SRM 3532 Calcium-Containing Solid Oral Dosage Form

Data provided by  National Institute of Standards and Technology

SRM 3532 Calcium-Containing Solid Oral Dosage Form - This Standard Reference Material (SRM) is intended primarily for validation of methods for determining cholecalciferol (vitamin D3) and elements in a calcium dietary supplement and similar materials. This SRM can also be used for quality assurance when assigning values to in-house reference materials. A unit of SRM 3532 consists of five packets, each containing approximately 10 g of material. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference materials,SRM,SRM 3532,calcium supplement,food,nutrition,dietary supplements,certified value,reference value,Food and Nutrition,

Modified: 2024-02-22

Views: 0

SRM 3949 Folate Vitamers in Frozen Human Serum

Data provided by  National Institute of Standards and Technology

Standard Reference Material 3949 Folate Vitamers in Frozen Human Serum

Tags: Standard Reference Material,SRM,SRM 3949,Frozen Human Serum,certified values,reference values,folate vitamers,folates,folic acid,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 909c Frozen Human Serum

Data provided by  National Institute of Standards and Technology

Standard Reference Material 909c Frozen Human Serum - This Standard Reference Material (SRM) is intended primarily for use in validating analytical methods for the determination of specified constituents in human serum. This SRM can also be used for quality assurance when assigning values to in house control materials. A unit of SRM 909c consists of three vials, each containing 2 mL of frozen human serum. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 909c,Frozen Human Serum,certified values,reference values,metabolites,electrolytes,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 972a Vitamin D Metabolites in Frozen Human Serum

Data provided by  National Institute of Standards and Technology

SRM 972a Vitamin D Metabolites in Frozen Human Serum - This Standard Reference Material (SRM) is intended for use as an accuracy control in the critical evaluation of methods for determining the amount-of-substance concentration of vitamin D metabolites in human serum. This SRM can also be used as a quality assurance tool for assigning values to in-house control materials for these constituents. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 972a,Frozen Human Serum,certified values,reference values,Vitamin D Metabolites,25-hydroxyvitamin D3,25-hydroxyvitamin D2,3-epi-25-hydroxyvitamin D3,24R,25-dihydroxyvitamin D3,Biosciences and Health,

Modified: 2024-02-22

Views: 0

SRM 999c Potassium Chloride (High-Purity Chemical)

Data provided by  National Institute of Standards and Technology

This Standard Reference Material (SRM) is intended for use as an analytical standard of known potassium (K) and chloride (Cl-) content. This lot of potassium chloride (KCl) was prepared to ensure a material of high purity and homogeneity and has been assayed after drying at 500 °C. A unit of SRM 999c consists of a single glass bottle containing 30 g of the material. This data is public in the Certificate of Analysis for this material.

Tags: high purity chemical,clinical,Standard Reference Material,SRM,potassium chloride,potassium,chloride,Food and Nutrition,

Modified: 2024-02-22

Views: 0

Certified values of iodine in CRMs of food matrices in mg/kg units. The uncertainties are expanded uncertainties at approximately 95% confidence.

Data provided by  National Institute of Standards and Technology

A comparison of the expanded uncertainty for certified values of iodine in food matrix CRMs. The CRMS were found by searching The European Virtual Institute for Speciation Analysis (EVISA) database using the terms "Iodine" and "Certified" in the Material category. The uncertainties are expanded uncertainties at approximately 95% confidence.

Tags: food,nutrition,dietary supplements,Standard Reference materials,reference materials,SRM,RM,Food and Nutrition,

Modified: 2024-02-22

Views: 0

Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Centroid Data measured between 3.6 degrees C and 25.4 degrees C for the Fab Fragment of NISTmAb

Data provided by  National Institute of Standards and Technology

The spreadsheet file reported herein provides centroid data, descriptive of deuterium uptake, for the Fab Fragment of NISTmAb (PDB: 5K8A) reference material, as measured by the bottom-up hydrogen-deuterium exchange mass spectrometry (HDX-MS) method. The protein sample was incubated in deuterium-rich solutions under uniform pH and salt concentrations between 3.6 degrees C and 25.4 degrees C for seven intervals ranging (0 to 14,400) s plus a control sample that simulates a Fab Fragment immersed for infinite time in D2O.

Tags: hydrogen-deuterium exchange,hydrogen exchange,HDX-MS,interlaboratory comparison,mass spectrometry,peptide,precision,proteomics,reference material,repeatability,reproducibility,

Modified: 2024-02-22

Views: 0

NIST Micronutrients Measurement Quality Assurance Program Winter and Summer 2017 Comparability Studies

Data provided by  National Institute of Standards and Technology

The Micronutrients Measurement Quality Assurance Program (MMQAP) was coordinated by the Chemical Sciences Division and supported measurement technology for selected fat- and water-soluble vitamins and carotenoids in human serum. This program was initiated in 1984 by the National Cancer Institute Division of Cancer Prevention and Control to ensure the long-term reliability of the measurements made while studying the possible cancer chemoprevention roles of these compounds.

Tags: interlaboratory comparisons,Biosciences and Health,Energy,Environment and Climate,Food and Nutrition,fat-soluble vitamins,Carotenoids,Vitamin C,Human Serum,interlaboratory study,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the Fc(gamma)RIa (CD64) Receptor

Data provided by  National Institute of Standards and Technology

This database gives hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, Fc(gamma)RIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.

Tags: antibody-receptor interaction,chromatography,HDX-MS,hydrogen-deuterium exchange,glycosylation,mass spectrometry,monoclonal antibody,precision,peptide,protein,proteolysis,proteomics,receptor.,

Modified: 2024-02-22

Views: 0