U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

37 results found

High accuracy spectroscopic parameters of the 1.27 um band of O2 measured with comb-referenced, cavity ring-down spectroscopy

Data provided by  National Institute of Standards and Technology

Data corresponding to Figs. 2,3,5,6,11,12,13,14 for Fleurbaey et al J. Quant Spectrosc. Radiat. Transf. vol 270, 107684 (2021). doi.org.10.1016/j.jqsrt.2021.107684

Tags: greenhouse gases,carbon dioxide,oceans,ph,marine mammals,remote sensing,seabirds,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 2969 Vitamin D Metabolites in Frozen Human Serum (Total 25-Hydroxyvitamin D Low Level) Data

Data provided by  National Institute of Standards and Technology

SRM 2969 Electronic files containing certified values and their uncertainties, and the data used to assign those values

Tags: vitamin D,25-hydroxyvitamin D,serum,mass spectrometry,

Modified: 2024-02-22

Views: 0

SRM 2970 Vitamin D Metabolites in Frozen Human Serum (25-Hydroxyvitamin D2 High Level) Data

Data provided by  National Institute of Standards and Technology

Electronic files containing certified values and their uncertainties, and the data used to assign those values.

Tags: vitamin D,25-hydroxyvitamin D,serum,mass spectrometry,

Modified: 2024-02-22

Views: 0

MAM Consortium Interlaboratory Study Raw Data

Data provided by  National Institute of Standards and Technology

These LC-MS and LC-MS/MS raw data were collected for purposes of an interlaboratory study evaluating the multi-attribute method (MAM). Tryptic digests of native NISTmAb (the "Reference" and the "Unknown" samples), degraded NISTmAb (the "pH Stress" sample) and NISTmAb spiked with 15 heavy-labeled synthetic peptides (the "Spike" sample) were sent to each participating laboratory. One injection of each digest was acquired in MS-only mode, while a second injection was acquired in MS/MS mode.

Tags: attribute analytics,interlaboratory study,multi-attribute method,MAM Consortium,mass spectrometry,new peak detection,NPD,purity testing,round robin,targeted analytics,NISTmAb,

Modified: 2024-02-22

Views: 0

Data from Laboratory Tests of a Prototype Carbon Dioxide Ground-Source Air Conditioner

Data provided by  National Institute of Standards and Technology

These data from the laboratory tests of a prototype residential liquid-to-air ground-source air conditioner (GSAC) using CO2 as the refrigerant. The data collection and processing methods are described in detail in this report:

Report Title: "Laboratory Tests of a Prototype Carbon Dioxide Ground-Source Air Conditioner", NIST Technical Note 2068
Publication Date: October 2019
DOI: https://doi.org/10.6028/NIST.TN.2068
Authors: Harrison Skye, Wei Wu

Tags: Air conditioner,carbon dioxide,CO2,ground-source heat pump,subcritical and transcritical cycles,

Modified: 2024-02-22

Views: 0

Construction of a Dual-enzyme, Subzero (-30 degree C) Chromatography System and Multi-channel Precision Temperature Controller for Hydrogen-Deuterium Exchange Mass Spectrometry

Data provided by  National Institute of Standards and Technology

This tutorial provides mechanical drawings, electrical schematics, parts lists, STL files for 3D-printed parts, IGS files, and instructions for automated machining necessary for construction of a dual-protease, subzero, liquid chromatography system for hydrogen-deuterium exchange mass spectrometry. Electrical schematics for construction of a multi-zone temperature controller that regulate to ±0.1 oC are also included in this tutorial.

Tags: liquid chromatography,hydrogen-deuterium exchange,mass spectrometry,precision,peptide,protein,proteolysis,proteomics,reference material,temperature control.,

Modified: 2024-02-22

Views: 0

High Accuracy Near-infrared Carbon Dioxide Intensity Measurements to Support Remote Sensing

Data provided by  National Institute of Standards and Technology

Data files for the publication "High Accuracy Near-infrared Carbon Dioxide Intensity Measurements to Support Remote Sensing" in Geophysical Research Letters

Tags: greenhouse gases,carbon dioxide,remote sensing,

Modified: 2024-02-22

Views: 0

Development of a Tool to Determine the Variability of Consensus Mass Spectra Supporting Data

Data provided by  National Institute of Standards and Technology

Supporting datasets and algorithms (R-based) for the manuscript entitled "Development of a Tool to Determine the Variability of Consensus Mass Spectra", including an R Markdown script to reproduce the manuscript's figures.

Tags: mass spectrometry,uncertainty analysis,per- and polyfluoroalkyl substances,PFAS,reference mass spectrum,

Modified: 2024-02-22

Views: 0

SRM 1721 Southern Oceanic Air (Ambient Nominal Amount-of-Substance Fraction: Carbon Dioxide, Methane, Nitrous Oxide)

Data provided by  National Institute of Standards and Technology

Standard Reference Material-1721: Southern Oceanic Air. Ambient Nominal Amount of Substance Fraction for Carbon Dioxide, Methane & Nitrous Oxide. This Standard Reference Material (SRM) is a primary gas mixture for which the amount-of-substance fraction, expressed as concentration, may be related to secondary working standards. This SRM is intended for the calibration of instruments used for ambient carbon dioxide (CO2), methane (CH4) and nitrous oxide (N2O) determinations and for other applications. This data is public in the Certificate of Analysis for this material.

Tags: SRM,Standard Reference Material,Southern Oceanic Air,carbon dioxide,methane,Nitrous Oxide,CO2,CH4,N2O,amount of substance,Energy,Environment and Climate,

Modified: 2024-02-22

Views: 0

Hestia Fossil Fuel Carbon Dioxide Emissions Inventory for Los Angeles Basin

Data provided by  National Institute of Standards and Technology

Hestia Project quantifies, simulates and visualizes greenhouse gases such as carbon dioxide emitted in urban regions. Los Angeles basin activity is provided at the 1 km grid spatial resolution, and at temporal resolutions of hourly or annually. Hestia-LA urban CO2 emissions inventory builds upon work conducted at the national scale (Vulcan Project) that includes various sectorial attributions. Hestia's high spatial and temporal resolution datasets are currently available for 2010 to 2015, in UTC or local time.

Tags: Greenhouse Gas,carbon dioxide,CO2,Urban Emissions,Carbon Monitoring,Atmospheric Modeling,Los Angeles Basin,California,Megacities,Fossil Fuel,Bottom-up Emissions Inventory,

Modified: 2024-02-22

Views: 0