SRM 999c Potassium Chloride (High-Purity Chemical)

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as an analytical standard of known potassium (K) and chloride (Cl-) content. This lot of potassium chloride (KCl) was prepared to ensure a material of high purity and homogeneity and has been assayed after drying at 500 °C. A unit of SRM 999c consists of a single glass bottle containing 30 g of the material. This data is public in the Certificate of Analysis for this material.

Tags: high purity chemical,clinical,Standard Reference Material,SRM,potassium chloride,potassium,chloride,Food and Nutrition,

Modified: 2024-02-22

Views: 0

SRM 1721 Southern Oceanic Air (Ambient Nominal Amount-of-Substance Fraction: Carbon Dioxide, Methane, Nitrous Oxide)

Data provided by  National Institute of Standards and Technology

Standard Reference Material-1721: Southern Oceanic Air. Ambient Nominal Amount of Substance Fraction for Carbon Dioxide, Methane & Nitrous Oxide. This Standard Reference Material (SRM) is a primary gas mixture for which the amount-of-substance fraction, expressed as concentration, may be related to secondary working standards. This SRM is intended for the calibration of instruments used for ambient carbon dioxide (CO2), methane (CH4) and nitrous oxide (N2O) determinations and for other applications. This data is public in the Certificate of Analysis for this material.

Tags: SRM,Standard Reference Material,Southern Oceanic Air,carbon dioxide,methane,Nitrous Oxide,CO2,CH4,N2O,amount of substance,Energy,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 918c Potassium Chloride General and Ion Activity Standard

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as an analytical standard of known purity. It is intended primarily for use in the calibration and standardization of procedures for potassium (K) and chloride (Cl-) determinations employed in clinical analysis, including those using ion-selective electrodes, and for routine critical evaluation of the daily working standards used in these procedures. This lot of potassium chloride (KCl) was prepared to ensure a material of high purity and homogeneity and has been assayed after heating at 110 degrees C to 120 degrees C.

Tags: SRM,Standard Reference Material,potassium chloride,

Modified: 2024-02-22

Views: 0

Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Centroid Data measured between 3.6 degrees C and 25.4 degrees C for the Fab Fragment of NISTmAb

Data provided by  National Institute of Standards and Technology

The spreadsheet file reported herein provides centroid data, descriptive of deuterium uptake, for the Fab Fragment of NISTmAb (PDB: 5K8A) reference material, as measured by the bottom-up hydrogen-deuterium exchange mass spectrometry (HDX-MS) method. The protein sample was incubated in deuterium-rich solutions under uniform pH and salt concentrations between 3.6 degrees C and 25.4 degrees C for seven intervals ranging (0 to 14,400) s plus a control sample that simulates a Fab Fragment immersed for infinite time in D2O.

Tags: hydrogen-deuterium exchange,hydrogen exchange,HDX-MS,interlaboratory comparison,mass spectrometry,peptide,precision,proteomics,reference material,repeatability,reproducibility,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the Fc(gamma)RIa (CD64) Receptor

Data provided by  National Institute of Standards and Technology

This database gives hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, Fc(gamma)RIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.

Tags: antibody-receptor interaction,chromatography,HDX-MS,hydrogen-deuterium exchange,glycosylation,mass spectrometry,monoclonal antibody,precision,peptide,protein,proteolysis,proteomics,receptor.,

Modified: 2024-02-22

Views: 0

NIST/EPA Gas-Phase Infrared Database JCAMP Format - SRD 35

Data provided by  National Institute of Standards and Technology

This data collection contains 5,228 infrared spectra of different compounds along with chemical structures for most of them. Spectra are provided on a CD-ROM in the JCAMP-DX (Joint Committee for Atomic and Molecular Physical Data 'Data Exchange') format. Chemical structures are provided in the MOL-file format. The IR data originated from two sources, from the so-called 'EPA Vapor-Phase IR Library' and from NIST laboratories.

Tags: Joint Committee for Atomic and Molecular Physical Data,absorption spectra,chemical structures,gas phases,gases,infra red,infrared spectra,mass spectra,mass spectrometry,molecular spectroscopy,molecular vibrations,physics,spectra,spectroscopy,structural data,structures,vapor phase infrared,

Modified: 2024-02-22

Views: 0

NIST Atomic Weights and Isotopic Compositions with Relative Atomic Masses

Data provided by  National Institute of Standards and Technology

The atomic weights are available for elements 1 through 118 and isotopic compositions or abundances are given when appropriate. Version 3.0.

Tags: Commission on Atomic Weights and Isotopic Abundances,International Union for Pure and Applied Chemistry,SIAM,atomic mass evaluation,Atomic Weights,Elemental Data,elements,mass spectrometry,measurements,physics,relative atomic masses,representative isotopic compositions,statistical evaluation of isotopic abundances,subcommittee for isotopic abundance,

Modified: 2024-02-22

Views: 0

NIST MEMS Calculator - SRD 166

Data provided by  National Institute of Standards and Technology

This MEMS Calculator determines the following thin film properties from data taken with an optical interferometer or comparable instrument: a) residual strain from fixed-fixed beams, b) strain gradient from cantilevers, c) step heights or thicknesses from step-height test structures, and d) in-plane lengths or deflections. Then, residual stress and stress gradient calculations can be made after an optical vibrometer or comparable instrument is used to obtain Young's modulus from resonating cantilevers or fixed-fixed beams.

Tags: ASTM,MEMS 5 in 1,MEMS Calculators,Micro Electro Mechanical Systems,Semiconductor Equipment and Materials International,Standard Reference Material,Young's modulus measurements,cantilevers,data analysis sheets,fixed-fixed beams,height measurements,interferometries,length measurements,residual strains,residual stresses,steps,strain gradients,stress gradients,test structures,thick,vibrometries,

Modified: 2024-02-22

Views: 0

NIST Synthetic Polymer MALDI Methods Database

Data provided by  National Institute of Standards and Technology

This resource consists of methods for matrix-assisted laser desorption ionization (MALDI) mass spectrometry on a wide variety of synthetic polymers. The methods are taken from the peer-review scientific literature. The database covers the period from 1988, the year of Tanaka's first paper on the subject, through 2011. Each recipe comes with a literature citation and associated digital object identifier (DOI) when available. The database currently contains entries for over 1250 polymer/matrix combinations.

Tags: MALDI,mass spectrometry,polymers,

Modified: 2024-02-22