56 results found

Datasets from an interlaboratory comparison to characterize a multi-modal polydisperse sub-micrometer bead dispersion

Data provided by  National Institute of Standards and Technology

These four data files contain datasets from an interlaboratory comparison that characterized a polydisperse five-population bead dispersion in water. A more detailed version of this description is available in the ReadMe file (PdP-ILC_datasets_ReadMe_v1.txt), which also includes definitions of abbreviations used in the data files. Paired samples were evaluated, so the datasets are organized as pairs associated with a randomly assigned laboratory number.

Tags: Biosciences and Health,particle,protein particle,sub-micrometer particle,subvisible particle,particle tracking analysis,resonant mass measurement,electrical sensing zone,holographic particle characterization,flow imaging,laser diffraction,flow cytometry,

Modified: 2024-02-22

Views: 0

MAM Consortium Interlaboratory Study Raw Data

Data provided by  National Institute of Standards and Technology

These LC-MS and LC-MS/MS raw data were collected for purposes of an interlaboratory study evaluating the multi-attribute method (MAM). Tryptic digests of native NISTmAb (the "Reference" and the "Unknown" samples), degraded NISTmAb (the "pH Stress" sample) and NISTmAb spiked with 15 heavy-labeled synthetic peptides (the "Spike" sample) were sent to each participating laboratory. One injection of each digest was acquired in MS-only mode, while a second injection was acquired in MS/MS mode.

Tags: attribute analytics,interlaboratory study,multi-attribute method,MAM Consortium,mass spectrometry,new peak detection,NPD,purity testing,round robin,targeted analytics,NISTmAb,

Modified: 2024-02-22

Views: 0

Construction of a Dual-enzyme, Subzero (-30 degree C) Chromatography System and Multi-channel Precision Temperature Controller for Hydrogen-Deuterium Exchange Mass Spectrometry

Data provided by  National Institute of Standards and Technology

This tutorial provides mechanical drawings, electrical schematics, parts lists, STL files for 3D-printed parts, IGS files, and instructions for automated machining necessary for construction of a dual-protease, subzero, liquid chromatography system for hydrogen-deuterium exchange mass spectrometry. Electrical schematics for construction of a multi-zone temperature controller that regulate to ±0.1 oC are also included in this tutorial.

Tags: liquid chromatography,hydrogen-deuterium exchange,mass spectrometry,precision,peptide,protein,proteolysis,proteomics,reference material,temperature control.,

Modified: 2024-02-22

Views: 0

Aggregation of Purified Protein Reference Materials Characterized by Asymmetric Flow Field Flow Fractionation

Data provided by  National Institute of Standards and Technology

This is a file containing aggregation data for two proteins that were thermomechanically aggregated. The aggregated proteins were separated by asymmetric flow field flow fractionation and separated protein fractions were detected and quantified by UV spectrophotometry and multi-angle light scattering. The UV spectrophotometry was used to quantify the amount of residual monomer, which is reported herein. The multi-angle light scattering was fitted to a relevant model to calculate the molecular weight of the aggregated protein, also reported herein.

Tags: electrical sensing zone,flow imaging,light obscuration,particle,protein aggregate,protein particle,subvisible particle,visible particle,Biosciences and Health,

Modified: 2024-02-22

Views: 0

Development of a Tool to Determine the Variability of Consensus Mass Spectra Supporting Data

Data provided by  National Institute of Standards and Technology

Supporting datasets and algorithms (R-based) for the manuscript entitled "Development of a Tool to Determine the Variability of Consensus Mass Spectra", including an R Markdown script to reproduce the manuscript's figures.

Tags: mass spectrometry,uncertainty analysis,per- and polyfluoroalkyl substances,PFAS,reference mass spectrum,

Modified: 2024-02-22

Views: 0

SRM 3104a Barium (Ba) Standard Solution Lot No. 140909

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of barium. A unit of SRM 3104a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of barium. The solution contains nitric acid at a volume fraction of approximately 1 %, which is equivalent to a concentration (molarity) of approximately 0.16 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: barium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3110 Cerium (Ce) Standard Solution Lot No. 160830

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of cerium. A unit of SRM 3110 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of cerium. The solution contains nitric acid at a mass fraction of approximately 16 %. This data is public in the Certificate of Analysis for this material.

Tags: cerium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3120a Germanium (Ge) Standard Solution Lot No. 080429

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of germanium. A unit of SRM 3120a consists of 50 mL of a single element solution in a high density polyethylene bottle sealed in an aluminized bag. The solution was prepared gravimetrically to contain a known mass fraction of germanium. The solution contains nitric acid at a concentration of approximately 1.6 mol/L and hydrofluoric acid at a concentration of approximately 0.6 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: germanium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3122 Hafnium (Hf) Standard Solution Lot No. 151120

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of hafnium. A unit of SRM 3122 consists of 50 mL of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of hafnium in a high density polyethylene bottle sealed in an aluminized bag. The solution contains approximately 8 % nitric acid (volume fraction) and approximately 1 % hydrofluoric acid (volume fraction), equivalent to amount of substance concentrations (molarities) of 1.3 mol/L and 0.3 mol/L, respectively.

Tags: hafnium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3127a Lanthanum (La) Standard Solution Lot No. 151030

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of lanthanum. A unit of SRM 3127a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of lanthanum. The solution contains nitric acid at a volume fraction of approximately 10 %, equivalent to an amount of substance concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: lanthanum,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0