U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

65 results found

SRM 918c Potassium Chloride General and Ion Activity Standard

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as an analytical standard of known purity. It is intended primarily for use in the calibration and standardization of procedures for potassium (K) and chloride (Cl-) determinations employed in clinical analysis, including those using ion-selective electrodes, and for routine critical evaluation of the daily working standards used in these procedures. This lot of potassium chloride (KCl) was prepared to ensure a material of high purity and homogeneity and has been assayed after heating at 110 degrees C to 120 degrees C.

Tags: SRM,Standard Reference Material,potassium chloride,

Modified: 2024-02-22

Views: 0

NIST Micronutrients Measurement Quality Assurance Program Winter and Summer 2017 Comparability Studies

Data provided by  National Institute of Standards and Technology

The Micronutrients Measurement Quality Assurance Program (MMQAP) was coordinated by the Chemical Sciences Division and supported measurement technology for selected fat- and water-soluble vitamins and carotenoids in human serum. This program was initiated in 1984 by the National Cancer Institute Division of Cancer Prevention and Control to ensure the long-term reliability of the measurements made while studying the possible cancer chemoprevention roles of these compounds.

Tags: interlaboratory comparisons,Biosciences and Health,Energy,Environment and Climate,Food and Nutrition,fat-soluble vitamins,Carotenoids,Vitamin C,Human Serum,interlaboratory study,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

Datasets from an interlaboratory comparison to characterize a multi-modal polydisperse sub-micrometer bead dispersion

Data provided by  National Institute of Standards and Technology

These four data files contain datasets from an interlaboratory comparison that characterized a polydisperse five-population bead dispersion in water. A more detailed version of this description is available in the ReadMe file (PdP-ILC_datasets_ReadMe_v1.txt), which also includes definitions of abbreviations used in the data files. Paired samples were evaluated, so the datasets are organized as pairs associated with a randomly assigned laboratory number.

Tags: Biosciences and Health,particle,protein particle,sub-micrometer particle,subvisible particle,particle tracking analysis,resonant mass measurement,electrical sensing zone,holographic particle characterization,flow imaging,laser diffraction,flow cytometry,

Modified: 2024-02-22

Views: 0

NIST MEMS Calculator - SRD 166

Data provided by  National Institute of Standards and Technology

This MEMS Calculator determines the following thin film properties from data taken with an optical interferometer or comparable instrument: a) residual strain from fixed-fixed beams, b) strain gradient from cantilevers, c) step heights or thicknesses from step-height test structures, and d) in-plane lengths or deflections. Then, residual stress and stress gradient calculations can be made after an optical vibrometer or comparable instrument is used to obtain Young's modulus from resonating cantilevers or fixed-fixed beams.

Tags: ASTM,MEMS 5 in 1,MEMS Calculators,Micro Electro Mechanical Systems,Semiconductor Equipment and Materials International,Standard Reference Material,Young's modulus measurements,cantilevers,data analysis sheets,fixed-fixed beams,height measurements,interferometries,length measurements,residual strains,residual stresses,steps,strain gradients,stress gradients,test structures,thick,vibrometries,

Modified: 2024-02-22

Views: 0

Commutability assessment of selected SRMs

Data provided by  National Institute of Standards and Technology

Interlaboratory data from assessments of SRMs and other method comparison samples

Tags: Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 131h Refined Cast Iron

Data provided by  National Institute of Standards and Technology

Standard Reference Material 131h Refined Cast Iron - This Standard Reference Material (SRM) is intended primarily for use in validation of chemical and instrumental methods of analysis. It can be used to validate value assignment of in-house reference materials and, if necessary, to calibrate carbon/sulfur analyzers. A unit of SRM 131h consists of a bottle containing 100 g of chips. This data is public in the Certificate of Analysis for this material.

Tags: low alloy steel,cast iron,carbon,sulfur,Standard Reference Material,SRM,SRM 131h,combustion,infrared detection,manufacturing specification,manufacturing,

Modified: 2024-02-22

Views: 0

SRM 1632d Trace Elements in Coal (Bituminous)

Data provided by  National Institute of Standards and Technology

Standard Reference Material 1632d Trace Elements in Coal (Bituminous) - This Standard Reference Material (SRM) is intended primarily for use in the evaluation of techniques used in the analysis of coals and materials of a similar matrix. A unit of SRM 1632d consists of 50 g of bituminous coal that was ground to pass a 250 µm (60 mesh) sieve, homogenized, bottled under an argon atmosphere, and sealed in an aluminized bag. This data is public in the Certificate of Analysis for this material.

Tags: SRM,Standard Reference Material,coal,sulfur,mercury,chlorine,trace elements,Energy,

Modified: 2024-02-22

Views: 0

SRM 1632e Trace Elements in Coal (Bituminous)

Data provided by  National Institute of Standards and Technology

SRM 1632e Trace Elements in Coal (Bituminous) - This Standard Reference Material (SRM) is intended primarily for use in the evaluation of techniques used in the analysis of coals and materials of a similar matrix.

Tags: Standard Reference Material,SRM,trace elements,sulfur,mercury,chlorine,Energy,

Modified: 2024-02-22

Views: 0

SRM 1633c Trace Elements in Coal Fly Ash

Data provided by  National Institute of Standards and Technology

SRM 1633c Trace Elements in Coal Fly Ash - This Standard Reference Material (SRM) is intended for use in the evaluation of analytical methods for the determination of constituent elements in coal fly ash or materials of a similar matrix. SRM 1633c is a bituminous coal fly ash that was sieved through a nominal sieve opening of 74 µm (200 mesh) and then blended to assure homogeneity. A unit of SRM 1633c consists of 75 g of powdered material. This data is public in the Certificate of Analysis for this material.

Tags: SRM,Standard Reference Material,coal fly ash,sulfur,mercury,chlorine,trace elements,Energy,

Modified: 2024-02-22

Views: 0