Dataset Search
Sort By
Search results
59 results found
Variation of Surface Topography in Laser Powder Bed Fusion Additive Manufacturing of Nickel Super Alloy 625
Data provided by National Institute of Standards and Technology
This dataset provides surface height data from nickel super alloy 625 experiment samples built through laser powder bed fusion additive manufacturing. The experiment methodically varied part position and orientation relative to the build plate and recoater blade and details of the experiment and dataset are available in a Journal of Research at NIST article.
Tags: additive manufacturing,focus variation,IN625,Laser Powder Bed Fusion,nickel super alloy 625,surface texture,surface topography,
Modified: 2024-02-22
Views: 0
In situ thermography of the metal bridge structures fabricated for the 2018 Additive Manufacturing Benchmark Test Series (AM-Bench 2018)
Data provided by National Institute of Standards and Technology
These measurements were performed as part of the 2018 Additive Manufacturing Benchmark Test Series (AM-Bench). This dataset and the associated experiments are part of a continuing series of controlled benchmark tests, in conjunction with a conference series, with two initial goals, 1) to allow modelers of Additive Manufacturing processes to test their simulations against rigorous, highly controlled additive manufacturing benchmark test data, and 2) to encourage additive manufacturing practitioners to develop novel mitigation strategies for challenging build scenarios.
Tags: additive manufacturing,benchmark tests,AMBench,AMBench 2018,powder bed fusion,nickel super alloy 625,IN625,thermography,cooling rate,temperature,
Modified: 2024-02-22
Views: 0
Hydrogen-Deuterium Exchange Mass Spectrometry (HDX-MS) Centroid Data measured between 3.6 degrees C and 25.4 degrees C for the Fab Fragment of NISTmAb
Data provided by National Institute of Standards and Technology
The spreadsheet file reported herein provides centroid data, descriptive of deuterium uptake, for the Fab Fragment of NISTmAb (PDB: 5K8A) reference material, as measured by the bottom-up hydrogen-deuterium exchange mass spectrometry (HDX-MS) method. The protein sample was incubated in deuterium-rich solutions under uniform pH and salt concentrations between 3.6 degrees C and 25.4 degrees C for seven intervals ranging (0 to 14,400) s plus a control sample that simulates a Fab Fragment immersed for infinite time in D2O.
Tags: hydrogen-deuterium exchange,hydrogen exchange,HDX-MS,interlaboratory comparison,mass spectrometry,peptide,precision,proteomics,reference material,repeatability,reproducibility,
Modified: 2024-02-22
Views: 0
Construction of a Dual-enzyme, Subzero (-30 degree C) Chromatography System and Multi-channel Precision Temperature Controller for Hydrogen-Deuterium Exchange Mass Spectrometry
Data provided by National Institute of Standards and Technology
This tutorial provides mechanical drawings, electrical schematics, parts lists, STL files for 3D-printed parts, IGS files, and instructions for automated machining necessary for construction of a dual-protease, subzero, liquid chromatography system for hydrogen-deuterium exchange mass spectrometry. Electrical schematics for construction of a multi-zone temperature controller that regulate to ±0.1 oC are also included in this tutorial.
Tags: liquid chromatography,hydrogen-deuterium exchange,mass spectrometry,precision,peptide,protein,proteolysis,proteomics,reference material,temperature control.,
Modified: 2024-02-22
Views: 0
Supplementary Data for the paper "Three-Dimensional Particle Shape Analysis Using X-ray Computed Tomography: Experimental Procedure and Analysis Algorithms for Metal Powders" by E.J. Garboczi and N. Hrabe
Data provided by National Institute of Standards and Technology
Supplementary Data for the paper "Three-Dimensional Particle Shape Analysis Using X-ray Computed Tomography: Experimental Procedure and Analysis Algorithms for Metal Powders" by E.J. Garboczi and N. Hrabe. Contains all the data and programs described in this paper to generate the results discussed in the paper. Also contains all the results that are generated by the data and programs, with which the user can compare to check their results.
Tags: additive manufacturing,metal powder,Laser Powder Bed Fusion,particle shape analysis,X-ray computed tomography. spherical harmonics,image analysis,powder analysis,powder particles,titanium alloy,Ti64,
Modified: 2024-02-22
Views: 0
Calculation Sheet for Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed
Data provided by National Institute of Standards and Technology
This dataset includes a Microsoft Excel spreadsheet (*.xlsx file) provided as supplemental material for the NIST Technical Note (TN-2099) publication titled "Quasi-Static Position Calibration of the Galvanometer Scanner on the Additive Manufacturing Metrology Testbed". The file contains two tabs, titled "Pre-Compensation" and "Post-Compensation", which provides example measurement data and calculations pertaining to the calibration procedures described in the publication.
Tags: additive manufacturing,calibration,Galvanometer,Laser Powder Bed Fusion,
Modified: 2024-02-22
Views: 0
NIST DART-MS Forensics Database (is-CID)
Data provided by National Institute of Standards and Technology
The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).
Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,
Modified: 2024-02-22
Views: 0
NIST DART-MS Forensics Database (is-CID)
Data provided by National Institute of Standards and Technology
The NIST DART-MS Forensics Database is an evaluated collection of in-source collisionally-induced dissociation (is-CID) mass spectra of compounds of interest to the forensics community (e.g. seized drugs, cutting agents, etc.). The is-CID mass spectra were collected using Direct Analysis in Real-Time (DART) Mass Spectrometry (MS), either by NIST scientists or by contributing agencies noted per compound. The database is provided as a general-purpose structure data file (.SDF).
Tags: Standard reference data,mass spectra,Ion Fragmentation,mass spectrometry,NIST Mass Spectral Libraries,Chemical Identification,Biosciences and Health,Security and Forensics,
Modified: 2024-02-22
Views: 0
Additively manufactured CoCr lattice artifact -- 3D design
Data provided by National Institute of Standards and Technology
SolidWorks Part file (CAD file) for a CoCr "lattice" structure additively manufactured in a laser bed powder fusion (LPBF) system at NIST.
Tags: additive manufacturing,CoCr,lattice structure,CAD drawing,
Modified: 2024-02-22
Views: 0
Dataset from HDX-MS Studies of IgG1 Glycoforms and Their Interactions with the Fc(gamma)RIa (CD64) Receptor
Data provided by National Institute of Standards and Technology
This database gives hydrogen-deuterium exchange mass spectrometry (HDX-MS) data from measurements of three purified IgG1 glycoform samples, predominantly G0F, G2F, and SAF, in isolation and in complexation with the high-affinity receptor, Fc(gamma)RIa (CD64). The IgG1 antibody used in this study, aIL8hFc, is a murine-human chimeric IgG1, which inhibits IL-8 binding to human neutrophils.
Tags: antibody-receptor interaction,chromatography,HDX-MS,hydrogen-deuterium exchange,glycosylation,mass spectrometry,monoclonal antibody,precision,peptide,protein,proteolysis,proteomics,receptor.,
Modified: 2024-02-22
Views: 0