SRM 1450 Fibrous Glass Board: Retrospective Analysis

Data provided by  National Institute of Standards and Technology

Thermal conductivity data acquired previously for the establishment of Standard Reference Material (SRM) 1450, Fibrous Glass Board, as well as subsequent renewals 1450a, 1450b, 1450c, and 1450d, are re-analyzed collectively and as individual data sets. Additional data sets for proto-1450 material lots are also included in the analysis (eleven data sets in total).

Tags: bulk density,certified reference material,fit,guarded hot plate,high density molded fibrous glass board,model,regression analysis,Standard Reference Material,thermal conductivity,thermal insulation,

Modified: 2024-02-22

Views: 0

SRM 1450e Fibrous Glass Board

Data provided by  National Institute of Standards and Technology

SRM 1450e Fibrous Glass Board - This Standard Reference Material (SRM) is intended primarily for use in the measurement of the thermal conductivity or thermal resistance of insulation materials. SRM 1450e is a high-density fibrous glass board certified for bulk density and thermal conductivity. The SRM can be used in conjunction with ASTM C177 or ASTM C518. A unit of SRM 1450e consists of a square panel of fibrous glass and phenolic binder molded into a semi-rigid board.

Tags: bulk density,certified reference material,fit,guarded hot plate,high density molded fibrous glass board,model,regression analysis,Standard Reference Material,thermal conductivity,thermal insulation,

Modified: 2024-02-22

Views: 0

Optical Modeling of Single Asian Dust and Marine Air Particles: A Comparison with Geometric Particle Shapes for Remote Sensing

Data provided by  National Institute of Standards and Technology

The project that produced these data involved the analysis and modeling of atmospheric Asian dust particles and background marine air particles collected in Hawaii, USA at the Mauna Loa Observatory (MLO) of the National Oceanic and Atmospheric Administration. Individual heterogeneous dust particles were analyzed with focused ion-beam scanning electron microscopy and energy-dispersive X-ray spectroscopy.

Tags: atmospheric aerosol,Asian dust,light scattering,light absorption,radiative forcing,climate change,focused ion-beam scanning electron microscopy,FIB-SEM,energy-dispersive X-ray spectroscopy,EDX,focused ion-beam tomography,optical property modeling,discrete dipole approximation method,Environment and Climate,

Modified: 2024-02-22

Views: 0

Aggregation of Purified Protein Reference Materials Characterized by Asymmetric Flow Field Flow Fractionation

Data provided by  National Institute of Standards and Technology

This is a file containing aggregation data for two proteins that were thermomechanically aggregated. The aggregated proteins were separated by asymmetric flow field flow fractionation and separated protein fractions were detected and quantified by UV spectrophotometry and multi-angle light scattering. The UV spectrophotometry was used to quantify the amount of residual monomer, which is reported herein. The multi-angle light scattering was fitted to a relevant model to calculate the molecular weight of the aggregated protein, also reported herein.

Tags: electrical sensing zone,flow imaging,light obscuration,particle,protein aggregate,protein particle,subvisible particle,visible particle,Biosciences and Health,

Modified: 2024-02-22

Views: 0

Comparison of primary laser spectroscopy and mass spectrometry methods for measuring mass concentration of gaseous elemental mercury

Data provided by  National Institute of Standards and Technology

Data for mass concentration analysis and spectral analysis for the paper titled, "Comparison of primary laser spectroscopy and mass spectrometry methods for measuring mass concentration of gaseous elemental mercury"

Tags: mercury,laser absorption spectroscopy,Standard Generator,SI traceability,ID-CV-ICP-MS,primary measurement method,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 3163 Tungsten (W) Standard Solution, Lot No. 140606

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of tungsten. A unit of SRM 3163 consists of 50 mL of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of tungsten in a high-density polyethylene bottle sealed in an aluminized bag.

Tags: tungsten,pure materials,cations,single-element solutions,spectrometry,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 3180 Iodide Anion (I-) Standard Solution

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of iodide. A unit of SRM 3180 consists of five 5 mL, sealed, amber, borosilicate glass ampoules of solution prepared gravimetrically to contain a known mass fraction of iodide. The matrix of the solution is water containing sodium sulfite at a concentration of approximately 0.01 mol/L and sodium hydroxide at a concentration of approximately 0.005 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,iodide,anion,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3181 Sulfate Anion (SO42-) Standard Solution

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of sulfate using anion ion chromatography (IC) or other methods. A unit of SRM 3181 consists of five 10 mL sealed borosilicate glass ampoules of solution prepared gravimetrically to contain a known mass fraction of sulfate dissolved in filtered (0.22 ?m) water having a minimum resistivity of 18 megaohm centimeters. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,sulfate,anion,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3182 Chloride Anion (Cl-) Standard Solution

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended as a primary standard for the quantitative determination of chloride using anion ion chromatography (IC) or other methods. A unit of SRM 3182 consists of five 10 mL sealed borosilicate glass ampoules of solution. The solution is prepared gravimetrically to contain a known mass fraction of chloride dissolved in filtered (0.22 µm) water having a minimum resistivity of 18 megaohm centimeters. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,chloride,anion,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3183 Fluoride Anion (F-) Standard Solution

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended as a primary calibration standard for the quantitative determination of fluoride using anion ion chromatography (IC) or other methods. A unit of SRM 3183 consists of 50 mL of solution in a high density polyethylene bottle sealed in an aluminized bag. The solution is prepared gravimetrically to contain a known mass fraction of fluoride dissolved in filtered (0.22 µm) water having a minimum resistivity of 18 megaohm centimeters. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,fluoride,anion,Advanced Materials,

Modified: 2024-02-22

Views: 0