The data are measurements of test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz. Data includes S-parameter data (Ref_Cs_g25_HF_0.s2p, Ref_Rs_g25_HF_0.s2p, Ref_L1_g25_HF_0.s2p, Ref_S1_g25_HF_0.s2p, Ref_Rg_g25_HF_0.s2p, Ref_Og_g25_HF_0.s2p, Ref_L2_g25_HF_0.s2p, Ref_L3_g25_HF_0.s2p, Ref_L4_g25_HF_0.s2p, Ref_L5_g25_HF_0.s2p, Ref_L6_g25_HF_0.s2p, Ref_L7_g25_HF_0.s2p, Ref_L8_g25_HF_0.s2p, Ref_L9_g25_HF_0.s2p). Data is in an *.s2p format. The format is "# GHZ S RI R 50". Frequency is GHz, data is S-parameters as real and imaginary pairs to a reference impedance of 50 Ohms. The effective permittivity data is a frequency real part of permittivity and imaginary part of permittivity. The effective permittivity data is a frequency real part of characteristic impedance and imaginary part of characteristic impedance.
About this Dataset
Title | Test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz - Calnet |
---|---|
Description | The data are measurements of test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz. Data includes S-parameter data (Ref_Cs_g25_HF_0.s2p, Ref_Rs_g25_HF_0.s2p, Ref_L1_g25_HF_0.s2p, Ref_S1_g25_HF_0.s2p, Ref_Rg_g25_HF_0.s2p, Ref_Og_g25_HF_0.s2p, Ref_L2_g25_HF_0.s2p, Ref_L3_g25_HF_0.s2p, Ref_L4_g25_HF_0.s2p, Ref_L5_g25_HF_0.s2p, Ref_L6_g25_HF_0.s2p, Ref_L7_g25_HF_0.s2p, Ref_L8_g25_HF_0.s2p, Ref_L9_g25_HF_0.s2p). Data is in an *.s2p format. The format is "# GHZ S RI R 50". Frequency is GHz, data is S-parameters as real and imaginary pairs to a reference impedance of 50 Ohms. The effective permittivity data is a frequency real part of permittivity and imaginary part of permittivity. The effective permittivity data is a frequency real part of characteristic impedance and imaginary part of characteristic impedance. |
Modified | 2024-07-10 00:00:00 |
Publisher Name | National Institute of Standards and Technology |
Contact | mailto:[email protected] |
Keywords | on-wafer , S-parameter , 110 GHz , sapphire , multiline TRL , SOLT , series resistor , check standards , vector network analyzer , probes , impedance , propagation constant , Calnet |
{ "identifier": "ark:\/88434\/mds2-3404", "accessLevel": "public", "contactPoint": { "hasEmail": "mailto:[email protected]", "fn": "Nate Orloff" }, "programCode": [ "006:045" ], "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-3404", "title": "Test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz - Calnet", "description": "The data are measurements of test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz. Data includes S-parameter data (Ref_Cs_g25_HF_0.s2p, Ref_Rs_g25_HF_0.s2p, Ref_L1_g25_HF_0.s2p, Ref_S1_g25_HF_0.s2p, Ref_Rg_g25_HF_0.s2p, Ref_Og_g25_HF_0.s2p, Ref_L2_g25_HF_0.s2p, Ref_L3_g25_HF_0.s2p, Ref_L4_g25_HF_0.s2p, Ref_L5_g25_HF_0.s2p, Ref_L6_g25_HF_0.s2p, Ref_L7_g25_HF_0.s2p, Ref_L8_g25_HF_0.s2p, Ref_L9_g25_HF_0.s2p). Data is in an *.s2p format. The format is \"# GHZ S RI R 50\". Frequency is GHz, data is S-parameters as real and imaginary pairs to a reference impedance of 50 Ohms. The effective permittivity data is a frequency real part of permittivity and imaginary part of permittivity. The effective permittivity data is a frequency real part of characteristic impedance and imaginary part of characteristic impedance.", "language": [ "en" ], "distribution": [ { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3404\/V2.zip", "description": "Data includes S-parameter data (Ref_Cs_g25_HF_0.s2p, Ref_Rs_g25_HF_0.s2p, Ref_L1_g25_HF_0.s2p, Ref_S1_g25_HF_0.s2p, Ref_Rg_g25_HF_0.s2p, Ref_Og_g25_HF_0.s2p, Ref_L2_g25_HF_0.s2p, Ref_L3_g25_HF_0.s2p, Ref_L4_g25_HF_0.s2p, Ref_L5_g25_HF_0.s2p, Ref_L6_g25_HF_0.s2p, Ref_L7_g25_HF_0.s2p, Ref_L8_g25_HF_0.s2p, Ref_L9_g25_HF_0.s2p). Data is in an *.s2p format. The format is \"# GHZ S RI R 50\". Frequency is GHz, data is S-parameters as real and imaginary pairs to a reference impedance of 50 Ohms. The effective permittivity data is a frequency real part of permittivity and imaginary part of permittivity. The effective permittivity data is a frequency real part of characteristic impedance and imaginary part of characteristic impedance.", "mediaType": "application\/x-zip-compressed", "title": "Test S-parameter data for on-wafer calibrations from 10 MHz to 110 GHz" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3404\/3404_README.txt", "mediaType": "text\/plain" } ], "bureauCode": [ "006:55" ], "modified": "2024-07-10 00:00:00", "publisher": { "@type": "org:Organization", "name": "National Institute of Standards and Technology" }, "theme": [ "Advanced Communications:Wireless (RF)", "Electronics:Electromagnetics", "Electronics:Semiconductors", "Metrology:Electrical\/electromagnetic metrology" ], "keyword": [ "on-wafer", "S-parameter", "110 GHz", "sapphire", "multiline TRL", "SOLT", "series resistor", "check standards", "vector network analyzer", "probes", "impedance", "propagation constant", "Calnet" ] }