SRM 927g Bovine Serum Albumin (7% Solution) (Total Protein Standard) Data

Electronic files containing the certified value(s) and uncertainty(ies), and the data used to assign the value(s). Data are provided for amino acid analysis measurements that were used to determine the certified value for BSA concentration. Data for density measurements needed to convert mass fraction values to mass concentrations are also included. Biuret measurements were used to assign a non-certified value for total protein concentration.

About this Dataset

Updated: 2026-09-04
Metadata Last Updated: 2026-03-16 00:00:00
Date Created: N/A
Data Provided by:
Dataset Owner: N/A

Access this data

Contact dataset owner Landing Page URL
Download URL
Table representation of structured data
Title SRM 927g Bovine Serum Albumin (7% Solution) (Total Protein Standard) Data
Description Electronic files containing the certified value(s) and uncertainty(ies), and the data used to assign the value(s). Data are provided for amino acid analysis measurements that were used to determine the certified value for BSA concentration. Data for density measurements needed to convert mass fraction values to mass concentrations are also included. Biuret measurements were used to assign a non-certified value for total protein concentration.
Modified 2026-03-16 00:00:00
Publisher Name National Institute of Standards and Technology
Contact mailto:[email protected]
Keywords bovine serum albumin , total protein , amino acid analysis
{
    "identifier": "ark:\/88434\/mds2-4139",
    "accessLevel": "public",
    "contactPoint": {
        "hasEmail": "mailto:[email protected]",
        "fn": "Karen W. Phinney"
    },
    "programCode": [
        "006:045"
    ],
    "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-4139",
    "title": "SRM 927g Bovine Serum Albumin (7% Solution) (Total Protein Standard) Data",
    "description": "Electronic files containing the certified value(s) and uncertainty(ies), and the data used to assign the value(s). Data are provided for amino acid analysis measurements that were used to determine the certified value for BSA concentration. Data for density measurements needed to convert mass fraction values to mass concentrations are also included.  Biuret measurements were used to assign a non-certified value for total protein concentration.",
    "language": [
        "en"
    ],
    "distribution": [
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-4139\/927g_Readme.txt",
            "format": "text",
            "description": "927g Readme text file",
            "mediaType": "text\/plain",
            "title": "927g Readme"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-4139\/927g_DensityData_2025-06-23.xlsx",
            "format": "excel",
            "description": "Electronic file(s) containing the data used to assign value(s).",
            "mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
            "title": "927g Density Data"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-4139\/927g_all3setresults_corrected-for-intactMW%2CDensity_Data_2025-06-23.xlsx",
            "format": "excel",
            "description": "Electronic file(s) containing the data used to assign value(s).",
            "mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
            "title": "927g_AllSetResultsData"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-4139\/927g_Biuret_SED-Data_2025-06-23.xlsx",
            "format": "excel",
            "description": "Electronic file(s) containing the data used to assign value(s).",
            "mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
            "title": "927g_Biuret_SED_Data"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-4139\/927g_CertifiedValues_2026-03-16.xlsx",
            "format": "excel",
            "description": "Electronic file(s) containing the certified value(s) and uncertainty(ies).",
            "mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
            "title": "927g_CertifiedValues"
        }
    ],
    "bureauCode": [
        "006:55"
    ],
    "modified": "2026-03-16 00:00:00",
    "publisher": {
        "@type": "org:Organization",
        "name": "National Institute of Standards and Technology"
    },
    "theme": [
        "Standards:Reference materials"
    ],
    "keyword": [
        "bovine serum albumin",
        "total protein",
        "amino acid analysis"
    ]
}