U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

83 results found

SRM 972a Vitamin D Metabolites in Frozen Human Serum

Data provided by  National Institute of Standards and Technology

SRM 972a Vitamin D Metabolites in Frozen Human Serum - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 972a,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 999c Potassium Chloride (High-Purity Chemical)

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as an analytical standard of known potassium (K) and chloride (Cl-) content. This lot of potassium chloride (KCl) was prepared to ensure a material of high purity and homogeneity and has been assayed after drying at 500 °C. A unit of SRM 999c consists of a single glass bottle containing 30 g of the material. This data is public in the Certificate of Analysis for this material.

Tags: high purity chemical,clinical,Standard Reference Material,SRM,potassium chloride,potassium,chloride,Food and Nutrition,

Modified: 2024-02-22

Views: 0

SRM 1721 Southern Oceanic Air (Ambient Nominal Amount-of-Substance Fraction: Carbon Dioxide, Methane, Nitrous Oxide)

Data provided by  National Institute of Standards and Technology

Standard Reference Material-1721: Southern Oceanic Air. Ambient Nominal Amount of Substance Fraction for Carbon Dioxide, Methane & Nitrous Oxide. This Standard Reference Material (SRM) is a primary gas mixture for which the amount-of-substance fraction, expressed as concentration, may be related to secondary working standards. This SRM is intended for the calibration of instruments used for ambient carbon dioxide (CO2), methane (CH4) and nitrous oxide (N2O) determinations and for other applications. This data is public in the Certificate of Analysis for this material.

Tags: SRM,Standard Reference Material,Southern Oceanic Air,carbon dioxide,methane,Nitrous Oxide,CO2,CH4,N2O,amount of substance,Energy,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 918c Potassium Chloride General and Ion Activity Standard

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as an analytical standard of known purity. It is intended primarily for use in the calibration and standardization of procedures for potassium (K) and chloride (Cl-) determinations employed in clinical analysis, including those using ion-selective electrodes, and for routine critical evaluation of the daily working standards used in these procedures. This lot of potassium chloride (KCl) was prepared to ensure a material of high purity and homogeneity and has been assayed after heating at 110 degrees C to 120 degrees C.

Tags: SRM,Standard Reference Material,potassium chloride,

Modified: 2024-02-22

Views: 0

Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Centroid Data measured between 3.6 degrees C and 25.4 degrees C for the Fab Fragment of NISTmAb

Data provided by  National Institute of Standards and Technology

The spreadsheet file reported herein provides centroid data, descriptive of deuterium uptake, for the Fab Fragment of NISTmAb (PDB: 5K8A) reference material, as measured by the bottom-up hydrogen-deuterium exchange mass spectrometry (HDX-MS) method. The protein sample was incubated in deuterium-rich solutions under uniform pH and salt concentrations between 3.6 degrees C and 25.4 degrees C for seven intervals ranging (0 to 14,400) s plus a control sample that simulates a Fab Fragment immersed for infinite time in D2O.

Tags: hydrogen-deuterium exchange,hydrogen exchange,HDX-MS,interlaboratory comparison,mass spectrometry,peptide,precision,proteomics,reference material,repeatability,reproducibility,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the Fc(gamma)RIa (CD64) Receptor

Data provided by  National Institute of Standards and Technology

This database gives hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, Fc(gamma)RIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.

Tags: antibody-receptor interaction,chromatography,HDX-MS,hydrogen-deuterium exchange,glycosylation,mass spectrometry,monoclonal antibody,precision,peptide,protein,proteolysis,proteomics,receptor.,

Modified: 2024-02-22

Views: 0

NIST Thermophysical Properties of Hydrocarbon Mixtures Database- SRD 4

Data provided by  National Institute of Standards and Technology

SUPERTRAPP is an interactive computer program for predicting thermodynamic and transport properties of pure fluids and fluid mixtures containing up to 20 components. The components are selected from a database of 210 components, mostly hydrocarbons. SUPERTRAPP performs phase equilibria calculations and gives the thermophysical properties of all phases and the feed.

Tags: Lennard Jones,butenes,chemical engineering,chemistry,equations of state,flash calculations,fluids,gaseous,gases,hydrocarbons,liquidus,mixtures,natural gases,petrochemicals,phase equilibria,physics,supercritical fluids,thermo chemistry,thermo physical,thermochemical data,thermodynamic data,thermodynamic properties,thermodynamics,thermophysics,transport properties,transport property data,

Modified: 2024-02-22

Views: 0

NIST XCOM: Photon Cross Sections Database - SRD 8

Data provided by  National Institute of Standards and Technology

A web database is provided which can be used to calculate photon cross sections for scattering, photoelectric absorption and pair production, as well as total attenuation coefficients, for any element, compound or mixture (Z <= 100) at energies from 1 keV to 100 GeV. XCOM provides two forms of output: (a) tables which correspond closely in format to existing tables in the literature; (b) graphical display of the tabular data.

Tags: X rays,Xrays,bremsstrahlung,electron pair productions,elements,energies,gamma rays,mixtures,nuclear pair productions,nuclear physics,photons,physics,total attenuation coefficients,

Modified: 2024-02-22

Views: 0

NIST/ASME Steam Properties Database - SRD 10

Data provided by  National Institute of Standards and Technology

The NIST/ASME Steam Properties Database is based upon the International Association for the Properties of Water and Steam (IAPWS) 1995 formulation for general and scientific use for the thermodynamic properties of water, this updated version provides water properties from the international standards over a wide range of conditions. Version 3.0 incorporates new IAPWS standards adopted in 2008 for the viscosity and for the melting and sublimation curves and in 2011 for the thermal conductivity.

Tags: chemical engineering,chemistry,dielectric,energies,equations of state,fluids,gas phases,liquid phases,phase equilibria,physics,properties of water,refractive index,refractivity,steam tables,supercritical,thermodynamic data,thermodynamic properties,thermodynamics,thermophysical,thermophysics,transport properties,transport property data,

Modified: 2024-02-22

Views: 0