Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the Fc(gamma)RIa (CD64) Receptor

Data provided by  National Institute of Standards and Technology

This database gives hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, Fc(gamma)RIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.

Tags: antibody-receptor interaction,chromatography,HDX-MS,hydrogen-deuterium exchange,glycosylation,mass spectrometry,monoclonal antibody,precision,peptide,protein,proteolysis,proteomics,receptor.,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

Construction of a Dual-enzyme, Subzero (-30 degree C) Chromatography System and Multi-channel Precision Temperature Controller for Hydrogen-Deuterium Exchange Mass Spectrometry

Data provided by  National Institute of Standards and Technology

This tutorial provides mechanical drawings, electrical schematics, parts lists, STL files for 3D-printed parts, IGS files, and instructions for automated machining necessary for construction of a dual-protease, subzero, liquid chromatography system for hydrogen-deuterium exchange mass spectrometry. Electrical schematics for construction of a multi-zone temperature controller that regulate to ±0.1 oC are also included in this tutorial.

Tags: liquid chromatography,hydrogen-deuterium exchange,mass spectrometry,precision,peptide,protein,proteolysis,proteomics,reference material,temperature control.,

Modified: 2024-02-22

Views: 0

NIST Inorganic Crystal Structure Database (ICSD)

Data provided by  National Institute of Standards and Technology

Materials discovery and development necessarily begins with the preparation and identification of product phase(s). Crystalline compounds can be identified by their characteristic diffraction patterns using X-rays, neutrons, and or electrons. An estimated 20,000 X-ray diffractometers and a comparable number of electron microscopes are used daily in materials research and development laboratories for this purpose.

Tags: chemical structures,crystallography,crystal structures,diffraction,disorder,electrons,identification,inorganic,neutrons,magnetic,metals,minerals,materials,Rietveld,synchrotron,twinned,x-rays,Advanced Materials,manufacturing,Safety,Security and Forensics,

Modified: 2024-02-22

Views: 0

Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Centroid Data measured between 3.6 degrees C and 25.4 degrees C for the Fab Fragment of NISTmAb

Data provided by  National Institute of Standards and Technology

The spreadsheet file reported herein provides centroid data, descriptive of deuterium uptake, for the Fab Fragment of NISTmAb (PDB: 5K8A) reference material, as measured by the bottom-up hydrogen-deuterium exchange mass spectrometry (HDX-MS) method. The protein sample was incubated in deuterium-rich solutions under uniform pH and salt concentrations between 3.6 degrees C and 25.4 degrees C for seven intervals ranging (0 to 14,400) s plus a control sample that simulates a Fab Fragment immersed for infinite time in D2O.

Tags: hydrogen-deuterium exchange,hydrogen exchange,HDX-MS,interlaboratory comparison,mass spectrometry,peptide,precision,proteomics,reference material,repeatability,reproducibility,

Modified: 2024-02-22

Views: 0

SRM 2585 Organic Contaminants in House Dust

Data provided by  National Institute of Standards and Technology

SRM 2585 Organic Contaminants in House Dust - This Standard Reference Material (SRM) is intended for use in evaluating analytical methods for the determination of selected polycyclic aromatic hydrocarbons (PAHs), polychlorinated biphenyl (PCB) congeners, chlorinated pesticides, and polybrominated diphenyl ether (PBDE) congeners in house dust and similar matrices. All of the constituents for which certified, reference, and information values are provided in SRM 2585 were naturally present in the dust material before processing.

Tags: Standard Reference Material,SRM,SRM 2585,House Dust,certified values,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 972a Vitamin D Metabolites in Frozen Human Serum

Data provided by  National Institute of Standards and Technology

SRM 972a Vitamin D Metabolites in Frozen Human Serum - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 972a,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level)

Data provided by  National Institute of Standards and Technology

SRM 2973 Vitamin D Metabolites in Frozen Human Serum (High Level) - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 2973,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 3156 Tellurium (Te) Standard Solution Lot No. 140830

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of tellurium. A unit of SRM 3156 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of tellurium. The solution contains hydrochloric acid at a volume fraction of approximately 10 %, which is equivalent to an amount of substance concentration (molarity) of approximately 1.2 mol/L. This data is public in the Certificate of Analysis for this material.

Tags: tellurium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,

Modified: 2024-02-22

Views: 0