Long term drift of the baseline-corrected, Voltage to Frequency conversion factor, observed in a Commercial-Off-the-Shelf Voltage-Controlled Crystal Oscillator.

Two column data of baseline-corrected sensitivity-drift (in units of PPM) of a Commercial-Off-the-Shelf VC/OCXO with respect to time (in units of years). The dataset spans about 0.7 years. Two spreadsheets are included in the workbook. The spreadsheet titled "Raw Data w. gaps 'as-collected'" contains the raw drift data, without any gap-filling. This shows the aging of a VC/OCXO's baseline-corrected sensitivity to constant input voltage. Text entries of "gap" in these numeric data arrays denote breaks in the data collection process attributable to other demands on the facility. The spreadsheet titled "Gap-filled data set" is needed for performing Allan variance analysis. Gaps in the data were mitigated by employing the technique outlined in D. A. Howe, C. Champagne and N. Schlossberger, "A Total Imputation Algorithm that Fills Gaps in Time Series Measurements for ADEV and Phase Noise Characterizations of Power-law Noise Models," 2022 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS), Paris, France, 2022, pp. 1-2, doi: 10.1109/EFTF/IFCS54560.2022.9850921.

About this Dataset

Updated: 2026-09-19
Metadata Last Updated: 2024-07-19 00:00:00
Date Created: N/A
Data Provided by:
Dataset Owner: N/A

Access this data

Contact dataset owner Landing Page URL
Download URL
Table representation of structured data
Title Long term drift of the baseline-corrected, Voltage to Frequency conversion factor, observed in a Commercial-Off-the-Shelf Voltage-Controlled Crystal Oscillator.
Description Two column data of baseline-corrected sensitivity-drift (in units of PPM) of a Commercial-Off-the-Shelf VC/OCXO with respect to time (in units of years). The dataset spans about 0.7 years. Two spreadsheets are included in the workbook. The spreadsheet titled "Raw Data w. gaps 'as-collected'" contains the raw drift data, without any gap-filling. This shows the aging of a VC/OCXO's baseline-corrected sensitivity to constant input voltage. Text entries of "gap" in these numeric data arrays denote breaks in the data collection process attributable to other demands on the facility. The spreadsheet titled "Gap-filled data set" is needed for performing Allan variance analysis. Gaps in the data were mitigated by employing the technique outlined in D. A. Howe, C. Champagne and N. Schlossberger, "A Total Imputation Algorithm that Fills Gaps in Time Series Measurements for ADEV and Phase Noise Characterizations of Power-law Noise Models," 2022 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF/IFCS), Paris, France, 2022, pp. 1-2, doi: 10.1109/EFTF/IFCS54560.2022.9850921.
Modified 2024-07-19 00:00:00
Publisher Name National Institute of Standards and Technology
Contact mailto:[email protected]
Keywords Component Aging , Voltage Metrology , Voltage Reference , Voltage Reference Drift , Voltage Reference Aging , Voltage Reference Validation , Quartz Crystal Oscillator , VCXO , VC/OCXO
{
    "identifier": "ark:\/88434\/mds2-3747",
    "accessLevel": "public",
    "contactPoint": {
        "hasEmail": "mailto:[email protected]",
        "fn": "Matthew Spidell"
    },
    "programCode": [
        "006:045"
    ],
    "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-3747",
    "title": "Long term drift of the baseline-corrected, Voltage to Frequency conversion factor, observed in a Commercial-Off-the-Shelf Voltage-Controlled Crystal Oscillator.",
    "description": "Two column data of baseline-corrected sensitivity-drift (in units of PPM)\u00a0of a Commercial-Off-the-Shelf VC\/OCXO with respect to time (in units of years). The dataset spans about 0.7 years. Two spreadsheets are included in the workbook. The spreadsheet titled \"Raw Data w. gaps 'as-collected'\" contains the raw drift data, without any gap-filling. This shows the aging of a VC\/OCXO's baseline-corrected sensitivity to constant input voltage. Text entries of \"gap\" in these numeric data arrays denote breaks in the data collection process attributable to other demands on the facility. The spreadsheet titled \"Gap-filled data set\" is needed for performing Allan variance analysis.\u00a0Gaps in the data were mitigated by employing the technique outlined in D. A. Howe, C. Champagne and N. Schlossberger, \"A Total Imputation Algorithm that Fills Gaps in Time Series Measurements for ADEV and Phase Noise Characterizations of Power-law Noise Models,\" 2022 Joint Conference of the European Frequency and Time Forum and IEEE International Frequency Control Symposium (EFTF\/IFCS), Paris, France, 2022, pp. 1-2, doi: 10.1109\/EFTF\/IFCS54560.2022.9850921.",
    "language": [
        "en"
    ],
    "distribution": [
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3747\/README.txt",
            "mediaType": "text\/plain",
            "title": "README"
        },
        {
            "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3747\/Simple%20Two%20Column%20VC-OCXO%20long%20term%20drift--gaps%20unfilled%20and%20filled--Releasable.xlsx",
            "mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
            "title": "Simple Two Column VC-OCXO long term drift--gaps unfilled and filled--Releasable"
        }
    ],
    "bureauCode": [
        "006:55"
    ],
    "modified": "2024-07-19 00:00:00",
    "publisher": {
        "@type": "org:Organization",
        "name": "National Institute of Standards and Technology"
    },
    "theme": [
        "Metrology:Electrical\/electromagnetic metrology"
    ],
    "keyword": [
        "Component Aging",
        "Voltage Metrology",
        "Voltage Reference",
        "Voltage Reference Drift",
        "Voltage Reference Aging",
        "Voltage Reference Validation",
        "Quartz Crystal Oscillator",
        "VCXO",
        "VC\/OCXO"
    ]
}