We plan to present a technique for implementing a frequency doubler in NbTiN on silicon for operation in a cryogenic environment at IMS 2024. The kinetic inductance of a superconducting coplanar waveguide is exploited for efficient frequency conversion, while the fabrication allows for co-location with other cryogenic circuits. A conversion efficiency greater than 10% is demonstrated at a frequency of 9.87 GHz, offering lower input power requirements and competitive conversion efficiencies relative to other state-of-the-art solutions. This dataset contains information related to this presentation, specifically: (Fig. 2) Simulated conversion efficiency result, (Fig. 4) 2nd and 3rd order harmonic conversion efficiency data with input RF power ranging from (3 to 7), and (Fig. 5) second harmonic power as a function of dc bias current.
About this Dataset
| Title | Characterization of a Frequency Converter Based on a Superconducting Coplanar Waveguide, IMS 2024 |
|---|---|
| Description | We plan to present a technique for implementing a frequency doubler in NbTiN on silicon for operation in a cryogenic environment at IMS 2024. The kinetic inductance of a superconducting coplanar waveguide is exploited for efficient frequency conversion, while the fabrication allows for co-location with other cryogenic circuits. A conversion efficiency greater than 10% is demonstrated at a frequency of 9.87 GHz, offering lower input power requirements and competitive conversion efficiencies relative to other state-of-the-art solutions. This dataset contains information related to this presentation, specifically: (Fig. 2) Simulated conversion efficiency result, (Fig. 4) 2nd and 3rd order harmonic conversion efficiency data with input RF power ranging from (3 to 7), and (Fig. 5) second harmonic power as a function of dc bias current. |
| Modified | 2023-12-04 00:00:00 |
| Publisher Name | National Institute of Standards and Technology |
| Contact | mailto:[email protected] |
| Keywords | cryogenic electronics , frequency conversion , kinetic inductance , superconducting coils |
{
"identifier": "ark:\/88434\/mds2-3123",
"accessLevel": "public",
"contactPoint": {
"hasEmail": "mailto:[email protected]",
"fn": "Nathan Flowers-Jacobs"
},
"programCode": [
"006:045"
],
"landingPage": "",
"title": "Characterization of a Frequency Converter Based on a Superconducting Coplanar Waveguide, IMS 2024",
"description": "We plan to present a technique for implementing a frequency doubler in NbTiN on silicon for operation in a cryogenic environment at IMS 2024. The kinetic inductance of a superconducting coplanar waveguide is exploited for efficient frequency conversion, while the fabrication allows for co-location with other cryogenic circuits. A conversion efficiency greater than 10% is demonstrated at a frequency of 9.87 GHz, offering lower input power requirements and competitive conversion efficiencies relative to other state-of-the-art solutions. This dataset contains information related to this presentation, specifically: (Fig. 2) Simulated conversion efficiency result, (Fig. 4) 2nd and 3rd order harmonic conversion efficiency data with input RF power ranging from (3 to 7), and (Fig. 5) second harmonic power as a function of dc bias current.",
"language": [
"en"
],
"distribution": [
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3123\/Fig2.fig",
"format": "matlab figure",
"description": "(Fig. 2) Simulated conversion efficiency result (matlab figure)",
"mediaType": "application\/octet-stream",
"title": "(Fig. 2) Simulated conversion efficiency result (matlab figure)"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3123\/Fig4.fig",
"format": "matlab figure",
"description": "(Fig. 4) 2nd and 3rd order harmonic conversion efficiency data with input RF power ranging from (3 to 7) dBm (matlab figure)",
"mediaType": "application\/octet-stream",
"title": "(Fig. 4) 2nd and 3rd order harmonic conversion efficiency data with input RF power ranging from (3 to 7) dBm (matlab figure)"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3123\/Fig5.fig",
"format": "matlab figure",
"description": "(Fig. 5) measured and simulated second harmonic power as a function of dc bias current (matlab figure)",
"mediaType": "application\/octet-stream",
"title": "(Fig. 5) measured and simulated second harmonic power as a function of dc bias current (matlab figure)"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3123\/README.txt",
"format": "text file",
"description": "README for this data set, mds2-3123",
"mediaType": "text\/plain",
"title": "README"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3123\/Fig5_Sim.txt",
"mediaType": "text\/plain",
"title": "Fig5_Sim"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3123\/Fig4_Top.txt",
"mediaType": "text\/plain",
"title": "Fig4_Top"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3123\/Fig4_Bottom.txt",
"mediaType": "text\/plain",
"title": "Fig4_Bottom"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3123\/Fig2.txt",
"mediaType": "text\/plain",
"title": "Fig2"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3123\/Fig5_Measured.txt",
"mediaType": "text\/plain",
"title": "Fig5_Measured"
}
],
"bureauCode": [
"006:55"
],
"modified": "2023-12-04 00:00:00",
"publisher": {
"@type": "org:Organization",
"name": "National Institute of Standards and Technology"
},
"theme": [
"Electronics:Superconducting electronics"
],
"keyword": [
"cryogenic electronics",
"frequency conversion",
"kinetic inductance",
"superconducting coils"
]
}