U.S. flag

An official website of the United States government

Dot gov

Official websites use .gov
A .gov website belongs to an official government organization in the United States.

Https

Secure .gov websites use HTTPS
A lock () or https:// means you’ve safely connected to the .gov website. Share sensitive information only on official, secure websites.

Breadcrumb

  1. Home

Dataset Search

Search results

32 results found

SRM 2387 Peanut Butter

Data provided by  National Institute of Standards and Technology

SRM 2387 Peanut Butter - This Standard Reference Material (SRM) is intended primarily for use in validating methods for determining proximates, fatty acids, calories, vitamins, elements, amino acids, aflatoxins, and acrylamide in peanut butter and similar matrices. This SRM can also be used for quality assurance when assigning values to in-house reference materials. The SRM is a creamy peanut butter prepared by a manufacturer of peanut butter products. A unit of SRM 2387 consists of three jars of peanut butter containing 170 g each.

Tags: Standard Reference Material,SRM,SRM 2387,peanut butter,certified values,reference values,food,nutrition,Food and Nutrition,

Modified: 2024-02-22

Views: 0

SRM 3239 Isoflavones Calibration Solution

Data provided by  National Institute of Standards and Technology

SRM 3239 Isoflavones Calibration Solution - This Standard Reference Material (SRM) is intended primarily for use in calibration of instruments and techniques used for the determination of isoflavones. SRM 3239 consists of two solutions containing isoflavones at levels that reflect the mass fraction ratios found in soy products. This data is public in the Certificate of Analysis for this material.

Tags: Standard Reference Material,SRM,SRM 3239,certified values,nutrition,dietary supplements,isoflavones,Food and Nutrition,

Modified: 2024-02-22

Views: 0

Certified values of iodine in CRMs of food matrices in mg/kg units. The uncertainties are expanded uncertainties at approximately 95% confidence.

Data provided by  National Institute of Standards and Technology

A comparison of the expanded uncertainty for certified values of iodine in food matrix CRMs. The CRMS were found by searching The European Virtual Institute for Speciation Analysis (EVISA) database using the terms "Iodine" and "Certified" in the Material category. The uncertainties are expanded uncertainties at approximately 95% confidence.

Tags: food,nutrition,dietary supplements,Standard Reference materials,reference materials,SRM,RM,Food and Nutrition,

Modified: 2024-02-22

Views: 0

NIST Atomic Spectra Database - SRD 78

Data provided by  National Institute of Standards and Technology

This database provides access and search capability for NIST critically evaluated data on atomic energy levels, wavelengths, and transition probabilities that are reasonably up-to-date. The Atomic Spectroscopy Data Center has carried out these critical compilations. The Data Center is located in the Physical Measurement Laboratory at the National Institute of Standards and Technology (NIST).

Tags: cesium,chlorine,chromium,cobalt,columbium,copernicium,copper,curium,darmstadtium,database,deuterium,doubly-charged,dubnium,dysprosium,einsteinium,element,energy levels,erbium,europium,fermium,flerovium,fluorine,francium,gadolinium,gallium,germanium,gold,ground states,hafnium,hassium,helium,holmium,hydrogen,indium,iodine,ionization potentials,ionization-energies,ionization-limits,ionized-atoms,iridium,iron,mendelevium,mercury,molybdenum,multiply-charged,neodymium,neon,neptunium,neutral,nickel,niobium,nitrogen,nobelium,osmium,oxygen,palladium,phosphorus,platinum,plutonium,polonium,potassium,praseodymium,promethium,protactinium,quadruply-charged,radium,rhenium,rhodium,roentgenium,rubidium,ruthenium,rutherfordium,samarium,scandium,seaborgium,selenium,silicium,silicon,silver,singly-charged,sodium,spectra,spectral lines,spectroscopy,spectrum,strontium,sulfur,sulphur,tantalum,technetium,tellurium,terbium,thallium,thorium,thulium,tin,titanium,transition probabilities,triply-charged,tritium,tungsten,ununbium,ununhexium,ununoctium,ununpentium,ununquadium,ununseptium,ununtrium,unununium,uranium,vanadium,wavelengths,xenon,ytterbium,yttrium,zinc,zirconium,krypton,kurchatovium,lawrencium,lanthanum,lead,lithium,livermorium,lutetium,magnesium,manganese,meitnerium,Atomic,Atomic Spectroscopy,Radon,actinium,aluminium,aluminum,americium,antimony,argon,arsenic,astatine,atom,atomic physics,atomic property,atomic-ions,barium,berkelium,beryllium,bismuth,bohrium,boron,bromine,cadmium,calcium,californium,carbon,cerium,

Modified: 2024-02-22

Views: 0

NIST-LANL Lanthanide/Actinide Opacity Database

Data provided by  National Institute of Standards and Technology

The database contains radiative line-binned opacities for lanthanides (atomic number 57<=Z<=70) and actinides (atomic number 89<=Z<=102) which are of paramount importance for simulation of light curves and spectra produced by kilonovae. The opacities were calculated by the LANL group under the assumption of local thermodynamic equilibrium. The temperature grid cover the range from 0.01 eV to 5.0 eV while the mass density grid covers 16 orders of magnitude. The database provide search and selection tools along with graphical and tabular outputs.

Tags: kilonova,lanthanides,opacity,radiation,neutron star merger,atomic physics,actinides,

Modified: 2024-02-22

Views: 0

Rydberg state engineering: A comparison of tuning schemes for continuous frequency sensing

Data provided by  National Institute of Standards and Technology

On-resonance Rydberg atom-based radio-frequency (RF) electric field sensing methods remain limited by the narrow frequency signal detection bands available by resonant transitions. The use ofan additional RF tuner field to dress or shift a target Rydberg state can be used to return a detuned signal field to resonance and thus dramatically extend the frequency range available for resonantsensing.

Tags: Rydberg atoms,atomic physics,receivers,fields strength,electric field,volts/meter,

Modified: 2024-02-22

Views: 0

Modeling Line Broadening and Distortion Due to Inhomogeneous Fields for Rydberg Electrometry

Data provided by  National Institute of Standards and Technology

This set corresponds to a (pending) publication, where we attempt to model spectral features appearing in the lab by calculating many segments of an inhomogeneous field. Every data set here is a transmission value, either normalized to 1 in modeled data, or an arbitrary-scaled voltage reading from a photodiode onto an oscilloscope. These are given in scans over coupling photon detuning, delta_C, which is divided by 2 pi, and given in MHz. Arrays are scans over delta_C, and position/fieldstrength, for figure 3.

Tags: Rydberg atoms,atomic physics,receivers,fields strength,electric field,volts/meter,

Modified: 2024-02-22

Views: 0

Phase-Resolved Rydberg Atom Field Sensing using Quantum Interferometry

Data provided by  National Institute of Standards and Technology

Although Rydberg atom-based electric field sensing provides key advantages over traditional antenna-based detection, it remains limited by the need for a local oscillator (LO) for low-field and phase resolved detection. In this work, we demonstrate the general applicability of closed-loop quantum interferometric schemes for Rydberg field sensing, which eliminate the need for an LO. We reveal that the quantum-interferometrically defined phase and frequency of our scheme provides an internal reference that enables LO-free full 360 degree-resolved phase sensitivity.

Tags: Rydberg atoms,atomic physics,receivers,fields strength,electric field,volts/meter,

Modified: 2024-02-22

Views: 0

Data for the article " Pseudo-resonant Detection of `Low Frequency' VHF Electric Fields via Rabi Matching with Autler-Townes Splitting in Rydberg Atoms"

Data provided by  National Institute of Standards and Technology

This dataset represents absorption/transmission spectra of resonant probe light power through a Rydberg atom vapor, subject to a simultaneous dressing field and a 'low frequency' field. Data is taken as an oscilloscope average of 5 photodiode voltage traces, with frequency offsets given by a simultaneous reference cell (not included). Some data are given as 2-D arrays, with axes of laser detuning across a waterfall of field strength. Some data represents theory eigen-energies of the system, for comparison. This paper will be submitted to Physical Review Letters.

Tags: Rydberg atoms,atomic physics,receivers,fields strength,electric field,volts/meter,

Modified: 2024-02-22

Views: 0

Electric field inhomogeneity

Data provided by  National Institute of Standards and Technology

Measurement of the effect of electric field inhomogeneity on electromagnetically induced transparency in a waveguide-based cesium atomic vapor cell. Used for the figure for the Photonics West 2023 manuscript.

Tags: Rydberg atoms,atomic physics,receivers,fields strength,electric field,volts/meter,

Modified: 2024-02-22

Views: 0