Dataset for multiple publishable figures in the paper entitled "Quasi-continuous voltage standard using sinusoidal and pulse-driven Josephson junction arrays" submitted to Meas. Sci. and Tech. journal. Figure 3. (a) Pattern of pulses used to generate a dc voltage of 0.2 V, (b) difference from the nominal of the voltage measured using the K3458A versus dc bias current for different RF power biases.Figure 4. PD JJA voltage difference from nominal, measured with a K3458A, versus dc bias current for different pulse patterns and repetition frequencies.Figure 5. (a) Current-voltage characteristic of the CWD JJA and (b) the RF power-voltage characteristic of the PD JJA. The error bars show the Type-A uncertainty (k=1) of the measurement of five measurements.Figure 6. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.Figure 7. Allan deviation for 0 V. See text for details.Figure 8. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.Figure 9. Allan deviation at 1 V.
About this Dataset
Title | Quasi-continuous voltage standard using sinusoidal and pulse-driven Josephson junction arrays |
---|---|
Description | Dataset for multiple publishable figures in the paper entitled "Quasi-continuous voltage standard using sinusoidal and pulse-driven Josephson junction arrays" submitted to Meas. Sci. and Tech. journal. Figure 3. (a) Pattern of pulses used to generate a dc voltage of 0.2 V, (b) difference from the nominal of the voltage measured using the K3458A versus dc bias current for different RF power biases.Figure 4. PD JJA voltage difference from nominal, measured with a K3458A, versus dc bias current for different pulse patterns and repetition frequencies.Figure 5. (a) Current-voltage characteristic of the CWD JJA and (b) the RF power-voltage characteristic of the PD JJA. The error bars show the Type-A uncertainty (k=1) of the measurement of five measurements.Figure 6. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.Figure 7. Allan deviation for 0 V. See text for details.Figure 8. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.Figure 9. Allan deviation at 1 V. |
Modified | 2022-07-18 00:00:00 |
Publisher Name | National Institute of Standards and Technology |
Contact | mailto:[email protected] |
Keywords | Josephson arbitrary waveform synthesizer , Josephson junction , Josephson standards , programmable Josephson voltage standard , quantum electrical standards , voltage generation. |
{ "identifier": "ark:\/88434\/mds2-2720", "accessLevel": "public", "contactPoint": { "hasEmail": "mailto:[email protected]", "fn": "Samuel P. Benz" }, "programCode": [ "006:045" ], "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-2720", "title": "Quasi-continuous voltage standard using sinusoidal and pulse-driven Josephson junction arrays", "description": "Dataset for multiple publishable figures in the paper entitled \"Quasi-continuous voltage standard using sinusoidal and pulse-driven Josephson junction arrays\" submitted to Meas. Sci. and Tech. journal. Figure 3. (a) Pattern of pulses used to generate a dc voltage of 0.2 V, (b) difference from the nominal of the voltage measured using the K3458A versus dc bias current for different RF power biases.Figure 4. PD JJA voltage difference from nominal, measured with a K3458A, versus dc bias current for different pulse patterns and repetition frequencies.Figure 5. (a) Current-voltage characteristic of the CWD JJA and (b) the RF power-voltage characteristic of the PD JJA. The error bars show the Type-A uncertainty (k=1) of the measurement of five measurements.Figure 6. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.Figure 7. Allan deviation for 0 V. See text for details.Figure 8. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.Figure 9. Allan deviation at 1 V.", "language": [ "en" ], "distribution": [ { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig%206.csv", "format": "CSV", "description": "Current-voltage characteristic of the CW-JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.csv", "mediaType": "text\/csv", "title": "Fig 6 Current-voltage characteristic of the CW-JJAs" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig%207.csv", "format": "CSV", "description": "Fig. 7. Allan deviation for 0 V. See text for details. The straight lines show the weighted least squares fit to a straight line for the data points up to the knee of the curves", "mediaType": "text\/csv", "title": "Fig 7 Allan deviation for 0 V. See text for details" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig%208.csv", "format": "csv", "description": "Fig 8 Current voltage characteristic of the CW-JJAs. The errors bars show the Type A uncertainty (k=1) of the measurement.csv", "mediaType": "text\/csv", "title": "Fig 8 Current voltage characteristic of the CW-JJAs" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig%209.csv", "format": "csv", "description": "Fig. 9 Allan deviation at 1V", "mediaType": "text\/csv", "title": "Fig. 9 Allan deviation at 1V" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig3a.jpg", "format": "jpg", "description": "Pattern of pulses used to generate a dc voltage of 0.2 V", "mediaType": "image\/jpeg", "title": "Fig 3a" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig3b.jpg", "format": "jpg", "description": "difference from the nominal of the voltage measured using the K3458A versus dc bias current for different RF power biases. The error bars show the Type-A uncertainty (k=1) of the measurement.", "mediaType": "image\/jpeg", "title": "Fig 3b" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig4.jpg", "format": "jpg", "description": "PD JJA voltage difference from nominal, measured with a K3458A, versus dc bias current for different pulse patterns and repetition frequencies.", "mediaType": "image\/jpeg", "title": "Figure 4." }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig5a.jpg", "format": "jpg", "description": "Current-voltage characteristic of the CWD JJA and", "mediaType": "image\/jpeg", "title": "Figure 5 (a)" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig5b.jpg", "format": "jpg", "description": "the RF power-voltage characteristic of the PD JJA. The error bars show the Type-A uncertainty (k=1) of the measurement of five measurements.", "mediaType": "image\/jpeg", "title": "Frig 5b" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig6.jpg", "format": "jpg", "description": "Figure 6. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.", "mediaType": "image\/jpeg", "title": "Fig 6" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig7.jpg", "format": "jpg", "description": "Figure 7. Allan deviation for 0 V. See text for details.", "mediaType": "image\/jpeg", "title": "Fig 7" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig8.jpg", "format": "jpg", "description": "Figure 8. Current-voltage characteristic of the CWD JJAs. The error bars show the Type-A uncertainty (k=1) of the measurement.", "mediaType": "image\/jpeg", "title": "Fig 8" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig9.jpg", "format": "jpg", "description": "Allan deviation at 1 V.", "mediaType": "image\/jpeg", "title": "Figure 9" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/2720_README.txt", "format": "txt", "description": "This file describes the associated files and their data contained within the csv and jpg plots for the associated paper.", "mediaType": "text\/plain", "title": "Readme file describing the data" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig%203b.csv", "format": "CSV", "description": "Fig. 3b. Difference of the voltage measured using the K3458A from the nominal versus dc bias current for difference RF power bias. The error bars show the Type-A uncertainty (k=1) of the measurement.", "mediaType": "text\/csv", "title": "Fig. 3b. Difference of the voltage measured using the K3458A from the nominal versus dc bias current for difference RF power bias" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig%203a.csv", "format": "CSV", "description": "Pattern of pulses used to generate a dc voltage of 0.2 V.cvs", "mediaType": "text\/csv", "title": "Fig 3a Pattern of pulses used to generate a dc voltage of 0.2 V.cvs" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig%204.csv", "format": "CSV", "description": "PD-JJA voltage difference from nominal, measured with a K3458A, versus dc bias current for different pulse patterns and repetition frequencies", "mediaType": "text\/csv", "title": "Fig. 4. PD-JJA voltage difference from nominal" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig%205a.csv", "format": "CSV", "description": "Current-voltage characteristic of the CW-JJA", "mediaType": "text\/csv", "title": "Fig 5a Current-voltage characteristic of the CW-JJA" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2720\/Fig%205b.csv", "format": "CSV", "description": "#Fig. 5. (b) the RF power-voltage characteristic of the PD-JJA. The errors bars show the Type-A uncertainty (k=1) of the measurement of five measurements", "mediaType": "text\/csv", "title": "#Fig 5b the RF power-voltage characteristic of the PD-JJA" } ], "bureauCode": [ "006:55" ], "modified": "2022-07-18 00:00:00", "publisher": { "@type": "org:Organization", "name": "National Institute of Standards and Technology" }, "theme": [ "Standards:Reference instruments", "Electronics:Superconducting electronics" ], "keyword": [ "Josephson arbitrary waveform synthesizer", "Josephson junction", "Josephson standards", "programmable Josephson voltage standard", "quantum electrical standards", "voltage generation." ] }