We investigated the influence of the state of wear of Charpy machine anvils on test results by performing impact tests on NIST specimens of three energy levels with a machine equipped with new anvils (compliant with both ASTM E23 and ISO 148-2) and worn anvils (anvil corner radii and distance outside ASTM tolerances, but within ISO tolerances).
About this Dataset
Title | Influence of machine anvil wear on Charpy test results |
---|---|
Description | We investigated the influence of the state of wear of Charpy machine anvils on test results by performing impact tests on NIST specimens of three energy levels with a machine equipped with new anvils (compliant with both ASTM E23 and ISO 148-2) and worn anvils (anvil corner radii and distance outside ASTM tolerances, but within ISO tolerances). |
Modified | 2020-01-24 00:00:00 |
Publisher Name | National Institute of Standards and Technology |
Contact | mailto:[email protected] |
Keywords | Absorbed energy , ASTM E23 , Charpy , ISO 148 , machine anvils , span , wear |
{ "identifier": "ark:\/88434\/mds2-2224", "accessLevel": "public", "contactPoint": { "hasEmail": "mailto:[email protected]", "fn": "Enrico Lucon" }, "programCode": [ "006:045" ], "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-2224", "title": "Influence of machine anvil wear on Charpy test results", "description": "We investigated the influence of the state of wear of Charpy machine anvils on test results by performing impact tests on NIST specimens of three energy levels with a machine equipped with new anvils (compliant with both ASTM E23 and ISO 148-2) and worn anvils (anvil corner radii and distance outside ASTM tolerances, but within ISO tolerances).", "language": [ "en" ], "distribution": [ { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20Low%20energy.csv.sha256", "mediaType": "text\/plain", "title": "SHA256 File for Data for low-energy specimens" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20High%20energy.csv.sha256", "mediaType": "text\/plain", "title": "SHA256 File for Data for high-energy specimens" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20Super-High%20energy.csv.sha256", "mediaType": "text\/plain", "title": "SHA256 File for Test results for super-high-energy specimens" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20Low%20energy.csv", "format": "CSV file", "description": "Test results for low-energy specimens, plus statistical analyses for the significance of the differences between new and worn anvils.", "mediaType": "text\/csv", "title": "Data for low-energy specimens" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20High%20energy.csv", "format": "CSV file", "description": "Test results for high-energy specimens, plus statistical analyses for the significance of the differences between new and worn anvils.", "mediaType": "text\/csv", "title": "Data for high-energy specimens" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2224\/Influence%20anvil%20wear%20-%20Super-High%20energy.csv", "format": "CSV file", "description": "Test results for super-high-energy specimens, plus statistical analyses for the significance of the differences between new and worn anvils.", "mediaType": "text\/csv", "title": "Test results for super-high-energy specimens" }, { "accessURL": "https:\/\/doi.org\/10.18434\/M32224", "title": "DOI Access for Influence of machine anvil wear on Charpy test results" } ], "bureauCode": [ "006:55" ], "modified": "2020-01-24 00:00:00", "publisher": { "@type": "org:Organization", "name": "National Institute of Standards and Technology" }, "theme": [ "Infrastructure", "Materials:Metals", "Materials:Materials characterization" ], "keyword": [ "Absorbed energy", "ASTM E23", "Charpy", "ISO 148", "machine anvils", "span", "wear" ] }