3D Data for the Evaluation of Point-Based, Rigid Body Registration Error

Datasets to evaluate the performance of point-based, rigid-body registration may be downloaded from this site. Registration is the process of transforming one coordinate frame to another coordinate frame.

The datasets contain 3D position measurements obtained from three instruments: a laser tracker (LT), a motion capture system (System A), and a large-scale metrology system (System B). The positions are for points that are in a semi-regular, 5 x 5 x 5 grid. The grid covers a volume that is approximately (3 x 3 x 1.8) m [L x W x H]. The measurement uncertainties are ± 25e-03 mm for the laser tracker, ± 250e-03 mm for System B, while the accuracy of System A is only specified as sub-millimeter. The datasets for each instrument were collected in the instrument's local coordinate frame.

The datasets contain measurements of 125 fiducials (points used for registration) and 16 test points. Test points are points that are not used for registration but to which a transformation is applied; these points are used to evaluate the performance of the registration.

About this Dataset

Updated: 2026-09-19
Metadata Last Updated: 2017-03-02
Date Created: N/A
Data Provided by:
Dataset Owner: N/A

Access this data

Contact dataset owner Landing Page URL
Download URL
Table representation of structured data
Title 3D Data for the Evaluation of Point-Based, Rigid Body Registration Error
Description Datasets to evaluate the performance of point-based, rigid-body registration may be downloaded from this site. Registration is the process of transforming one coordinate frame to another coordinate frame. The datasets contain 3D position measurements obtained from three instruments: a laser tracker (LT), a motion capture system (System A), and a large-scale metrology system (System B). The positions are for points that are in a semi-regular, 5 x 5 x 5 grid. The grid covers a volume that is approximately (3 x 3 x 1.8) m [L x W x H]. The measurement uncertainties are ± 25e-03 mm for the laser tracker, ± 250e-03 mm for System B, while the accuracy of System A is only specified as sub-millimeter. The datasets for each instrument were collected in the instrument's local coordinate frame. The datasets contain measurements of 125 fiducials (points used for registration) and 16 test points. Test points are points that are not used for registration but to which a transformation is applied; these points are used to evaluate the performance of the registration.
Modified 2017-03-02
Publisher Name National Institute of Standards and Technology
Contact mailto:[email protected]
Keywords Coordinate transformation , registration fiducials , point-based registration , registration error.
{
    "identifier": "4A3BDFC9A11E4ECEE0531A570681E7481826",
    "accessLevel": "public",
    "contactPoint": {
        "hasEmail": "mailto:[email protected]",
        "fn": "Geraldine Cheok"
    },
    "programCode": [
        "006:045"
    ],
    "landingPage": "https:\/\/www.nist.gov\/el\/intelligent-systems-division-73500\/3d-data-evaluation-point-based-rigid-body-registration-error",
    "title": "3D Data for the Evaluation of Point-Based, Rigid Body Registration Error",
    "description": "Datasets to evaluate the performance of point-based, rigid-body registration may be downloaded from this site.  Registration is the process of transforming one coordinate frame to another coordinate frame.\n\nThe datasets contain 3D position measurements obtained from three instruments:  a laser tracker (LT), a motion capture system (System A), and a large-scale metrology system (System B).  The positions are for points that are in a semi-regular, 5 x 5 x 5 grid.  The grid covers a volume that is approximately (3 x 3 x 1.8) m [L x W x H].  The measurement uncertainties are \u00b1 25e-03 mm for the laser tracker, \u00b1 250e-03 mm for System B, while the accuracy of System A is only specified as sub-millimeter.  The datasets for each instrument were collected in the instrument's local coordinate frame.\n\nThe datasets contain measurements of 125 fiducials (points used for registration) and 16 test points.  Test points are points that are not used for registration but to which a transformation is applied; these points are used to evaluate the performance of the registration.",
    "language": [
        "en"
    ],
    "distribution": [
        {
            "downloadURL": "https:\/\/www.nist.gov\/file\/354986",
            "format": "CSV files",
            "description": "The datasets contain 3D position measurements obtained from three instruments:  a laser tracker (LT), a motion capture system (System A), and a large-scale metrology system (System B).  The positions are for points that are in a semi-regular, 5 x 5 x 5 grid.  The grid covers a volume that is approximately (3 x 3 x 1.8) m [L x W x H] .  The measurement uncertainties are \u00b1 25e-03 mm for the laser tracker, \u00b1 250e-03 mm for System B, while the accuracy of System A is only specified as sub-millimeter.  The datasets for each instrument were collected in the instrument's local coordinate frame.",
            "mediaType": "text\/csv",
            "title": "3D Data for the Evaluation of Point-Based, Rigid Body Registration Error"
        },
        {
            "accessURL": "https:\/\/doi.org\/doi:10.18434\/M39G6H"
        }
    ],
    "bureauCode": [
        "006:55"
    ],
    "modified": "2017-03-02",
    "publisher": {
        "@type": "org:Organization",
        "name": "National Institute of Standards and Technology"
    },
    "theme": [
        "Manufacturing: Robotics in manufacturing",
        "Health: Medical imaging"
    ],
    "keyword": [
        "Coordinate transformation",
        "registration fiducials",
        "point-based registration",
        "registration error."
    ]
}