U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Electrolytic Conductivity Measurements for Ten Ionic Liquids

Measured electrolytic conductivity data at a pressure of 0.1 MPa and for temperatures from 293.15 K to 323.15 K for the following 10 Ionic Liquids:1-benzyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-ethylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-butylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-hexylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-octylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-decylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-methyl-1-propylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amide1-butyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amide1-pentyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amide1-hexyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amideFor additional details, please see the associated publication: "Electrolytic Conductivity Measurements for Ten IonicLiquids," Journal of Ionic Liquids (publisher: Elsevier)https://www.sciencedirect.com/journal/journal-of-ionic-liquids [ISSN 2772-4220].Tables S1 and S2 in the associated publication contain the electrolyticconductivity measurements for 10 ionic liquids.

About this Dataset

Updated: 2025-04-06
Metadata Last Updated: 2022-03-31 00:00:00
Date Created: N/A
Data Provided by:
Dataset Owner: N/A

Access this data

Contact dataset owner Landing Page URL
Download URL
Table representation of structured data
Title Electrolytic Conductivity Measurements for Ten Ionic Liquids
Description Measured electrolytic conductivity data at a pressure of 0.1 MPa and for temperatures from 293.15 K to 323.15 K for the following 10 Ionic Liquids:1-benzyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-ethylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-butylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-hexylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-octylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-decylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-methyl-1-propylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amide1-butyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amide1-pentyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amide1-hexyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amideFor additional details, please see the associated publication: "Electrolytic Conductivity Measurements for Ten IonicLiquids," Journal of Ionic Liquids (publisher: Elsevier)https://www.sciencedirect.com/journal/journal-of-ionic-liquids [ISSN 2772-4220].Tables S1 and S2 in the associated publication contain the electrolyticconductivity measurements for 10 ionic liquids.
Modified 2022-03-31 00:00:00
Publisher Name National Institute of Standards and Technology
Contact mailto:[email protected]
Keywords electrolytic conductivity , measurements , ionic liquids
{
    "identifier": "ark:\/88434\/mds2-2724",
    "accessLevel": "public",
    "contactPoint": {
        "hasEmail": "mailto:[email protected]",
        "fn": "Joe W. Magee"
    },
    "programCode": [
        "006:045"
    ],
    "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-2724",
    "title": "Electrolytic Conductivity Measurements for Ten Ionic Liquids",
    "description": "Measured electrolytic conductivity data at a pressure of 0.1 MPa and for temperatures from 293.15 K to 323.15 K for the following 10 Ionic Liquids:1-benzyl-3-methylimidazolium bis[(trifluoromethane)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-ethylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-butylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-hexylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-octylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-[(4-methylphenyl)methyl]-3-decylimidazolium bis[(trifluoromethyl)sulfonyl]amide1-methyl-1-propylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amide1-butyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amide1-pentyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amide1-hexyl-1-methylpyrrolidinium bis[(trifluoromethyl)sulfonyl]amideFor additional details, please see the associated publication: \"Electrolytic Conductivity Measurements for Ten IonicLiquids,\" Journal of Ionic Liquids (publisher: Elsevier)https:\/\/www.sciencedirect.com\/journal\/journal-of-ionic-liquids [ISSN 2772-4220].Tables S1 and S2 in the associated publication contain the electrolyticconductivity measurements for 10 ionic liquids.",
    "language": [
        "en"
    ],
    "distribution": [
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2724\/EC_data.csv",
            "mediaType": "text\/csv"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2724\/EC_data.csv.sha256",
            "mediaType": "text\/plain"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2724\/README_ElecCondTenILsText_JoeMagee_2Nov2022.txt",
            "mediaType": "text\/plain"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2724\/README_ElecCondTenILsText_JoeMagee_2Nov2022.txt.sha256",
            "mediaType": "text\/plain"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2724\/Compound_map.csv",
            "mediaType": "text\/csv"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2724\/Compound_map.csv.sha256",
            "mediaType": "text\/plain"
        }
    ],
    "bureauCode": [
        "006:55"
    ],
    "modified": "2022-03-31 00:00:00",
    "publisher": {
        "@type": "org:Organization",
        "name": "National Institute of Standards and Technology"
    },
    "theme": [
        "Physics:Thermodynamics"
    ],
    "keyword": [
        "electrolytic conductivity",
        "measurements",
        "ionic liquids"
    ]
}