Dataset Search
Sort By
Search results
34 results found
SRM 3151 Silver (Ag) Standard Solution Lot No. 160729
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of silver. A unit of SRM 3151 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of silver. The solution contains nitric acid at a mass fraction of approximately 14 %. This data is public in the Certificate of Analysis for this material.
Tags: silver,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3156 Tellurium (Te) Standard Solution Lot No. 140830
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of tellurium. A unit of SRM 3156 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of tellurium. The solution contains hydrochloric acid at a volume fraction of approximately 10 %, which is equivalent to an amount of substance concentration (molarity) of approximately 1.2 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: tellurium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3158 Thallium (Tl) Standard Solution Lot No. 993012
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of thallium. A unit of SRM 3158 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of thallium. The solution contains nitric acid at a volume fraction of approximately 10 %. This data is public in the Certificate of Analysis for this material.
Tags: thallium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3165 Vanadium (V) Standard Solution Lot No. 992706
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of vanadium. A unit of SRM 3165 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of vanadium. The solution contains nitric acid at an amount of substance concentration (molarity) of approximately 1.6 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: vanadium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Centroid Data measured between 3.6 degrees C and 25.4 degrees C for the Fab Fragment of NISTmAb
Data provided by National Institute of Standards and Technology
The spreadsheet file reported herein provides centroid data, descriptive of deuterium uptake, for the Fab Fragment of NISTmAb (PDB: 5K8A) reference material, as measured by the bottom-up hydrogen-deuterium exchange mass spectrometry (HDX-MS) method. The protein sample was incubated in deuterium-rich solutions under uniform pH and salt concentrations between 3.6 degrees C and 25.4 degrees C for seven intervals ranging (0 to 14,400) s plus a control sample that simulates a Fab Fragment immersed for infinite time in D2O.
Tags: hydrogen-deuterium exchange,hydrogen exchange,HDX-MS,interlaboratory comparison,mass spectrometry,peptide,precision,proteomics,reference material,repeatability,reproducibility,
Modified: 2024-02-22
Views: 0
NIST DART-MS Forensics Database (is-CID)
Data provided by National Institute of Standards and Technology
The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).
Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,
Modified: 2024-02-22
Views: 0
Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the Fc(gamma)RIa (CD64) Receptor
Data provided by National Institute of Standards and Technology
This database gives hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, Fc(gamma)RIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.
Tags: antibody-receptor interaction,chromatography,HDX-MS,hydrogen-deuterium exchange,glycosylation,mass spectrometry,monoclonal antibody,precision,peptide,protein,proteolysis,proteomics,receptor.,
Modified: 2024-02-22
Views: 0
NIST/EPA Gas-Phase Infrared Database JCAMP Format - SRD 35
Data provided by National Institute of Standards and Technology
This data collection contains 5,228 infrared spectra of different compounds along with chemical structures for most of them. Spectra are provided on a CD-ROM in the JCAMP-DX (Joint Committee for Atomic and Molecular Physical Data 'Data Exchange') format. Chemical structures are provided in the MOL-file format. The IR data originated from two sources, from the so-called 'EPA Vapor-Phase IR Library' and from NIST laboratories.
Tags: Joint Committee for Atomic and Molecular Physical Data,absorption spectra,chemical structures,gas phases,gases,infra red,infrared spectra,mass spectra,mass spectrometry,molecular spectroscopy,molecular vibrations,physics,spectra,spectroscopy,structural data,structures,vapor phase infrared,
Modified: 2024-02-22
Views: 0
NIST Atomic Weights and Isotopic Compositions with Relative Atomic Masses
Data provided by National Institute of Standards and Technology
The atomic weights are available for elements 1 through 118 and isotopic compositions or abundances are given when appropriate. Version 3.0.
Tags: Commission on Atomic Weights and Isotopic Abundances,International Union for Pure and Applied Chemistry,SIAM,atomic mass evaluation,Atomic Weights,Elemental Data,elements,mass spectrometry,measurements,physics,relative atomic masses,representative isotopic compositions,statistical evaluation of isotopic abundances,subcommittee for isotopic abundance,
Modified: 2024-02-22
Views: 0
NIST Synthetic Polymer MALDI Methods Database
Data provided by National Institute of Standards and Technology
This resource consists of methods for matrix-assisted laser desorption ionization (MALDI) mass spectrometry on a wide variety of synthetic polymers. The methods are taken from the peer-review scientific literature. The database covers the period from 1988, the year of Tanaka's first paper on the subject, through 2011. Each recipe comes with a literature citation and associated digital object identifier (DOI) when available. The database currently contains entries for over 1250 polymer/matrix combinations.
Tags: MALDI,mass spectrometry,polymers,
Modified: 2024-02-22
Views: 0