U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

54 results found

Certified values of iodine in CRMs of food matrices in mg/kg units. The uncertainties are expanded uncertainties at approximately 95% confidence.

Data provided by  National Institute of Standards and Technology

A comparison of the expanded uncertainty for certified values of iodine in food matrix CRMs. The CRMS were found by searching The European Virtual Institute for Speciation Analysis (EVISA) database using the terms "Iodine" and "Certified" in the Material category. The uncertainties are expanded uncertainties at approximately 95% confidence.

Tags: food,nutrition,dietary supplements,Standard Reference materials,reference materials,SRM,RM,Food and Nutrition,

Modified: 2024-02-22

Views: 0

SRM 2378 Fatty Acids in Human Serum

Data provided by  National Institute of Standards and Technology

Donor serum for SRM 2378 was collected from three groups of individuals: (level 1) three healthy donors who took 1000 mg/day of fish oil supplements for a minimum of one month prior to collection; (level 2) three healthy donors who took 1000 mg/day of flaxseed oil supplements for a minimum of one month prior to collection; and (level 3) three healthy donors who did not take either fish or flaxseed oil supplements for one month prior to collection.

Tags: fatty acids,serum,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 972a Vitamin D Metabolites in Frozen Human Serum

Data provided by  National Institute of Standards and Technology

SRM 972a Vitamin D Metabolites in Frozen Human Serum - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 972a,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level)

Data provided by  National Institute of Standards and Technology

SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level) - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 2973,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 3163 Tungsten (W) Standard Solution, Lot No. 140606

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of tungsten. A unit of SRM 3163 consists of 50 mL of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of tungsten in a high-density polyethylene bottle sealed in an aluminized bag.

Tags: tungsten,pure materials,cations,single-element solutions,spectrometry,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 3239 Isoflavones Calibration Solution

Data provided by  National Institute of Standards and Technology

SRM 3239 Isoflavones Calibration Solution - This Standard Reference Material (SRM) is intended primarily for use in calibration of instruments and techniques used for the determination of isoflavones. SRM 3239 consists of two solutions containing isoflavones at levels that reflect the mass fraction ratios found in soy products. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 3239,certified values,nutrition,dietary supplements,isoflavones,Food and Nutrition,

Modified: 2024-02-22

Views: 0

SRM 2193a Calcium Carbonate pH Standard [used as saturated Ca(OH)2 solution]

Data provided by  National Institute of Standards and Technology

SRM 2193a Calcium Carbonate pH Standard [used as saturated Ca(OH)2 solution] - This Standard Reference Material (SRM) is intended for use in preparing solutions for calibrating electrodes for pH measuring systems at pH values above 11.0. This lot of calcium carbonate (CaCO3) was selected for its low level of alkali metal impurities. However, this SRM is certified ONLY as a pH standard, NOT as a pure substance. A unit of SRM 2193a consists of 30 g of CaCO3. This data is public in the Certificate of Analysis for this material.

Tags: Biosciences and Health,Environment and Climate,Food and Nutrition,

Modified: 2024-02-22

Views: 0

SRM 3669 Arsenic Species in Frozen Human Urine (Elevated Levels)

Data provided by  National Institute of Standards and Technology

SRM 3669 Arsenic Species in Frozen Human Urine (Elevated Levels) - This Standard Reference Material (SRM) is intended primarily for validating analytical methods and measurements for the determination of arsenic species in human urine. A unit of SRM 3669 consists of five pouches each containing a vial of arsenic species in frozen human urine at elevated levels. Each vial contains nominally 1.5 mL of urine. This data is public in the Certificate of Analysis for this material.

Tags: SRM 3669,arsenic,arsenic species,urine,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 2950a Respirable Alpha Quartz on Filter Media (Nominal Mass of Alpha Quartz: 5 µg to 500 µg)

Data provided by  National Institute of Standards and Technology

SRM 2950a Respirable Alpha Quartz on Filter Media (Nominal Mass of Alpha Quartz: 5 µg to 500 µg) - This Standard Reference Material (SRM) is intended primarily for the calibration of X-ray diffraction (XRD) spectrometers for the determination of respirable alpha quartz using National Institute for Occupational Safety and Health (NIOSH) Method 7500, or the equivalent. This data is public in the Certificate of Analysis for this material.

Tags: SRM 2950a,respirable,alpha quartz,filter,SRM,Standard Reference Material,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 968f Fat-Soluble Vitamins in Human Serum

Data provided by  National Institute of Standards and Technology

Standard Reference Material (SRM) 968 and its reissues are human serum based materials used as validation standards by clinical, epidemiological, and nutrition laboratories. Historically, about 300 units of this SRM have been sold annually. Based on this annual sales projection, as of November 1, 2015 there were about 16 months of inventory of the current issue: SRM 968e Fat-Soluble Vitamins, Carotenoids, and Cholesterol in Human Serum.

Tags: fat-soluble vitamins,clinical,Frozen Human Serum,Biosciences and Health,

Modified: 2024-02-22

Views: 0