SRM 3143 Rhenium (Re) Standard Solution Lot No. 140825
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of rhenium. A unit of SRM 3143 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of rhenium. The solution contains nitric acid at a volume fraction of approximately 10 %, equivalent to an amount of substance concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: rhenium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3147a Samarium (Sm) Standard Solution Lot No. 140115
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of samarium. A unit of SRM 3147a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of samarium. The solution contains nitric acid at a volume fraction of approximately 10 %, which is equivalent to a concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: samarium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3150 Silicon (Si) Standard Solution, Lot No. 130912
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of silicon. A unit of SRM 3150 consists of 50 mL of solution prepared gravimetrically to contain a known mass fraction of silicon in a high-density polyethylene bottle sealed in an aluminized bag. The solution is prepared gravimetrically from sodium metasilicate nonahydrate to contain a known mass fraction of silicon in water. This data is public in the Certificate of Analysis for this material.
Tags: silicon,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3151 Silver (Ag) Standard Solution Lot No. 160729
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of silver. A unit of SRM 3151 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of silver. The solution contains nitric acid at a mass fraction of approximately 14 %. This data is public in the Certificate of Analysis for this material.
Tags: silver,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3156 Tellurium (Te) Standard Solution Lot No. 140830
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of tellurium. A unit of SRM 3156 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of tellurium. The solution contains hydrochloric acid at a volume fraction of approximately 10 %, which is equivalent to an amount of substance concentration (molarity) of approximately 1.2 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: tellurium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3158 Thallium (Tl) Standard Solution Lot No. 993012
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of thallium. A unit of SRM 3158 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of thallium. The solution contains nitric acid at a volume fraction of approximately 10 %. This data is public in the Certificate of Analysis for this material.
Tags: thallium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3163 Tungsten (W) Standard Solution, Lot No. 140606
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of tungsten. A unit of SRM 3163 consists of 50 mL of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of tungsten in a high-density polyethylene bottle sealed in an aluminized bag.
Tags: tungsten,pure materials,cations,single-element solutions,spectrometry,Biosciences and Health,
Modified: 2024-02-22
Views: 0
SRM 3165 Vanadium (V) Standard Solution Lot No. 992706
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of vanadium. A unit of SRM 3165 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of vanadium. The solution contains nitric acid at an amount of substance concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: vanadium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3166a Ytterbium (Yb) Standard Solution Lot No 140114
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of ytterbium. A unit of SRM 3166a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of ytterbium. The solution contains nitric acid at a volume fraction of approximately 10 %, equivalent to an amount of substance concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: ytterbium,pure materials,cations,single-element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
Thermographic measurements of single and multiple scan tracks on nickel alloy 625 substrates with and without a powder layer in a commercial laser powder bed fusion process (an additive manufacturing technology)
Data provided by National Institute of Standards and Technology
This dataset contains thermographic measurements acquired during single and multiple track scans on bare substrates and on single layers of powder. The substrates and powder are nickel alloy 625 and the experiments are performed inside a commercial laser powder bed fusion machine. There are four experiment cases: 1) a single scan track on a bare substrate, 2) a single scan track on a single hand-spread layer of powder, 3) multiple (39) scan tracks covering an area on a bare substrate, and 4) multiple (39) scan tracks solidifying a single hand-spread layer of powder.
Tags: additive manufacturing,powder bed fusion,laser,thermography,temperature measurement,melt pool,melt pool length,cooling rate,Inconel 625,IN 625,nickel alloy 625,model validation,
Modified: 2024-02-22