U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

73 results found

SRM 2950a Respirable Alpha Quartz on Filter Media (Nominal Mass of Alpha Quartz: 5 µg to 500 µg)

Data provided by  National Institute of Standards and Technology

SRM 2950a Respirable Alpha Quartz on Filter Media (Nominal Mass of Alpha Quartz: 5 µg to 500 µg) - This Standard Reference Material (SRM) is intended primarily for the calibration of X-ray diffraction (XRD) spectrometers for the determination of respirable alpha quartz using National Institute for Occupational Safety and Health (NIOSH) Method 7500, or the equivalent. This data is public in the Certificate of Analysis for this material.

Tags: SRM 2950a,respirable,alpha quartz,filter,SRM,Standard Reference Material,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level)

Data provided by  National Institute of Standards and Technology

SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level) - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 2973,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

Air-broadening in near-infrared carbon dioxide line shapes: quantifying contributions from O2, N2, and Ar

Data provided by  National Institute of Standards and Technology

Dataset for generation of figures in Air-broadening in near-infrared carbon dioxide line shapes: quantifying contributions from O2, N2, and Ar (https://doi.org/10.1016/j.jqsrt.2021.107669)

Tags: spectroscopy,higher order lineshapes,carbon dioxide,

Modified: 2024-02-22

Views: 0

High accuracy spectroscopic parameters of the 1.27 um band of O2 measured with comb-referenced, cavity ring-down spectroscopy

Data provided by  National Institute of Standards and Technology

Data corresponding to Figs. 2,3,5,6,11,12,13,14 for Fleurbaey et al J. Quant Spectrosc. Radiat. Transf. vol 270, 107684 (2021). doi.org.10.1016/j.jqsrt.2021.107684

Tags: greenhouse gases,carbon dioxide,oceans,ph,marine mammals,remote sensing,seabirds,Environment and Climate,

Modified: 2024-02-22

Views: 0

Data from Laboratory Tests of a Prototype Carbon Dioxide Ground-Source Air Conditioner

Data provided by  National Institute of Standards and Technology

These data from the laboratory tests of a prototype residential liquid-to-air ground-source air conditioner (GSAC) using CO2 as the refrigerant. The data collection and processing methods are described in detail in this report:

Report Title: "Laboratory Tests of a Prototype Carbon Dioxide Ground-Source Air Conditioner", NIST Technical Note 2068
Publication Date: October 2019
DOI: https://doi.org/10.6028/NIST.TN.2068
Authors: Harrison Skye, Wei Wu

Tags: Air conditioner,carbon dioxide,CO2,ground-source heat pump,subcritical and transcritical cycles,

Modified: 2024-02-22

Views: 0

SRM 1450 Fibrous Glass Board: Retrospective Analysis

Data provided by  National Institute of Standards and Technology

Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis (eleven data sets in total).

Tags: bulk density,certified reference material,fit,guarded hot plate,high density molded fibrous glass board,model,regression analysis,Standard Reference Material,thermal conductivity,thermal insulation,

Modified: 2024-02-22

Views: 0

High Accuracy Near-infrared Carbon Dioxide Intensity Measurements to Support Remote Sensing

Data provided by  National Institute of Standards and Technology

Data files for the publication "High Accuracy Near-infrared Carbon Dioxide Intensity Measurements to Support Remote Sensing" in Geophysical Research Letters

Tags: greenhouse gases,carbon dioxide,remote sensing,

Modified: 2024-02-22

Views: 0

SRM 1450e Fibrous Glass Board

Data provided by  National Institute of Standards and Technology

SRM 1450e Fibrous Glass Board - This Standard Reference Material (SRM) is intended primarily for use in the measurement of the thermal conductivity or thermal resistance of insulation materials. SRM 1450e is a high-density fibrous glass board certified for bulk density and thermal conductivity. The SRM can be used in conjunction with ASTM C177 or ASTM C518. A unit of SRM 1450e consists of a square panel of fibrous glass and phenolic binder molded into a semi-rigid board.

Tags: bulk density,certified reference material,fit,guarded hot plate,high density molded fibrous glass board,model,regression analysis,Standard Reference Material,thermal conductivity,thermal insulation,

Modified: 2024-02-22

Views: 0

Calculated Diffusivities for Water Isotopologues in Carbon Dioxide, Nitrogen, and the Atmosphere of Mars, and for Methane Isotopologues in Nitrogen Representing the Atmosphere of Titan

Data provided by  National Institute of Standards and Technology

Values are computed for the dilute-gas diffusivity of water isotopologues in N2, CO2, and their mixture at a composition representing the atmosphere of Mars, for standard conditions of 101.325 kPa and water mole fraction approaching zero. Values are similarly computed for the diffusivity of methane isotopologues in N2, representing the atmosphere of Titan. Calculations employ state-of-the-art intermolecular potentials and classical trajectory calculations as described in the paper by R. Hellmann and A.H.

Tags: diffusivity,isotopes,Mars,Titan,water,methane,carbon dioxide,nitrogen,atmospheric science,

Modified: 2024-02-22

Views: 0

Ideal-gas Thermochemical Properties for Carbon Dioxide and its Isotopologues Calculated from Partition Functions

Data provided by  National Institute of Standards and Technology

Tabulations at 1 K intervals from 1 K to 6000 K of the partition function and standard-state isobaric heat capacity, entropy, and enthalpy for the 12 natural isotopologues of CO2, along with their standard uncertainties. Calculations performed with a partition function constructed from spectroscopic and theoretical data as described in the Appendix of the paper by A.H. Harvey, S.A. Tashkun, and E.W. Lemmon, to be submitted to J. Phys. Chem. Ref. Data. Note that the model does not account for dissociation of the CO2 molecule, making the results incomplete above approximately 3500 K.

Tags: carbon dioxide,heat capacity,enthalpy,entropy,ideal-gas properties,equation of state,partition function,thermochemistry,

Modified: 2024-02-22

Views: 0