U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

42 results found

Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Centroid Data measured between 3.6 degrees C and 25.4 degrees C for the Fab Fragment of NISTmAb

Data provided by  National Institute of Standards and Technology

The spreadsheet file reported herein provides centroid data, descriptive of deuterium uptake, for the Fab Fragment of NISTmAb (PDB: 5K8A) reference material, as measured by the bottom-up hydrogen-deuterium exchange mass spectrometry (HDX-MS) method. The protein sample was incubated in deuterium-rich solutions under uniform pH and salt concentrations between 3.6 degrees C and 25.4 degrees C for seven intervals ranging (0 to 14,400) s plus a control sample that simulates a Fab Fragment immersed for infinite time in D2O.

Tags: hydrogen-deuterium exchange,hydrogen exchange,HDX-MS,interlaboratory comparison,mass spectrometry,peptide,precision,proteomics,reference material,repeatability,reproducibility,

Modified: 2024-02-22

Views: 0

Construction of a Dual-enzyme, Subzero (-30 degree C) Chromatography System and Multi-channel Precision Temperature Controller for Hydrogen-Deuterium Exchange Mass Spectrometry

Data provided by  National Institute of Standards and Technology

This tutorial provides mechanical drawings, electrical schematics, parts lists, STL files for 3D-printed parts, IGS files, and instructions for automated machining necessary for construction of a dual-protease, subzero, liquid chromatography system for hydrogen-deuterium exchange mass spectrometry. Electrical schematics for construction of a multi-zone temperature controller that regulate to ±0.1 oC are also included in this tutorial.

Tags: liquid chromatography,hydrogen-deuterium exchange,mass spectrometry,precision,peptide,protein,proteolysis,proteomics,reference material,temperature control.,

Modified: 2024-02-22

Views: 0

pyLLE: a Fast and User Friendly Lugiato-Lefever Equation Solver

Data provided by  National Institute of Standards and Technology

We present the development of pyLLE, a freely accessible Lugiato-Lefever equation solver programmed in Python and Julia and optimized for the simulation of microresonator frequency combs. Examples illustrating its operation and performance are presented.

Tags: photonics,optics,frequency combs,python,julia,

Modified: 2024-02-22

Views: 0

Optimal Bayesian Experimental Design

Data provided by  National Institute of Standards and Technology

Python module "optbayesexpt" uses optimal Bayesian experimental design methods to control measurement settings in order to efficiently determine model parameters. Given a parametric model - analogous to a fitting function - Bayesian inference uses each measurement "data point" to refine model parameters. Using this information, the software suggests measurement settings that are likely to efficiently reduce uncertainties. A TCP socket interface allows the software to be used from experimental control software written in other programming languages.

Tags: GitHub pages template,experimental design,Bayesian,optbayesexpt,python,measurement,

Modified: 2024-02-22

Views: 0

SEDCORR: An Algorithm for Correcting Systematic Energy Deficits in the Atom Probe Mass Spectra

Data provided by  National Institute of Standards and Technology

SEDCORR is an open-source Python module designed to correct for the systematic energy deficits in atom probe mass spectra of electrically insulating samples. The assumption of the algorithm is that the mass spectrum for a dataset is conserved throughout the dataset and that any changes to the peak positions arise from an unknown slowly-fluctuating accelerating voltage. For computational speed, the unknown accelerating voltage is determined using a template matching FFT-based cross correlation method.

Tags: atom probe microscopy,insulator,mass spectra,energy deficit correction,python,FFT,

Modified: 2024-02-22

Views: 0

Optimal Bayesian Experimental Design Version 1.0.1

Data provided by  National Institute of Standards and Technology

Python module 'optbayesexpt' uses optimal Bayesian experimental design methods to control measurement settings in order to efficiently determine model parameters. Given an parametric model - analogous to a fitting function - Bayesian inference uses each measurement 'data point' to refine model parameters. Using this information, the software suggests measurement settings that are likely to efficiently reduce uncertainties. A TCP socket interface allows the software to be used from experimental control software written in other programming languages.

Tags: GitHub pages template,experimental design,Bayesian,optbayesexpt,python,measurement,

Modified: 2024-02-22

Views: 0

pySCATMECH: A Python interface to the SCATMECH C++ library of polarized light scattering codes

Data provided by  National Institute of Standards and Technology

SCATMECH is a library of object-oriented C++ computer codes originally developed for disseminating models for polarized light scattering from surfaces and aerosols and for diffraction from gratings. The pySCATMECH package has been developed as an interface to the SCATMECH library, simplifying use of the codes and allowing for more rapid development of software for these applications.

Tags: aerosol,bidirectional reflectance,BRDF,diffuse,gratings,Mie scattering,modeling,Mueller matrix,polarization,python,roughness,scatter,surface,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

NIST DART-MS Forensics Database (is-CID)

Data provided by  National Institute of Standards and Technology

The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).

Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,

Modified: 2024-02-22

Views: 0

Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the Fc(gamma)RIa (CD64) Receptor

Data provided by  National Institute of Standards and Technology

This database gives hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, Fc(gamma)RIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.

Tags: antibody-receptor interaction,chromatography,HDX-MS,hydrogen-deuterium exchange,glycosylation,mass spectrometry,monoclonal antibody,precision,peptide,protein,proteolysis,proteomics,receptor.,

Modified: 2024-02-22

Views: 0