Raw data files that were used in writing "Analysis of human plasma metabolites across different liquid chromatography/mass spectrometry platforms: Cross-platform transferable chemical signatures" by Kelly H. Telu, Xinjian Yan, William E. Wallace, Stephen E. Stein and Yamil Simón-Manso, Published paper: DOI: 10.1002/rcm.7475

Data provided by  National Institute of Standards and Technology

Liquid-chromatography-mass spectrometry (LC-MS) raw data sets from various instruments delivered in their native instrument format. 31 files in all. 7.5 GB data.

Tags: human blood plasma,metabolomics,mass spectrometry,liquid chromatography,SRM 1950,

Modified: 2024-02-22

Views: 0

SRM 968f Fat-Soluble Vitamins in Human Serum

Data provided by  National Institute of Standards and Technology

Standard Reference Material (SRM) 968 and its reissues are human serum based materials used as validation standards by clinical, epidemiological, and nutrition laboratories. Historically, about 300 units of this SRM have been sold annually. Based on this annual sales projection, as of November 1, 2015 there were about 16 months of inventory of the current issue: SRM 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum.

Tags: fat-soluble vitamins,clinical,Frozen Human Serum,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 3669 Arsenic Species in Frozen Human Urine (Elevated Levels)

Data provided by  National Institute of Standards and Technology

SRM 3669 Arsenic Species in Frozen Human Urine (Elevated Levels) - This Standard Reference Material (SRM) is intended primarily for validating analytical methods and measurements for the determination of arsenic species in human urine. A unit of SRM 3669 consists of five pouches each containing a vial of arsenic species in frozen human urine at elevated levels. Each vial contains nominally 1.5 mL of urine. This data is public in the Certificate of Analysis for this material.

Tags: SRM 3669,arsenic,arsenic species,urine,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 2950a Respirable Alpha Quartz on Filter Media (Nominal Mass of Alpha Quartz: 5 µg to 500 µg)

Data provided by  National Institute of Standards and Technology

SRM 2950a Respirable Alpha Quartz on Filter Media (Nominal Mass of Alpha Quartz: 5 µg to 500 µg) - This Standard Reference Material (SRM) is intended primarily for the calibration of X-ray diffraction (XRD) spectrometers for the determination of respirable alpha quartz using National Institute for Occupational Safety and Health (NIOSH) Method 7500, or the equivalent. This data is public in the Certificate of Analysis for this material.

Tags: SRM 2950a,respirable,alpha quartz,filter,SRM,Standard Reference Material,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 3104a Barium (Ba) Standard Solution Lot No. 140909

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of barium. A unit of SRM 3104a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of barium. The solution contains nitric acid at a volume fraction of approximately 1 %, which is equivalent to a concentration (molarity) of approximately 0.16 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: barium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3110 Cerium (Ce) Standard Solution Lot No. 160830

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of cerium. A unit of SRM 3110 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of cerium. The solution contains nitric acid at a mass fraction of approximately 16 %. This data is public in the Certificate of Analysis for this material.

Tags: cerium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3120a Germanium (Ge) Standard Solution Lot No. 080429

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of germanium. A unit of SRM 3120a consists of 50 mL of a single element solution in a high density polyethylene bottle sealed in an aluminized bag. The solution was prepared gravimetrically to contain a known mass fraction of germanium. The solution contains nitric acid at a concentration of approximately 1.6 mol/L and hydrofluoric acid at a concentration of approximately 0.6 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: germanium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3122 Hafnium (Hf) Standard Solution Lot No. 151120

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of hafnium. A unit of SRM 3122 consists of 50 mL of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of hafnium in a high density polyethylene bottle sealed in an aluminized bag. The solution contains approximately 8 % nitric acid (volume fraction) and approximately 1 % hydrofluoric acid (volume fraction), equivalent to amount of substance concentrations (molarities) of 1.3 mol/L and 0.3 mol/L, respectively.

Tags: hafnium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3127a Lanthanum (La) Standard Solution Lot No. 151030

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of lanthanum. A unit of SRM 3127a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of lanthanum. The solution contains nitric acid at a volume fraction of approximately 10 %, equivalent to an amount of substance concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: lanthanum,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3131a Magnesium (Mg) Standard Solution Lot 140110

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of magnesium. A unit of SRM 3131a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of magnesium. The solution contains nitric acid at a volume fraction of approximately 10 %, equivalent to an amount of substance concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: magnesium,pure materials,cations,single-element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0