This dataset includes files generated from post-build X-ray computed tomography (XCT) measurements of the four parts built as part of the "Overhang Part X4" in-situ process monitoring dataset (available at https://doi.org/10.18434/M32233). The "Overhang Part X4" dataset was a three-dimensional (3D) additive manufacturing (AM) build performed on the Additive Manufacturing Metrology Testbed (AMMT) by Ho Yeung and Brandon Lane on June 28, 2019. The files in this dataset include XCT image sequences for each part, and stereolithography files (.STL) of the surface data extracted from XCT, measured by Maxwell Praniewicz at the Precision Machining Research Consortium at Georgia Institute of Technology, Atlanta, GA.
About this Dataset
Title | X-ray computed tomography data of Additive Manufacturing Metrology Testbed (AMMT) parts: Overhang Part X4 |
---|---|
Description | This dataset includes files generated from post-build X-ray computed tomography (XCT) measurements of the four parts built as part of the "Overhang Part X4" in-situ process monitoring dataset (available at https://doi.org/10.18434/M32233). The "Overhang Part X4" dataset was a three-dimensional (3D) additive manufacturing (AM) build performed on the Additive Manufacturing Metrology Testbed (AMMT) by Ho Yeung and Brandon Lane on June 28, 2019. The files in this dataset include XCT image sequences for each part, and stereolithography files (.STL) of the surface data extracted from XCT, measured by Maxwell Praniewicz at the Precision Machining Research Consortium at Georgia Institute of Technology, Atlanta, GA. |
Modified | 2020-08-10 00:00:00 |
Publisher Name | National Institute of Standards and Technology |
Contact | mailto:[email protected] |
Keywords | Additive Manufacturing; Laser powder bed fusion; x-ray computed tomography; |
{ "identifier": "ark:\/88434\/mds2-2291", "accessLevel": "public", "contactPoint": { "hasEmail": "mailto:[email protected]", "fn": "Brandon Lane" }, "programCode": [ "006:045" ], "landingPage": "https:\/\/data.nist.gov\/od\/id\/mds2-2291", "title": "X-ray computed tomography data of Additive Manufacturing Metrology Testbed (AMMT) parts: Overhang Part X4", "description": "This dataset includes files generated from post-build X-ray computed tomography (XCT) measurements of the four parts built as part of the \"Overhang Part X4\" in-situ process monitoring dataset (available at https:\/\/doi.org\/10.18434\/M32233). The \"Overhang Part X4\" dataset was a three-dimensional (3D) additive manufacturing (AM) build performed on the Additive Manufacturing Metrology Testbed (AMMT) by Ho Yeung and Brandon Lane on June 28, 2019. The files in this dataset include XCT image sequences for each part, and stereolithography files (.STL) of the surface data extracted from XCT, measured by Maxwell Praniewicz at the Precision Machining Research Consortium at Georgia Institute of Technology, Atlanta, GA.", "language": [ "en" ], "distribution": [ { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4_Part1_Cropped.zip", "mediaType": "application\/zip" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4_Part1_Cropped.zip.sha256", "mediaType": "text\/plain" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4_Part2_Cropped.zip", "mediaType": "application\/zip" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4_Part2_Cropped.zip.sha256", "mediaType": "text\/plain" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4_Part3%20Cropped.zip", "mediaType": "application\/zip" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4_Part3%20Cropped.zip.sha256", "mediaType": "text\/plain" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4_Part4%20Cropped.zip", "mediaType": "application\/zip" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4_Part4%20Cropped.zip.sha256", "mediaType": "text\/plain" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4%20Part1%20Surface_cleaned.zip", "mediaType": "application\/zip" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4%20Part1%20Surface_cleaned.zip.sha256", "mediaType": "text\/plain" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4%20Part2%20Surface_cleaned.zip", "mediaType": "application\/zip" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4%20Part2%20Surface_cleaned.zip.sha256", "mediaType": "text\/plain" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4%20Part3%20Surface_cleaned.zip", "mediaType": "application\/zip" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4%20Part3%20Surface_cleaned.zip.sha256", "mediaType": "text\/plain" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4%20Part4%20Surface_cleaned.zip", "mediaType": "application\/zip" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/ark:\/88434\/mds2-2291\/OverhangPartX4%20Part4%20Surface_cleaned.zip.sha256", "mediaType": "text\/plain" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2291\/OverhangPart_9x5x5mm.STL", "mediaType": "application\/octet-stream" }, { "downloadURL": "https:\/\/data.nist.gov\/od\/ds\/mds2-2291\/OverhangPart_9x5x5mm.STL.sha256", "mediaType": "text\/plain" }, { "accessURL": "https:\/\/doi.org\/10.18434\/mds2-2291", "title": "DOI Access for X-ray computed tomography data of Additive Manufacturing Metrology Testbed (AMMT) parts: Overhang Part X4" } ], "bureauCode": [ "006:55" ], "modified": "2020-08-10 00:00:00", "publisher": { "@type": "org:Organization", "name": "National Institute of Standards and Technology" }, "theme": [ "Manufacturing:Additive manufacturing" ], "keyword": [ "Additive Manufacturing; Laser powder bed fusion; x-ray computed tomography;" ] }