This data set provides heat detector temperatures in a single-story ranch structure with a living room, kitchen, dining room, and three bedrooms. 20000 sets of detector temperatures are generated using CData [1]. The data set are obtained based on simulation runs with various fire conditions and door opening conditions. The fire is described based on t-squared law. The peak heat release rate and time to peak range from approximately 1667 kW to 4620 kW and from 210 s to 1540 s, respectively. A detailed description of this work can be found in Ref. [2].[1] Reneke, P.A., Peacock, R.D., Gilbert, S.W. and Cleary, T.G., 2021. CFAST Consolidated Fire and Smoke Transport (Version 7) Volume 5: CFAST Fire Data Generator (CData). NIST Technical Note 1889v5. Gaithersburg, MD.[2] Fu, E.Y., Tam, W.C., Wang, J., Peacock, R., Reneke, P., Ngai, G., Leong, H.V. and Cleary, T., 2021, May. Predicting Flashover Occurrence using Surrogate Temperature Data. In Proceedings of the AAAI Conference on Artificial Intelligence (Vol. 35, No. 17, pp. 14785-14794).
About this Dataset
| Title | Synthetic Temperature Data for Predicting Flashover Occurrence Using Surrogate Temperature Data |
|---|---|
| Description | This data set provides heat detector temperatures in a single-story ranch structure with a living room, kitchen, dining room, and three bedrooms. 20000 sets of detector temperatures are generated using CData [1]. The data set are obtained based on simulation runs with various fire conditions and door opening conditions. The fire is described based on t-squared law. The peak heat release rate and time to peak range from approximately 1667 kW to 4620 kW and from 210 s to 1540 s, respectively. A detailed description of this work can be found in Ref. [2].[1] Reneke, P.A., Peacock, R.D., Gilbert, S.W. and Cleary, T.G., 2021. CFAST Consolidated Fire and Smoke Transport (Version 7) Volume 5: CFAST Fire Data Generator (CData). NIST Technical Note 1889v5. Gaithersburg, MD.[2] Fu, E.Y., Tam, W.C., Wang, J., Peacock, R., Reneke, P., Ngai, G., Leong, H.V. and Cleary, T., 2021, May. Predicting Flashover Occurrence using Surrogate Temperature Data. In Proceedings of the AAAI Conference on Artificial Intelligence (Vol. 35, No. 17, pp. 14785-14794). |
| Modified | 2021-01-09 00:00:00 |
| Publisher Name | National Institute of Standards and Technology |
| Contact | mailto:[email protected] |
| Keywords | Flashover Prediction; Recurrent Neural Network; Validation with Experimental Data; Smart Fire Fighting |
{
"identifier": "ark:\/88434\/mds2-2479",
"accessLevel": "public",
"contactPoint": {
"hasEmail": "mailto:[email protected]",
"fn": "Wai Cheong Tam"
},
"programCode": [
"006:045"
],
"landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-2479",
"title": "Synthetic Temperature Data for Predicting Flashover Occurrence Using Surrogate Temperature Data",
"description": "This data set provides heat detector temperatures in a single-story ranch structure with a living room, kitchen, dining room, and three bedrooms. 20000 sets of detector temperatures are generated using CData [1]. The data set are obtained based on simulation runs with various fire conditions and door opening conditions. The fire is described based on t-squared law. The peak heat release rate and time to peak range from approximately 1667 kW to 4620 kW and from 210 s to 1540 s, respectively. A detailed description of this work can be found in Ref. [2].[1] Reneke, P.A., Peacock, R.D., Gilbert, S.W. and Cleary, T.G., 2021. CFAST Consolidated Fire and Smoke Transport (Version 7) Volume 5: CFAST Fire Data Generator (CData). NIST Technical Note 1889v5. Gaithersburg, MD.[2] Fu, E.Y., Tam, W.C., Wang, J., Peacock, R., Reneke, P., Ngai, G., Leong, H.V. and Cleary, T., 2021, May. Predicting Flashover Occurrence using Surrogate Temperature Data. In Proceedings of the AAAI Conference on Artificial Intelligence (Vol. 35, No. 17, pp. 14785-14794).",
"language": [
"en"
],
"distribution": [
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData8001-10000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData8001-10000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData8001-10000.xlsx",
"description": "Data for Experiment 8001-10000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData8001-10000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData10001-12000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData10001-12000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData10001-12000.xlsx",
"description": "Data for Experiment 10001-12000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData10001-12000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData12001-14000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData12001-14000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData12001-14000.xlsx",
"description": "Data for Experiment 12001-14000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData12001-14000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData14001-16000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData14001-16000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData14001-16000.xlsx",
"description": "Data for Experiment 14001-16000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData14001-16000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData16001-18000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData16001-18000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData16001-18000.xlsx",
"description": "Data for Experiment 16001-18000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData16001-18000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData18001-20000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData18001-20000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData18001-20000.xlsx",
"description": "Data for Experiment 18001-20000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData18001-20000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData1-2000.xlsx",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/P-Flash_RangeHouse_SixCompartments_AllData_2021-1-9.xlsx",
"description": "Data Description",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "P-Flash_RangeHouse_SixCompartments Summary"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData1-2000.xlsx",
"description": "RangeHouseData1-2000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData1-2000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData2001-4000.xlsx",
"description": "RangeHouseData2001-4000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData2001-4000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData1-2000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData1-2000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData1-2000.xlsx",
"description": "Data for Experiment 1 to 2000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData1-2000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData2001-4000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData2001-4000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData2001-4000.xlsx",
"description": "Data for Experiments 2001-4000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData2001-4000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData4001-6000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData4001-6000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData4001-6000.xlsx",
"description": "Data for Experiment 4001-6000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData4001-6000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData6001-8000.xlsx.sha256",
"mediaType": "text\/plain",
"title": "SHA256 File for RangeHouseData6001-8000"
},
{
"downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2479\/RangeHouseData6001-8000.xlsx",
"description": "Data for Experiment 6001-8000",
"mediaType": "application\/vnd.openxmlformats-officedocument.spreadsheetml.sheet",
"title": "RangeHouseData6001-8000"
}
],
"bureauCode": [
"006:55"
],
"modified": "2021-01-09 00:00:00",
"publisher": {
"@type": "org:Organization",
"name": "National Institute of Standards and Technology"
},
"theme": [
"Fire:Fire detection",
"Fire:Fire fighting",
"Fire:Fire risk reduction"
],
"keyword": [
"Flashover Prediction; Recurrent Neural Network; Validation with Experimental Data; Smart Fire Fighting"
]
}