SRM 3156 Tellurium (Te) Standard Solution Lot No. 140830

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of tellurium. A unit of SRM 3156 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of tellurium. The solution contains hydrochloric acid at a volume fraction of approximately 10 %, which is equivalent to an amount of substance concentration (molarity) of approximately 1.2 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: tellurium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3158 Thallium (Tl) Standard Solution Lot No. 993012

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of thallium. A unit of SRM 3158 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of thallium. The solution contains nitric acid at a volume fraction of approximately 10 %. This data is public in the Certificate of Analysis for this material.

Tags: thallium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3165 Vanadium (V) Standard Solution Lot No. 992706

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of vanadium. A unit of SRM 3165 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of vanadium. The solution contains nitric acid at an amount of substance concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: vanadium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

JARVIS: Joint Automated Repository for Various Integrated Simulations

Data provided by  National Institute of Standards and Technology

JARVIS (Joint Automated Repository for Various Integrated Simulations) is a repository designed to automate materials discovery using classical force-field, density functional theory, machine learning calculations and experiments.

The Force-field section of JARVIS (JARVIS-FF) consists of thousands of automated LAMMPS based force-field calculations on DFT geometries. Some of the properties included in JARVIS-FF are energetics, elastic constants, surface energies, defect formations energies and phonon frequencies of materials.

Tags: Density functional theory,classical interatomic potential,force-field,python,JARVIS,MGI,MDCS,RESTAPI,automation,

Modified: 2024-02-22

Views: 0

FEASST: Free Energy and Advanced Sampling Simulation Toolkit

Data provided by  National Institute of Standards and Technology

The Free Energy and Advanced Sampling Simulation Toolkit (FEASST) is a free, open-source, modular program to conduct molecular and particle-based simulations with flat-histogram Monte Carlo and molecular dynamics methods. It is a software written in C++ and python which is made publicly available to aid in reproducibility. It is also provided as a service to the scientific community in which there are few , if any, Monte Carlo programs that support flat histogram methods and advanced sampling algorithms. This software is expected to be updated frequently with new methods.

Tags: monte carlo,molecular simulation,free energy,flat histogram,C++,python,

Modified: 2024-02-22

Views: 0

Source of the Refl1d program for modeling and analyzing neutron and X-ray reflectometry data, with the addition of distributed roughness capability.

Data provided by  National Institute of Standards and Technology

Source of the Refl1d program for modeling and analyzing neutron and X-ray reflectometry data, with the addition of distributed roughness capability.

Tags: neutron scattering,reflectometry,polarized,Bayesian,roughness,python,

Modified: 2024-02-22

Views: 0

pyPRISM: A Computational Tool for Liquid State Theory Calculations of Macromolecular Materials

Data provided by  National Institute of Standards and Technology

Polymer Reference Interaction Site Model (PRISM) theory describes the equilibrium spatial-correlations of liquid-like polymer systems including melts, blends, solutions, block copolymers, ionomers, liquid crystal forming polymers and nanocomposites. Using PRISM theory, one can calculate thermodynamic (e.g., second virial coefficients, Flory-Huggins interaction parameters, potentials of mean force) and structural (eg., pair correlation functions, structure factors) information for these macromolecular materials.

Tags: polymer,theory,liquid-state theory,python,polymer nanocomposite,polymer solution,X-ray scattering,neutron scattering,software,tool,computation,

Modified: 2024-02-22

Views: 0

pyLLE: a Fast and User Friendly Lugiato-Lefever Equation Solver

Data provided by  National Institute of Standards and Technology

We present the development of pyLLE, a freely accessible Lugiato-Lefever equation solver programmed in Python and Julia and optimized for the simulation of microresonator frequency combs. Examples illustrating its operation and performance are presented.

Tags: photonics,optics,frequency combs,python,julia,

Modified: 2024-02-22

Views: 0

FIZ/NIST Inorganic Crystal Structure Database (ICSD) - SRD 84

Data provided by  National Institute of Standards and Technology

The Inorganic Crystal Structure Database (ICSD) is produced cooperatively by the Fachinformationszentrum Karlsruhe (FIZ) and the National Institute of Standards and Technology (NIST). Components and devices used in a broad spectrum of technology sectors such as health care, communications, energy and electronics are manufactured from crystalline materials; the development of advanced crystalline materials requires accurate crystal-structure data.

Tags: Rietveld profiles,X ray crystallography,X ray diffraction,X rays,XRD,absolute configurations,chemical structures,crystal data,crystal structures,crystallography,crystals,defect structures,diffraction,disorders,electron diffractions,electrons,identification,inorganic,inorganic structures,magnetic structures,materials,metals,mineral names,minerals,mixed crystal solid solutions,mixed crystals,modulated structures,neutron diffractions,neutrons,nuclear magnetic resonance,polytype structures,powder simulations,power,powers,prediction,simulations,single crystals,structure predictions,structures,synchroton radiations,twinned crystals,visualizations,x ray diffractions,

Modified: 2024-02-22

Views: 0

SRM 3102a Antimony (Sb) Standard Solution Lot No. 140911

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of antimony. A unit of SRM 3102a consists of 50 mL of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of antimony in a high-density polyethylene bottle sealed in an aluminized bag.

Tags: antimony,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0