U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

40 results found

Construction of a Dual-enzyme, Subzero (-30 degree C) Chromatography System and Multi-channel Precision Temperature Controller for Hydrogen-Deuterium Exchange Mass Spectrometry

Data provided by  National Institute of Standards and Technology

This tutorial provides mechanical drawings, electrical schematics, parts lists, STL files for 3D-printed parts, IGS files, and instructions for automated machining necessary for construction of a dual-protease, subzero, liquid chromatography system for hydrogen-deuterium exchange mass spectrometry. Electrical schematics for construction of a multi-zone temperature controller that regulate to ±0.1 oC are also included in this tutorial.

Tags: liquid chromatography,hydrogen-deuterium exchange,mass spectrometry,precision,peptide,protein,proteolysis,proteomics,reference material,temperature control.,

Modified: 2024-02-22

Views: 0

Comparison of primary laser spectroscopy and mass spectrometry methods for measuring mass concentration of gaseous elemental mercury

Data provided by  National Institute of Standards and Technology

Data for mass concentration analysis and spectral analysis for the paper titled, "Comparison of primary laser spectroscopy and mass spectrometry methods for measuring mass concentration of gaseous elemental mercury"

Tags: mercury,laser absorption spectroscopy,Standard Generator,SI traceability,ID-CV-ICP-MS,primary measurement method,Environment and Climate,

Modified: 2024-02-22

Views: 0

Development of a Tool to Determine the Variability of Consensus Mass Spectra Supporting Data

Data provided by  National Institute of Standards and Technology

Supporting datasets and algorithms (R-based) for the manuscript entitled "Development of a Tool to Determine the Variability of Consensus Mass Spectra", including an R Markdown script to reproduce the manuscript's figures.

Tags: mass spectrometry,uncertainty analysis,per- and polyfluoroalkyl substances,PFAS,reference mass spectrum,

Modified: 2024-02-22

Views: 0

SRM 3133 Mercury (Hg) Standard Solution Lot No. 160921

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of mercury. A unit of SRM 3133 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of mercury. The solution contains nitric acid at an approximate mass fraction of 10 %. This data is public in the Certificate of Analysis for this material.

Tags: mercury,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Centroid Data measured between 3.6 degrees C and 25.4 degrees C for the Fab Fragment of NISTmAb

Data provided by  National Institute of Standards and Technology

The spreadsheet file reported herein provides centroid data, descriptive of deuterium uptake, for the Fab Fragment of NISTmAb (PDB: 5K8A) reference material, as measured by the bottom-up hydrogen-deuterium exchange mass spectrometry (HDX-MS) method. The protein sample was incubated in deuterium-rich solutions under uniform pH and salt concentrations between 3.6 degrees C and 25.4 degrees C for seven intervals ranging (0 to 14,400) s plus a control sample that simulates a Fab Fragment immersed for infinite time in D2O.

Tags: hydrogen-deuterium exchange,hydrogen exchange,HDX-MS,interlaboratory comparison,mass spectrometry,peptide,precision,proteomics,reference material,repeatability,reproducibility,

Modified: 2024-02-22

Views: 0

Albatross Species Chemical Database and Annotated Bibliography

Data provided by  National Institute of Standards and Technology

Database and annotated bibliography of contaminants in tissues from albatross (Family Diomedeidae) species. Database is saved as current Microsoft Access 365 .accdb file and a backward compatible to Access 2000 .mdb file and a Microsoft Excel .xlsx file which has the database output information, introduction with description of headers, and some derived data. A free viewer for Excel is at: https://www.microsoft.com/en-us/p/xlsx-viewer-free/9nblggh6hbf4?activet….

Tags: seabird,tissues,PAHs,PBDEs,PCBs,PCDDs,PCDF,perflourinated acids,phenols,toxicology pesticides,mercury,trace elements,heavy metals,organic,inorganic,chemistry,stable isotopes,Environment and Climate,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the Fc(gamma)RIa (CD64) Receptor

Data provided by  National Institute of Standards and Technology

This database gives hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, Fc(gamma)RIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.

Tags: antibody-receptor interaction,chromatography,HDX-MS,hydrogen-deuterium exchange,glycosylation,mass spectrometry,monoclonal antibody,precision,peptide,protein,proteolysis,proteomics,receptor.,

Modified: 2024-02-22

Views: 0

NIST Atomic Spectra Database - SRD 78

Data provided by  National Institute of Standards and Technology

This database provides access and search capability for NIST critically evaluated data on atomic energy levels, wavelengths, and transition probabilities that are reasonably up-to-date. The Atomic Spectroscopy Data Center has carried out these critical compilations. The Data Center is located in the Physical Measurement Laboratory at the National Institute of Standards and Technology (NIST).

Tags: cesium,chlorine,chromium,cobalt,columbium,copernicium,copper,curium,darmstadtium,database,deuterium,doubly-charged,dubnium,dysprosium,einsteinium,element,energy levels,erbium,europium,fermium,flerovium,fluorine,francium,gadolinium,gallium,germanium,gold,ground states,hafnium,hassium,helium,holmium,hydrogen,indium,iodine,ionization potentials,ionization-energies,ionization-limits,ionized-atoms,iridium,iron,mendelevium,mercury,molybdenum,multiply-charged,neodymium,neon,neptunium,neutral,nickel,niobium,nitrogen,nobelium,osmium,oxygen,palladium,phosphorus,platinum,plutonium,polonium,potassium,praseodymium,promethium,protactinium,quadruply-charged,radium,rhenium,rhodium,roentgenium,rubidium,ruthenium,rutherfordium,samarium,scandium,seaborgium,selenium,silicium,silicon,silver,singly-charged,sodium,spectra,spectral lines,spectroscopy,spectrum,strontium,sulfur,sulphur,tantalum,technetium,tellurium,terbium,thallium,thorium,thulium,tin,titanium,transition probabilities,triply-charged,tritium,tungsten,ununbium,ununhexium,ununoctium,ununpentium,ununquadium,ununseptium,ununtrium,unununium,uranium,vanadium,wavelengths,xenon,ytterbium,yttrium,zinc,zirconium,krypton,kurchatovium,lawrencium,lanthanum,lead,lithium,livermorium,lutetium,magnesium,manganese,meitnerium,Atomic,Atomic Spectroscopy,Radon,actinium,aluminium,aluminum,americium,antimony,argon,arsenic,astatine,atom,atomic physics,atomic property,atomic-ions,barium,berkelium,beryllium,bismuth,bohrium,boron,bromine,cadmium,calcium,californium,carbon,cerium,

Modified: 2024-02-22

Views: 0

NIST/EPA Gas-Phase Infrared Database JCAMP Format - SRD 35

Data provided by  National Institute of Standards and Technology

This data collection contains 5,228 infrared spectra of different compounds along with chemical structures for most of them. Spectra are provided on a CD-ROM in the JCAMP-DX (Joint Committee for Atomic and Molecular Physical Data 'Data Exchange') format. Chemical structures are provided in the MOL-file format. The IR data originated from two sources, from the so-called 'EPA Vapor-Phase IR Library' and from NIST laboratories.

Tags: Joint Committee for Atomic and Molecular Physical Data,absorption spectra,chemical structures,gas phases,gases,infra red,infrared spectra,mass spectra,mass spectrometry,molecular spectroscopy,molecular vibrations,physics,spectra,spectroscopy,structural data,structures,vapor phase infrared,

Modified: 2024-02-22

Views: 0