U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

47 results found

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

Construction of a Dual-enzyme, Subzero (-30 degree C) Chromatography System and Multi-channel Precision Temperature Controller for Hydrogen-Deuterium Exchange Mass Spectrometry

Data provided by  National Institute of Standards and Technology

This tutorial provides mechanical drawings, electrical schematics, parts lists, STL files for 3D-printed parts, IGS files, and instructions for automated machining necessary for construction of a dual-protease, subzero, liquid chromatography system for hydrogen-deuterium exchange mass spectrometry. Electrical schematics for construction of a multi-zone temperature controller that regulate to ±0.1 oC are also included in this tutorial.

Tags: liquid chromatography,hydrogen-deuterium exchange,mass spectrometry,precision,peptide,protein,proteolysis,proteomics,reference material,temperature control.,

Modified: 2024-02-22

Views: 0

Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Centroid Data measured between 3.6 degrees C and 25.4 degrees C for the Fab Fragment of NISTmAb

Data provided by  National Institute of Standards and Technology

The spreadsheet file reported herein provides centroid data, descriptive of deuterium uptake, for the Fab Fragment of NISTmAb (PDB: 5K8A) reference material, as measured by the bottom-up hydrogen-deuterium exchange mass spectrometry (HDX-MS) method. The protein sample was incubated in deuterium-rich solutions under uniform pH and salt concentrations between 3.6 degrees C and 25.4 degrees C for seven intervals ranging (0 to 14,400) s plus a control sample that simulates a Fab Fragment immersed for infinite time in D2O.

Tags: hydrogen-deuterium exchange,hydrogen exchange,HDX-MS,interlaboratory comparison,mass spectrometry,peptide,precision,proteomics,reference material,repeatability,reproducibility,

Modified: 2024-02-22

Views: 0

NIST Atomic Spectra Database - SRD 78

Data provided by  National Institute of Standards and Technology

This database provides access and search capability for NIST critically evaluated data on atomic energy levels, wavelengths, and transition probabilities that are reasonably up-to-date. The Atomic Spectroscopy Data Center has carried out these critical compilations. The Data Center is located in the Physical Measurement Laboratory at the National Institute of Standards and Technology (NIST).

Tags: cesium,chlorine,chromium,cobalt,columbium,copernicium,copper,curium,darmstadtium,database,deuterium,doubly-charged,dubnium,dysprosium,einsteinium,element,energy levels,erbium,europium,fermium,flerovium,fluorine,francium,gadolinium,gallium,germanium,gold,ground states,hafnium,hassium,helium,holmium,hydrogen,indium,iodine,ionization potentials,ionization-energies,ionization-limits,ionized-atoms,iridium,iron,mendelevium,mercury,molybdenum,multiply-charged,neodymium,neon,neptunium,neutral,nickel,niobium,nitrogen,nobelium,osmium,oxygen,palladium,phosphorus,platinum,plutonium,polonium,potassium,praseodymium,promethium,protactinium,quadruply-charged,radium,rhenium,rhodium,roentgenium,rubidium,ruthenium,rutherfordium,samarium,scandium,seaborgium,selenium,silicium,silicon,silver,singly-charged,sodium,spectra,spectral lines,spectroscopy,spectrum,strontium,sulfur,sulphur,tantalum,technetium,tellurium,terbium,thallium,thorium,thulium,tin,titanium,transition probabilities,triply-charged,tritium,tungsten,ununbium,ununhexium,ununoctium,ununpentium,ununquadium,ununseptium,ununtrium,unununium,uranium,vanadium,wavelengths,xenon,ytterbium,yttrium,zinc,zirconium,krypton,kurchatovium,lawrencium,lanthanum,lead,lithium,livermorium,lutetium,magnesium,manganese,meitnerium,Atomic,Atomic Spectroscopy,Radon,actinium,aluminium,aluminum,americium,antimony,argon,arsenic,astatine,atom,atomic physics,atomic property,atomic-ions,barium,berkelium,beryllium,bismuth,bohrium,boron,bromine,cadmium,calcium,californium,carbon,cerium,

Modified: 2024-02-22

Views: 0

SRM 2585 Organic Contaminants in House Dust

Data provided by  National Institute of Standards and Technology

SRM 2585 Organic Contaminants in House Dust - This Standard Reference Material (SRM) is intended for use in evaluating analytical methods for the determination of selected polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, and polybrominated diphenyl ether (PBDE) congeners in house dust and similar matrices. All of the constituents for which certified, reference, and information values are provided in SRM 2585 were naturally present in the dust material before processing.

Tags: Standard Reference Material,SRM,SRM 2585,House Dust,certified values,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 972a Vitamin D Metabolites in Frozen Human Serum

Data provided by  National Institute of Standards and Technology

SRM 972a Vitamin D Metabolites in Frozen Human Serum - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 972a,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 1632d Trace Elements in Coal (Bituminous)

Data provided by  National Institute of Standards and Technology

Standard Reference Material 1632d Trace Elements in Coal (Bituminous) - This Standard Reference Material (SRM) is intended primarily for use in the evaluation of techniques used in the analysis of coals and materials of a similar matrix. A unit of SRM 1632d consists of 50 g of bituminous coal that was ground to pass a 250 µm (60 mesh) sieve, homogenized, bottled under an argon atmosphere, and sealed in an aluminized bag. This data is public in the Certificate of Analysis for this material.

Tags: SRM,Standard Reference Material,coal,sulfur,mercury,chlorine,trace elements,Energy,

Modified: 2024-02-22

Views: 0

SRM 1633c Trace Elements in Coal Fly Ash

Data provided by  National Institute of Standards and Technology

SRM 1633c Trace Elements in Coal Fly Ash - This Standard Reference Material (SRM) is intended for use in the evaluation of analytical methods for the determination of constituent elements in coal fly ash or materials of a similar matrix. SRM 1633c is a bituminous coal fly ash that was sieved through a nominal sieve opening of 74 µm (200 mesh) and then blended to assure homogeneity. A unit of SRM 1633c consists of 75 g of powdered material. This data is public in the Certificate of Analysis for this material.

Tags: SRM,Standard Reference Material,coal fly ash,sulfur,mercury,chlorine,trace elements,Energy,

Modified: 2024-02-22

Views: 0

SRM 1635a Trace Elements in Coal (Subbituminous)

Data provided by  National Institute of Standards and Technology

SRM 1635a Trace Elements in Coal (Subbituminous) - This Standard Reference Material (SRM) is intended primarily for the evaluation of techniques used in the analysis of coals and materials of a similar matrix. A unit of SRM 1635a consists of 50 g of subbituminous coal that was ground to pass a 250 µm (60 mesh) sieve, homogenized, bottled under an argon atmosphere, and sealed in an aluminized bag. This data is public in the Certificate of Analysis for this material.

Tags: SRM,Standard Reference Material,coal,sulfur,mercury,chlorine,trace elements,Energy,

Modified: 2024-02-22

Views: 0