The data are measurements of test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz. Data includes S-parameter data (Ref_Cs_g25_HF_0.s2p, Ref_Rs_g25_HF_0.s2p, Ref_L1_g25_HF_0.s2p, Ref_S1_g25_HF_0.s2p, Ref_Rg_g25_HF_0.s2p, Ref_Og_g25_HF_0.s2p, Ref_L2_g25_HF_0.s2p, Ref_L3_g25_HF_0.s2p, Ref_L4_g25_HF_0.s2p, Ref_L5_g25_HF_0.s2p, Ref_L6_g25_HF_0.s2p, Ref_L7_g25_HF_0.s2p, Ref_L8_g25_HF_0.s2p, Ref_L9_g25_HF_0.s2p). Data is in an *.s2p format. The format is "# GHZ S RI R 50". Frequency is GHz, data is S-parameters as real and imaginary pairs to a reference impedance of 50 Ohms. The effective permittivity data is a frequency real part of permittivity and imaginary part of permittivity. The effective permittivity data is a frequency real part of characteristic impedance and imaginary part of characteristic impedance.
About this Dataset
| Title | Test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz - Calnet |
|---|---|
| Description | The data are measurements of test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz. Data includes S-parameter data (Ref_Cs_g25_HF_0.s2p, Ref_Rs_g25_HF_0.s2p, Ref_L1_g25_HF_0.s2p, Ref_S1_g25_HF_0.s2p, Ref_Rg_g25_HF_0.s2p, Ref_Og_g25_HF_0.s2p, Ref_L2_g25_HF_0.s2p, Ref_L3_g25_HF_0.s2p, Ref_L4_g25_HF_0.s2p, Ref_L5_g25_HF_0.s2p, Ref_L6_g25_HF_0.s2p, Ref_L7_g25_HF_0.s2p, Ref_L8_g25_HF_0.s2p, Ref_L9_g25_HF_0.s2p). Data is in an *.s2p format. The format is "# GHZ S RI R 50". Frequency is GHz, data is S-parameters as real and imaginary pairs to a reference impedance of 50 Ohms. The effective permittivity data is a frequency real part of permittivity and imaginary part of permittivity. The effective permittivity data is a frequency real part of characteristic impedance and imaginary part of characteristic impedance. |
| Modified | 2024-07-10 00:00:00 |
| Publisher Name | National Institute of Standards and Technology |
| Contact | mailto:[email protected] |
| Keywords | on-wafer , S-parameter , 110 GHz , sapphire , multiline TRL , SOLT , series resistor , check standards , vector network analyzer , probes , impedance , propagation constant , Calnet |
{
"identifier": "ark:\/88434\/mds2-3404",
"accessLevel": "public",
"contactPoint": {
"hasEmail": "mailto:[email protected]",
"fn": "Nate Orloff"
},
"programCode": [
"006:045"
],
"landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-3404",
"title": "Test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz - Calnet",
"description": "The data are measurements of test scattering parameter calibration data for on-wafer measurements from 10 MHz to 110 GHz. Data includes S-parameter data (Ref_Cs_g25_HF_0.s2p, Ref_Rs_g25_HF_0.s2p, Ref_L1_g25_HF_0.s2p, Ref_S1_g25_HF_0.s2p, Ref_Rg_g25_HF_0.s2p, Ref_Og_g25_HF_0.s2p, Ref_L2_g25_HF_0.s2p, Ref_L3_g25_HF_0.s2p, Ref_L4_g25_HF_0.s2p, Ref_L5_g25_HF_0.s2p, Ref_L6_g25_HF_0.s2p, Ref_L7_g25_HF_0.s2p, Ref_L8_g25_HF_0.s2p, Ref_L9_g25_HF_0.s2p). Data is in an *.s2p format. The format is \"# GHZ S RI R 50\". Frequency is GHz, data is S-parameters as real and imaginary pairs to a reference impedance of 50 Ohms. The effective permittivity data is a frequency real part of permittivity and imaginary part of permittivity. The effective permittivity data is a frequency real part of characteristic impedance and imaginary part of characteristic impedance.",
"language": [
"en"
],
"distribution": [
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3404\/V2.zip",
"description": "Data includes S-parameter data (Ref_Cs_g25_HF_0.s2p, Ref_Rs_g25_HF_0.s2p, Ref_L1_g25_HF_0.s2p, Ref_S1_g25_HF_0.s2p, Ref_Rg_g25_HF_0.s2p, Ref_Og_g25_HF_0.s2p, Ref_L2_g25_HF_0.s2p, Ref_L3_g25_HF_0.s2p, Ref_L4_g25_HF_0.s2p, Ref_L5_g25_HF_0.s2p, Ref_L6_g25_HF_0.s2p, Ref_L7_g25_HF_0.s2p, Ref_L8_g25_HF_0.s2p, Ref_L9_g25_HF_0.s2p). Data is in an *.s2p format. The format is \"# GHZ S RI R 50\". Frequency is GHz, data is S-parameters as real and imaginary pairs to a reference impedance of 50 Ohms. The effective permittivity data is a frequency real part of permittivity and imaginary part of permittivity. The effective permittivity data is a frequency real part of characteristic impedance and imaginary part of characteristic impedance.",
"mediaType": "application\/x-zip-compressed",
"title": "Test S-parameter data for on-wafer calibrations from 10 MHz to 110 GHz"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3404\/3404_README.txt",
"mediaType": "text\/plain"
}
],
"bureauCode": [
"006:55"
],
"modified": "2024-07-10 00:00:00",
"publisher": {
"@type": "org:Organization",
"name": "National Institute of Standards and Technology"
},
"theme": [
"Advanced Communications:Wireless (RF)",
"Electronics:Electromagnetics",
"Electronics:Semiconductors",
"Metrology:Electrical\/electromagnetic metrology"
],
"keyword": [
"on-wafer",
"S-parameter",
"110 GHz",
"sapphire",
"multiline TRL",
"SOLT",
"series resistor",
"check standards",
"vector network analyzer",
"probes",
"impedance",
"propagation constant",
"Calnet"
]
}