61 results found

Comparison of primary laser spectroscopy and mass spectrometry methods for measuring mass concentration of gaseous elemental mercury

Data provided by  National Institute of Standards and Technology

Data for mass concentration analysis and spectral analysis for the paper titled, "Comparison of primary laser spectroscopy and mass spectrometry methods for measuring mass concentration of gaseous elemental mercury"

Tags: mercury,laser absorption spectroscopy,Standard Generator,SI traceability,ID-CV-ICP-MS,primary measurement method,Environment and Climate,

Modified: 2024-02-22

Views: 0

Optical scattering measurements and simulation data for one-dimensional (1-D) patterned periodic sub-wavelength features

Data provided by  National Institute of Standards and Technology

This data set consists of both measured and simulated optical intensities scattered off periodic line arrays, with simulations based upon an average geometric model for these lines. These data were generated in order to determine the average feature sizes based on optical scattering, which is an inverse problem for which solutions to the forward problem are calculated using electromagnetic simulations after a parameterization of the feature geometry.

Tags: electromagnetic simulations,simulations,experimental,angle-resolved scattering,scattering,gratings,patterned semiconductors,semiconductors,scatterfield microscopy,bright-field microscopy,microscopy,inverse problems,machine learning,

Modified: 2024-02-22

Views: 0

SRM 3672 Organic Contaminants in Smokers' Urine (Frozen)

Data provided by  National Institute of Standards and Technology

SRM 3672 Organic Contaminants in Smokers' Urine (Frozen) - This Standard Reference Material (SRM) is intended for use in evaluating analytical methods for the determination of selected hydroxylated polycyclic aromatic hydrocarbons (hydroxylated PAHs) and phthalate, phenol, and volatile organic compound (VOC) metabolites in urine. All of the constituents for which certified and reference values are provided are naturally present in the urine. This data is public in the Certificate of Analysis for this material.

Tags: reference materials,hydroxylated PAHs,phthalate metabolites,phenol metabolites,VOC metabolites,drugs,health markers,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen)

Data provided by  National Institute of Standards and Technology

SRM 3673 Organic Contaminants in Non-Smokers' Urine (Frozen) - This Standard Reference Material (SRM) is intended for use in evaluating analytical methods for the determination of selected hydroxylated polycyclic aromatic hydrocarbons (hydroxylated PAHs) and phthalate, phenol, and volatile organic compound (VOC) metabolites in urine. All of the constituents for which certified and reference values are provided are naturally present in the urine. This data is public in the Certificate of Analysis for this material.

Tags: reference materials,hydroxylated PAHs,phthalate metabolites,phenol metabolites,VOC metabolites,drugs,health markers,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 695 Trace Elements in Multi-Nutrient Fertilizer

Data provided by  National Institute of Standards and Technology

Standard Reference Material 695 Trace Elements in Multi-Nutrient Fertilizer - This Standard Reference Material (SRM) is intended primarily for use in the evaluation of techniques employed in the analysis of multi-nutrient fertilizer materials and materials of a similar matrix. A unit of SRM 695 consists of approximately 70 g of jet-milled fertilizer. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,fertilizer,trace elements,Environment and Climate,

Modified: 2024-02-22

Views: 0

SRM 1721 Southern Oceanic Air (Ambient Nominal Amount-of-Substance Fraction: Carbon Dioxide, Methane, Nitrous Oxide)

Data provided by  National Institute of Standards and Technology

Standard Reference Material-1721: Southern Oceanic Air. Ambient Nominal Amount of Substance Fraction for Carbon Dioxide, Methane & Nitrous Oxide. This Standard Reference Material (SRM) is a primary gas mixture for which the amount-of-substance fraction, expressed as concentration, may be related to secondary working standards. This SRM is intended for the calibration of instruments used for ambient carbon dioxide (CO2), methane (CH4) and nitrous oxide (N2O) determinations and for other applications. This data is public in the Certificate of Analysis for this material.

Tags: SRM,Standard Reference Material,Southern Oceanic Air,carbon dioxide,methane,Nitrous Oxide,CO2,CH4,N2O,amount of substance,Energy,Environment and Climate,

Modified: 2024-02-22

Views: 0

FIB SEM image data set of Caenorhabditis elegans exposed to 60 nm Au nanoparticles

Data provided by  National Institute of Standards and Technology

This folder contains image data sets from 14 separate serial sectioning sessions. The entire data folder consists of 1379 8 bit tif images and is 47.3 GB in size. Serial sectioning was performed using FEI Helios 660 NanoLab focused ion beam scanning electron microscope (FIB SEM) and Auto Slice and View G3 software. The sample was a heavy metal stained and resin embedded Caenorhabditis elegans (C. elegans) that were exposed to 60 nm Au nanoparticles. Detailed descriptions of the worm preparation and resin block processing are described in Johnson, M.E. et al. (ACS Nano, 2016).

Tags: Advanced Materials,Biosciences and Health,Environment and Climate,manufacturing,Visualization Research,Nanotechnology,

Modified: 2024-02-22

Views: 0

QFlow 2.0: Quantum dot data for machine learning

Data provided by  National Institute of Standards and Technology

Using a modified Thomas-Fermi approximation, we model a reference semiconductor system comprising a quasi-1D nanowire with a series of five depletion gates whose voltages determine the number of quantum dots (QDs), the charges on each of the QDs, as well as the conductance through the wire. The original dataset, QFlow lite, consists of 1 001 idealized simulated measurements with gate configurations sampling over different realizations of the same type of device.

Tags: machine learning,quantum dots,simulated data,

Modified: 2024-02-22

Views: 0

Nestor: a toolkit for quantifying tacit maintenance knowledge, for investigatory analysis in smart manufacturing

Data provided by  National Institute of Standards and Technology

There is often a large amount of maintenance data already available for use in Smart Manufacturing systems, but in a currently-unusable form: service tickets and maintenance work orders (MWOs). Nestor is a toolkit for using Natural Language Processing (NLP) with efficient user-interaction to perform structured data extraction with minimal annotation time-cost.

Tags: information,communication,maintenance,tribal knowledge,event sequences,training,machine learning,data cleaning,prognostics,diagnostics,visualization,decision guidance,CMMS,scheduling,investigations,nestor,smart manufacturing,manufacturing operations,manufacturing performance,

Modified: 2024-02-22

Views: 0

NIST Micronutrients Measurement Quality Assurance Program Winter and Summer 2017 Comparability Studies

Data provided by  National Institute of Standards and Technology

The Micronutrients Measurement Quality Assurance Program (MMQAP) was coordinated by the Chemical Sciences Division and supported measurement technology for selected fat- and water-soluble vitamins and carotenoids in human serum. This program was initiated in 1984 by the National Cancer Institute Division of Cancer Prevention and Control to ensure the long-term reliability of the measurements made while studying the possible cancer chemoprevention roles of these compounds.

Tags: interlaboratory comparisons,Biosciences and Health,Energy,Environment and Climate,Food and Nutrition,fat-soluble vitamins,Carotenoids,Vitamin C,Human Serum,interlaboratory study,

Modified: 2024-02-22

Views: 0