Ar hollow cathode lamp with the 2-m Fourier transform spectrometer (FTS) at NIST. These observations establish more than 2400 lines that are suitable for use as wavelength standards in the range 691 nm to 5804 nm. The observations were made in collaboration with the European Southern Observatory (ESO), in order to provide calibration reference data for new high-resolution Echelle spectrographs, such as the Cryogenic High-Resolution IR Echelle Spectrograph ([CRIRES]), ESO's new IR spectrograph at the Very Large Telescope in Chile. |
Modified | 2011-12-13 00:00:00 |
Publisher Name | National Institute of Standards and Technology |
Contact | mailto:[email protected] |
Keywords | hollow cathode lamps , infra red , lamps , spectra |
{ "identifier": "FDB59097468D5200E043065706813E54149", "accessLevel": "public", "contactPoint": { "hasEmail": "mailto:[email protected]", "fn": "Gillian Nave" }, "programCode": [ "006:052" ], "landingPage": "https:\/\/www.nist.gov\/pml\/spectrum-th-ar-hollow-cathode-lamps", "title": "NIST The Spectrum of Th-Ar Hollow Cathode Lamps - SRD 161", "description": "This atlas presents observations of the infra-red (IR) spectrum of a low current Th-Ar hollow cathode lamp with the 2-m Fourier transform spectrometer (FTS) at NIST. These observations establish more than 2400 lines that are suitable for use as wavelength standards in the range 691 nm to 5804 nm. The observations were made in collaboration with the European Southern Observatory (ESO), in order to provide calibration reference data for new high-resolution Echelle spectrographs, such as the Cryogenic High-Resolution IR Echelle Spectrograph ([CRIRES]), ESO's new IR spectrograph at the Very Large Telescope in Chile.", "language": [ "en" ], "distribution": [ { "accessURL": "https:\/\/dx.doi.org\/10.18434\/T4S01V", "format": "text\/html", "description": "A persistent identifier to locate and access SRD 161- The Spectrum of Th-Ar Hollow Cathode Lamps in the 691 nm to 5804 nm region", "title": "DOI access NIST The Spectrum of Th-Ar Hollow Cathode Lamps - SRD 161" } ], "bureauCode": [ "006:55" ], "modified": "2011-12-13 00:00:00", "publisher": { "@type": "org:Organization", "name": "National Institute of Standards and Technology" }, "theme": [ "Standards:Reference data", "Physics:Spectroscopy" ], "keyword": [ "hollow cathode lamps", "infra red", "lamps", "spectra" ] }