U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

42 results found

Dynamic compressive stress-strain curves of aluminum alloy 6061-T6 with rapid heating

Data provided by  National Institute of Standards and Technology

This dataset contains raw mechanical data (strain, stress and strain rate curvesand initial temperatures) for compression experiments performed on aluminum alloy 6061-T6using the NIST pulse-heated Kolsky Bar at strain rates between 2400 1/s and 2700 1/s and initialtemperatures from 23 °C to 527 °C and heating times ranging between 0.2 s and 3.5 s. At this time,the thermal history of the specimen during heating is not included in the dataset but this informationmay be included in a future update.

Tags: metals,mechanical properties,high heating rate,High Strain Rate,experiments,simulations,modeling,advanced manufacturing,machining,

Modified: 2024-02-22

Views: 0

NIST Inorganic Crystal Structure Database (ICSD)

Data provided by  National Institute of Standards and Technology

Materials discovery and development necessarily begins with the preparation and identification of product phase(s). Crystalline compounds can be identified by their characteristic diffraction patterns using X-rays, neutrons, and or electrons. An estimated 20,000 X-ray diffractometers and a comparable number of electron microscopes are used daily in materials research and development laboratories for this purpose.

Tags: chemical structures,crystallography,crystal structures,diffraction,disorder,electrons,identification,inorganic,neutrons,magnetic,metals,minerals,materials,Rietveld,synchrotron,twinned,x-rays,Advanced Materials,manufacturing,Safety,Security and Forensics,

Modified: 2024-02-22

Views: 0

NIST Micronutrients Measurement Quality Assurance Program Winter and Summer 2017 Comparability Studies

Data provided by  National Institute of Standards and Technology

The Micronutrients Measurement Quality Assurance Program (MMQAP) was coordinated by the Chemical Sciences Division and supported measurement technology for selected fat- and water-soluble vitamins and carotenoids in human serum. This program was initiated in 1984 by the National Cancer Institute Division of Cancer Prevention and Control to ensure the long-term reliability of the measurements made while studying the possible cancer chemoprevention roles of these compounds.

Tags: interlaboratory comparisons,Biosciences and Health,Energy,Environment and Climate,Food and Nutrition,fat-soluble vitamins,Carotenoids,Vitamin C,Human Serum,interlaboratory study,

Modified: 2024-02-22

Views: 0

Certified values of iodine in CRMs of food matrices in mg/kg units. The uncertainties are expanded uncertainties at approximately 95% confidence.

Data provided by  National Institute of Standards and Technology

A comparison of the expanded uncertainty for certified values of iodine in food matrix CRMs. The CRMS were found by searching The European Virtual Institute for Speciation Analysis (EVISA) database using the terms "Iodine" and "Certified" in the Material category. The uncertainties are expanded uncertainties at approximately 95% confidence.

Tags: food,nutrition,dietary supplements,Standard Reference materials,reference materials,SRM,RM,Food and Nutrition,

Modified: 2024-02-22

Views: 0

An approach for identification and determination of arsenic

Data provided by  National Institute of Standards and Technology

A method for the identification and determination of arsenosugars in the extract of kelp

Tags: kelp,arsenosugar,arsenic species,INAA,LC-ICP-MS,identification,IT-TOF,microwave digestion,Food and Nutrition,

Modified: 2024-02-22

Views: 0

SRM 2585 Organic Contaminants in House Dust

Data provided by  National Institute of Standards and Technology

SRM 2585 Organic Contaminants in House Dust - This Standard Reference Material (SRM) is intended for use in evaluating analytical methods for the determination of selected polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, and polybrominated diphenyl ether (PBDE) congeners in house dust and similar matrices. All of the constituents for which certified, reference, and information values are provided in SRM 2585 were naturally present in the dust material before processing.

Tags: Standard Reference Material,SRM,SRM 2585,House Dust,certified values,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 972a Vitamin D Metabolites in Frozen Human Serum

Data provided by  National Institute of Standards and Technology

SRM 972a Vitamin D Metabolites in Frozen Human Serum - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 972a,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level)

Data provided by  National Institute of Standards and Technology

SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level) - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 2973,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 3156 Tellurium (Te) Standard Solution Lot No. 140830

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of tellurium. A unit of SRM 3156 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of tellurium. The solution contains hydrochloric acid at a volume fraction of approximately 10 %, which is equivalent to an amount of substance concentration (molarity) of approximately 1.2 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: tellurium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0

SRM 3239 Isoflavones Calibration Solution

Data provided by  National Institute of Standards and Technology

SRM 3239 Isoflavones Calibration Solution - This Standard Reference Material (SRM) is intended primarily for use in calibration of instruments and techniques used for the determination of isoflavones. SRM 3239 consists of two solutions containing isoflavones at levels that reflect the mass fraction ratios found in soy products. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 3239,certified values,nutrition,dietary supplements,isoflavones,Food and Nutrition,

Modified: 2024-02-22

Views: 0