Dataset Search
Sort By
Search results
66 results found
Asynchronous AM Bench 2022 Challenge Data: Real-time, simultaneous absorptance and high-speed Xray imaging
Data provided by National Institute of Standards and Technology
The absolute laser absorption was measured simultaneously with X-ray imaging during laser melting of Ti-6Al-4V solid metal. The data included here are the time-resolved absolute absorbed power and the Xray images acquired at the same time, along with timing data for synchronization. Also included is information about the experimental configuration including applied laser power, laser beam spatial profile, and the experimental setup. A text document is included that describes all files.
Tags: additive manufacturing,Laser Welding,
Modified: 2024-02-22
Views: 0
NIST Inorganic Crystal Structure Database (ICSD)
Data provided by National Institute of Standards and Technology
Materials discovery and development necessarily begins with the preparation and identification of product phase(s). Crystalline compounds can be identified by their characteristic diffraction patterns using X-rays, neutrons, and or electrons. An estimated 20,000 X-ray diffractometers and a comparable number of electron microscopes are used daily in materials research and development laboratories for this purpose.
Tags: chemical structures,crystallography,crystal structures,diffraction,disorder,electrons,identification,inorganic,neutrons,magnetic,metals,minerals,materials,Rietveld,synchrotron,twinned,x-rays,Advanced Materials,manufacturing,Safety,Security and Forensics,
Modified: 2024-02-22
Views: 0
Construction of a Dual-enzyme, Subzero (-30 degree C) Chromatography System and Multi-channel Precision Temperature Controller for Hydrogen-Deuterium Exchange Mass Spectrometry
Data provided by National Institute of Standards and Technology
This tutorial provides mechanical drawings, electrical schematics, parts lists, STL files for 3D-printed parts, IGS files, and instructions for automated machining necessary for construction of a dual-protease, subzero, liquid chromatography system for hydrogen-deuterium exchange mass spectrometry. Electrical schematics for construction of a multi-zone temperature controller that regulate to ±0.1 oC are also included in this tutorial.
Tags: liquid chromatography,hydrogen-deuterium exchange,mass spectrometry,precision,peptide,protein,proteolysis,proteomics,reference material,temperature control.,
Modified: 2024-02-22
Views: 0
Calculation Sheet for Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed
Data provided by National Institute of Standards and Technology
This dataset includes a Microsoft Excel spreadsheet (*.xlsx file) provided as supplemental material for the NIST Technical Note (TN-2099) publication titled "Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed". The file contains two tabs, titled "Pre-Compensation" and "Post-Compensation", which provides example measurement data and calculations pertaining to the calibration procedures described in the publication.
Tags: additive manufacturing,calibration,Galvanometer,Laser Powder Bed Fusion,
Modified: 2024-02-22
Views: 0
Supplementary Data for the paper "Three-Dimensional Particle Shape Analysis Using X-ray Computed Tomography: Experimental Procedure and Analysis Algorithms for Metal Powders" by E.J. Garboczi and N. Hrabe
Data provided by National Institute of Standards and Technology
Supplementary Data for the paper "Three-Dimensional Particle Shape Analysis Using X-ray Computed Tomography: Experimental Procedure and Analysis Algorithms for Metal Powders" by E.J. Garboczi and N. Hrabe. Contains all the data and programs described in this paper to generate the results discussed in the paper. Also contains all the results that are generated by the data and programs, with which the user can compare to check their results.
Tags: additive manufacturing,metal powder,Laser Powder Bed Fusion,particle shape analysis,X-ray computed tomography. spherical harmonics,image analysis,powder analysis,powder particles,titanium alloy,Ti64,
Modified: 2024-02-22
Views: 0
Development of a Tool to Determine the Variability of Consensus Mass Spectra Supporting Data
Data provided by National Institute of Standards and Technology
Supporting datasets and algorithms (R-based) for the manuscript entitled "Development of a Tool to Determine the Variability of Consensus Mass Spectra", including an R Markdown script to reproduce the manuscript's figures.
Tags: mass spectrometry,uncertainty analysis,per- and polyfluoroalkyl substances,PFAS,reference mass spectrum,
Modified: 2024-02-22
Views: 0
SRM 3104a Barium (Ba) Standard Solution Lot No. 140909
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of barium. A unit of SRM 3104a consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of barium. The solution contains nitric acid at a volume fraction of approximately 1 %, which is equivalent to a concentration (molarity) of approximately 0.16 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: barium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3110 Cerium (Ce) Standard Solution Lot No. 160830
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of cerium. A unit of SRM 3110 consists of five 10 mL sealed borosilicate glass ampoules of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of cerium. The solution contains nitric acid at a mass fraction of approximately 16 %. This data is public in the Certificate of Analysis for this material.
Tags: cerium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3120a Germanium (Ge) Standard Solution Lot No. 080429
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of germanium. A unit of SRM 3120a consists of 50 mL of a single element solution in a high density polyethylene bottle sealed in an aluminized bag. The solution was prepared gravimetrically to contain a known mass fraction of germanium. The solution contains nitric acid at a concentration of approximately 1.6 mol/L and hydrofluoric acid at a concentration of approximately 0.6 mol/L. This data is public in the Certificate of Analysis for this material.
Tags: germanium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0
SRM 3122 Hafnium (Hf) Standard Solution Lot No. 151120
Data provided by National Institute of Standards and Technology
This Standard Reference Material (SRM) is intended for use as a primary calibration standard for the quantitative determination of hafnium. A unit of SRM 3122 consists of 50 mL of an acidified aqueous solution prepared gravimetrically to contain a known mass fraction of hafnium in a high density polyethylene bottle sealed in an aluminized bag. The solution contains approximately 8 % nitric acid (volume fraction) and approximately 1 % hydrofluoric acid (volume fraction), equivalent to amount of substance concentrations (molarities) of 1.3 mol/L and 0.3 mol/L, respectively.
Tags: hafnium,pure materials,cations,metals,single element solutions,spectrometry,Advanced Materials,
Modified: 2024-02-22
Views: 0