Numerical data for figures in the article, "Radio-Frequency Toroid Susceptometry of Magnetic Nanoparticles: What Goes Around Comes Around," by Ronald B. Goldfarb, National Institute of Standards and Technology.
About this Dataset
| Title | Radio-Frequency Toroid Susceptometry of Magnetic Nanoparticles |
|---|---|
| Description | Numerical data for figures in the article, "Radio-Frequency Toroid Susceptometry of Magnetic Nanoparticles: What Goes Around Comes Around," by Ronald B. Goldfarb, National Institute of Standards and Technology. |
| Modified | 2025-09-09 00:00:00 |
| Publisher Name | National Institute of Standards and Technology |
| Contact | mailto:[email protected] |
| Keywords | Colloids , dipole interactions , ferrofluids , impedance analyzers , magnetic relaxation , magnetic susceptibility , magnetic viscosity , nanoparticles , permeability , permeameters , radio frequency , standards , superparamagnetism , susceptometers , toroids. |
{
"identifier": "ark:\/88434\/mds2-3991",
"accessLevel": "public",
"contactPoint": {
"hasEmail": "mailto:[email protected]",
"fn": "Ron B. Goldfarb"
},
"programCode": [
"006:045"
],
"landingPage": "",
"title": "Radio-Frequency Toroid Susceptometry of Magnetic Nanoparticles",
"description": "Numerical data for figures in the article, \"Radio-Frequency Toroid Susceptometry of Magnetic Nanoparticles: What Goes Around Comes Around,\" by Ronald B. Goldfarb, National Institute of Standards and Technology.",
"language": [
"en"
],
"distribution": [
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3991\/Figure%202%2C%20Magnetization%20versus%20internal%20field%20scaled%20by%20temperature%20for%20PBG%20200%20frozen%20in%20zero%20field.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Magnetization versus internal field scaled by temperature for PBG 200 frozen in zero field.",
"mediaType": "text\/csv",
"title": "Figure 2"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3991\/Figure%203%2C%20Details%20of%20the%20magnetization%20curves%20widely%20spaced%20in%20temperature.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Details of the magnetization curves widely spaced in temperature.",
"mediaType": "text\/csv",
"title": "Figure 3"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3991\/Figure%204%2C%20Langevin%20fits%20to%20the%20265%20K%20magnetization%20curve.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Langevin fits to the 265 K magnetization curve.",
"mediaType": "text\/csv",
"title": "Figure 4"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3991\/Figure%205%2C%20For%20PBG%20200%2C%20field-cooled%2C%20zero-field-cooled%2C%20and%20thermoremanent%20magnetization%20as%20functions%20of%20temperature.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "For PBG 200, field-cooled, zero-field-cooled, and thermoremanent magnetization as functions of temperature.",
"mediaType": "text\/csv",
"title": "Figure 5"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2010%2C%20Real%2C%20imaginary%2C%20and%20modulus%20susceptibility%20for%20PBG%20900%20as%20functions%20of%20frequency%2C%20modified%20mean-field%20model.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Real, imaginary, and modulus susceptibility for PBG 900 as functions of frequency, modified mean-field model.",
"mediaType": "text\/csv",
"title": "Figure 10"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2011%2C%20Comparison%20of%20susceptibility%20moduli%20for%20PBG%20900.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Comparison of susceptibility moduli for PBG 900.",
"mediaType": "text\/csv",
"title": "Figure 11"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2012%2C%20Comparison%20of%20susceptibility%20moduli%20for%20PBG%20600.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Comparison of susceptibility moduli for PBG 600.",
"mediaType": "text\/csv",
"title": "Figure 12"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2014%2C%20Modulus%20of%20susceptibility%20at%20100%20MHz%20for%20all%20filling%20fractions.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Modulus of susceptibility at 100 MHz for all filling fractions.",
"mediaType": "text\/csv",
"title": "Figure 14"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2013%2C%20Comparison%20of%20susceptibility%20moduli%20for%20PBG%20200.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Comparison of susceptibility moduli for PBG 200.",
"mediaType": "text\/csv",
"title": "Figure 13"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2016%2C%20Modulus%20of%20susceptibility%20at%201%20GHz%20for%20all%20filling%20fractions.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Modulus of susceptibility at 1 GHz for all filling fractions.",
"mediaType": "text\/csv",
"title": "Figure 16"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2015%2C%20Modulus%20of%20susceptibility%20at%20500%20MHz%20for%20all%20filling%20fractions.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Modulus of susceptibility at 500 MHz for all filling fractions.",
"mediaType": "text\/csv",
"title": "Figure 15"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2017%2C%20Particle%20loss%20tangent%20for%20PBG%20900%20for%20the%20different%20models.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Particle loss tangent for PBG 900 for the different models.",
"mediaType": "text\/csv",
"title": "Figure 17"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2018%2C%20Imaginary%20part%20of%20susceptibility%20for%20PBG%20900%20for%20the%20different%20models.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Imaginary part of susceptibility for PBG 900 for the different models.",
"mediaType": "text\/csv",
"title": "Figure 18"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2019%2C%20Particle%20loss%20tangent%20for%20PBG%20600%20for%20the%20different%20models.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Particle loss tangent for PBG 600 for the different models.",
"mediaType": "text\/csv",
"title": "Figure 19"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2020%2C%20Imaginary%20part%20of%20susceptibility%20for%20PBG%20600%20for%20the%20different%20models.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Imaginary part of susceptibility for PBG 600 for the different models.",
"mediaType": "text\/csv",
"title": "Figure 20"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2021%2C%20Particle%20loss%20tangent%20for%20PBG%20200%20for%20the%20different%20models.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Particle loss tangent for PBG 200 for the different models.",
"mediaType": "text\/csv",
"title": "Figure 21"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%20A1%2C%20Distribution%20of%20particle%20diameters.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Distribution of particle diameters.",
"mediaType": "text\/csv",
"title": "Figure A1"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2023%2C%20Susceptibility%20moduli%20for%20evaporated%20PBG%20900%20with%20a%20filling%20fraction%20of%200.319.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Susceptibility moduli for evaporated PBG 900 with a filling fraction of 0.319.",
"mediaType": "text\/csv",
"title": "Figure 23"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%2022%2C%20Imaginary%20part%20of%20susceptibility%20for%20PBG%20200%20for%20the%20different%20models.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Imaginary part of susceptibility for PBG 200 for the different models.",
"mediaType": "text\/csv",
"title": "Figure 22"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3991\/Figure%206%2C%20Real%20and%20imaginary%20parts%20of%20relative%20permeability%20of%20PBG%20900%20as%20functions%20of%20frequency.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Real and imaginary parts of relative permeability of PBG 900 as functions of frequency.",
"mediaType": "text\/csv",
"title": "Figure 6"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3991\/Figure%207%2C%20Real%2C%20imaginary%2C%20and%20modulus%20susceptibility%20for%20PBG%20900%20as%20functions%20of%20frequency%2C%20Langevin%20model.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Real, imaginary, and modulus susceptibility for PBG 900 as functions of frequency, Langevin model.",
"mediaType": "text\/csv",
"title": "Figure 7"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3991\/Figure%208%2C%20Real%2C%20imaginary%2C%20and%20modulus%20susceptibility%20for%20PBG%20900%20as%20functions%20of%20frequency%2C%20Weiss%20model.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Real, imaginary, and modulus susceptibility for PBG 900 as functions of frequency, Weiss model.",
"mediaType": "text\/csv",
"title": "Figure 8"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%209%2C%20Real%2C%20imaginary%2C%20and%20modulus%20susceptibility%20for%20PBG%20900%20as%20functions%20of%20frequency%2C%20Onsager%20model.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Real, imaginary, and modulus susceptibility for PBG 900 as functions of frequency, Onsager model.",
"mediaType": "text\/csv",
"title": "Figure 9"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%20C2%2C%20Real%20part%20of%20relative%20permeability%20of%20a%20toroid%20of%20frozen%20deionized%20water.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Real part of relative permeability of a toroid of frozen deionized water.",
"mediaType": "text\/csv",
"title": "Figure C2"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-3991\/Figure%20C1%2C%20Real%20part%20of%20relative%20permeability%20of%20a%20toroid%20of%20deionized%20water.csv",
"format": "CSV UTF-8 Comma Delimited",
"description": "Real part of relative permeability of a toroid of deionized water.",
"mediaType": "text\/csv",
"title": "Figure C1"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-3991\/3991_README.txt",
"format": "TXT",
"description": "Description of data set.",
"mediaType": "text\/plain",
"title": "3991_README"
}
],
"bureauCode": [
"006:55"
],
"modified": "2025-09-09 00:00:00",
"publisher": {
"@type": "org:Organization",
"name": "National Institute of Standards and Technology"
},
"theme": [
"Nanotechnology:Nanomagnetics"
],
"keyword": [
"Colloids",
"dipole interactions",
"ferrofluids",
"impedance analyzers",
"magnetic relaxation",
"magnetic susceptibility",
"magnetic viscosity",
"nanoparticles",
"permeability",
"permeameters",
"radio frequency",
"standards",
"superparamagnetism",
"susceptometers",
"toroids."
]
}