SRM 2691 Coal Fly Ash
Data provided by National Institute of Standards and Technology
Standard Reference Material 2691 Coal Fly Ash - This Standard Reference Material (SRM) is intended for use in the evaluation of analytical methods used for the classification of coal fly ash and for the determination of constituent elements in coal fly ash or materials of a similar matrix. A unit of SRM 2691 consists of three 10 g hermetically sealed glass vials of fly ash pulverized to less than 150 ?m particle size and blended to a high degree of homogeneity. This data is public in the Certificate of Analysis for this material.
Tags: SRM,Standard Reference Material,coal,coal fly ash,sulfur,Energy,
Modified: 2024-02-22
Views: 0
SRM 2692c Bituminous Coal (Nominal Mass Fraction 1 % Sulfur)
Data provided by National Institute of Standards and Technology
SRM 2692c Bituminous Coal (Nominal Mass Fraction 1 % Sulfur) - This Standard Reference Material (SRM) is intended primarily for use in the evaluation of techniques employed in the determination of sulfur, mercury, chlorine, and ash content in coal and materials of a similar matrix. A unit of SRM 2692c consists of 50 g of bituminous coal ground to pass a 250 µm (60 mesh) sieve, homogenized, and packaged in an amber glass bottle. This data is public in the Certificate of Analysis for this material.
Tags: SRM,Standard Reference Material,coal,sulfur,mercury,chlorine,Energy,
Modified: 2024-02-22
Views: 0
SRM 2693 Bituminous Coal (Nominal Mass Fraction 0.5 % Sulfur)
Data provided by National Institute of Standards and Technology
Standard Reference Material 2693 Bituminous Coal (Nominal Mass Fraction 0.5 % Sulfur) - This Standard Reference Material (SRM) is intended primarily for use in the evaluation of techniques employed in the determination of sulfur, mercury, chlorine, and ash content in coal and materials of a similar matrix. A unit of SRM 2693 consists of 50 g of bituminous coal ground to pass a 250 µm (60 mesh) sieve, homogenized, and packaged in an amber glass bottle and then sealed in an aluminized bag. This data is public in the Certificate of Analysis for this material.
Tags: SRM,Standard Reference Material,coal,sulfur,mercury,chlorine,Energy,
Modified: 2024-02-22
Views: 0
SRM 3156 Tellurium (Te) Standard Solution Lot No. 140830
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of tellurium. A unit of SRM 3156 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of tellurium. The solution contains hydrochloric acid at a volume fraction of approximately 10 %, which is equivalent to an amount of substance concentration (molarity) of approximately 1.2 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: tellurium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3104a Barium (Ba) Standard Solution Lot No. 140909
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of barium. A unit of SRM 3104a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of barium. The solution contains nitric acid at a volume fraction of approximately 1 %, which is equivalent to a concentration (molarity) of approximately 0.16 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: barium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3110 Cerium (Ce) Standard Solution Lot No. 160830
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of cerium. A unit of SRM 3110 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of cerium. The solution contains nitric acid at a mass fraction of approximately 16 %. This data is public in the Certificate of Analysis for this material.
Tags: cerium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3120a Germanium (Ge) Standard Solution Lot No. 080429
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of germanium. A unit of SRM 3120a consists of 50 mL of a single element solution in a high density polyethylene bottle sealed in an aluminized bag. The solution was prepared gravimetrically to contain a known mass fraction of germanium. The solution contains nitric acid at a concentration of approximately 1.6 mol/L and hydrofluoric acid at a concentration of approximately 0.6 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: germanium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3122 Hafnium (Hf) Standard Solution Lot No. 151120
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of hafnium. A unit of SRM 3122 consists of 50 mL of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of hafnium in a high density polyethylene bottle sealed in an aluminized bag. The solution contains approximately 8 % nitric acid (volume fraction) and approximately 1 % hydrofluoric acid (volume fraction), equivalent to amount of substance concentrations (molarities) of 1.3 mol/L and 0.3 mol/L, respectively.
Tags: hafnium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3127a Lanthanum (La) Standard Solution Lot No. 151030
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of lanthanum. A unit of SRM 3127a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of lanthanum. The solution contains nitric acid at a volume fraction of approximately 10 %, equivalent to an amount of substance concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: lanthanum,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3133 Mercury (Hg) Standard Solution Lot No. 160921
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of mercury. A unit of SRM 3133 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of mercury. The solution contains nitric acid at an approximate mass fraction of 10 %. This data is public in the Certificate of Analysis for this material.
Tags: mercury,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22